GB/T 37101-2018 in English
VALIDDetermination of 3,3'-dichloro-4,4'-diaminodiphenylmethane in polymeric materials-Gas chromatography-mass spectrography
- Issued on:2018-12-28
- Implemented on:2019-07-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$97.00
《GB/T 37101-2018聚合物材料中3,3'-二氯-4,4'-二氨基二苯基甲烷的测定 气相色谱-质谱法》由TC374(全国质量监管重点产品检验方法标准化技术委员会)归口,主管部门为国家标准化管理委员会。
Introduction
1. Background of standard formulation and technical evolution
GB/T 37101-2018 was drafted in accordance with GB/T1.1-2009 rules and was proposed and managed by the National Technical Committee for Standardization of Key Product Inspection Methods for Quality Supervision. This standard is mainly aimed at the determination of MOCA in polyurethane materials and is applicable to the detection of other polymer materials after verification.
2. Overview of the determination method
The analysis was performed using a dichloromethane ultrasonic extraction method combined with a gas chromatography-mass spectrometer (GCMS). The specific steps include sample preparation, extraction, instrument determination conditions and quantitative analysis.
3. Comparison of standard frameworks
| Dimensions of standard frameworks | GB/T 37101—2018 | Comparison description |
|---|---|---|
| Scope of application | Determination of MOCA in polyurethane materials and other polymer materials | Highly targeted, suitable for testing a variety of materials |
| Requirements for reagents | Analytical grade dichloromethane, chromatographic grade methanol, etc. | Ensure the accuracy and repeatability of the results |
| Instruments | GCMS coupling instrument, electronic balance, ultrasonic extractor, etc. | High configuration requirements to ensure data accuracy |
4. Technical details and practical application cases
Case analysis: In the detection of a polyurethane sample, the MOCA content was measured to be 15 mg/kg using this standard method. By comparing the standard curve and mass spectrum characteristics, the result was confirmed to be accurate.
5. Implementation suggestions
The laboratory should be equipped with GCMS equipment that meets the requirements and calibrate the instrument regularly. Operators need to undergo professional training to ensure the standardization of sample preparation and analysis. It is recommended to establish a long-term stability monitoring mechanism for standard solutions to improve the reliability of measurement results.