GB/T 37185-2018 in English
VALIDGas analysis--Determination of indoor harmful volatile organic compounds--"SUMMA canister and silonite tube" and chromatography/mass spectrometry(GC/MS)
- Issued on:2018-12-28
- Implemented on:2019-11-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$214.00
《GB/T 37185-2018气体分析 室内挥发性有害有机物的测定 “SUMMA罐-硅烷化管”采样气相色谱/质谱联用(GC/MS)法》由TC206(全国气体标准化技术委员会)归口,TC206SC1(全国气体标准化技术委员会气体分析分会)执行,主管部门为中国石油和化学工业联合会。
Introduction
Introduction
This standard (GB/T 37185-2018) specifies the determination method of volatile hazardous organic compounds in indoor air, using SUMMA tanks and silanized tube sampling combined with gas chromatography/mass spectrometry (GC/MS) technology. This method is suitable for the detection of volatile organic compounds in places such as residences, office buildings, and environmental test chambers.
Method principle
Indoor air samples are collected through stainless steel tanks with inert inner walls, and cold trap capture concentration and heating desorption technology are used. After the samples are separated by capillary chromatographic columns, they are qualitatively and quantitatively analyzed by mass spectrometry detectors. The identification of the target is completed by comparing with the standard mass spectrum database and retention time.
Reagents and Materials
| Project | Requirements |
|---|---|
| Standard Gas | Contains 19 kinds of volatile organic compounds, and the expanded uncertainty is less than 5% when the mole fraction is $1\mu\mathrm{mol/mol}$ |
| High-purity Helium/Nitrogen | The purity is not less than 99.999%, in line with the requirements of GB/T 4844 and GB/T 8979 |
| Liquid Nitrogen | Meets the technical requirements of GB/T 3864, used for sample storage and processing |
Instruments and Equipment
The main instruments include:
- Gas pre-concentration system: used for sample capture and concentration.
- Gas chromatograph/mass spectrometer (GC/MS): with electronic flow controller, program temperature rise function and full scan/selected ion scan mode.
- Capillary column: 6% cyanopropylbenzene/94% methylsiloxane, 60 meters long, 0.32 mm inner diameter, 1.8 microns film thickness.
Sample collection and storage
Sample collection adopts two methods: instantaneous sampling and constant flow sampling:
- Instantaneous sampling: bring the SUMMA tank to the sampling point, and complete the sampling in about 30 seconds after opening the valve.
- Constant flow sampling: Set a constant flow rate and start sampling until the scheduled time ends.
Samples must be stored at room temperature. Formaldehyde analysis must be completed within 7 days, and other components must be completed within 15 days.
Analysis steps
| Pre-concentration system control conditions | |||
|---|---|---|---|
| First-level cold trap unit | Trapping temperature: -40℃ | Desorption temperature: 10℃ | Baking time: 5 minutes |
| Secondary cold trap unit | Trapping temperature: -60℃ | Desorption temperature: 230℃ | Baking time: 5 minutes |
Result calculation and presentation
Quantitative analysis is based on the calibration curve. The mole fraction of the target compound is calculated by the peak area and converted into the mass concentration under standard conditions. Qualitative analysis is completed using relative retention time and mass spectrum database matching.
Quality assurance and control
- Parallel sample determination: one parallel sample is analyzed for every 10 samples or each batch, and the relative deviation of the target object is no more than 30%.
- Calibration curve: at least 5 concentration points, and the linear correlation coefficient is not less than 0.995.
Implementation suggestions
To ensure the effective implementation of the standard:
- The laboratory should be equipped with advanced GC/MS equipment and calibrated regularly.
- Operators must undergo professional training and be familiar with the specifications for the use of SUMMA tanks and silanized tubes.
- In data processing, it is recommended to use the NIST database for mass spectrum matching.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 34226-2017 in English
Technical guideline for formic acid preparation from yellow phosphorus tail gas
2017-09-07 -

GB/T 34710.1-2017 in English
Classification of the mixture gas―Part 1:Toxic classification
2017-11-01 -

GB/T 37182-2018 in English
Gas analysis--Gas chromatograph with plasma emission detector
2018-12-28 -

GB/T 33318-2016 in English
Gas analysis--Determination of sulfide--Gas chromatography with sulfur chemiluminescence
2016-12-13 -

GB/T 26073-2010 in English
Safety guideline for the evaluation of toxic and flammable gas detection systems
2011-01-10 -

GB/T 6285-2016 in English
Determination of trace oxygen in gases―Electrochemical method
2016-12-13 -

GB/T 5274.1-2018 in English
Gas analysis—Preparation of calibration gas mixtures—Part 1:Gravimetric method for class Ⅰ mixtures
2018-09-17 -

GB/T 26570.1-2011 in English
Determination of particle in gases—Light-scattering method—Part 1:Determination of particle in pipeline gases
2011-06-16 -

GB/T 35860-2018 in English
Gas analysis—Contents of certificates for calibration gas mixtures
2018-02-06