GB/T 37268-2018 in English
VALIDPV shading panel of building
- Issued on:2018-12-28
- Implemented on:2019-11-01
- File Format:PDF
- Delivery:Within 1 day
$171.00
《GB/T 37268-2018建筑用光伏遮阳板》由TC454(全国建筑构配件标准化技术委员会)归口,主管部门为住房和城乡建设部。
Introduction
1. Standard Overview and Background
GB/T 37268-2018 "Photovoltaic Sunshades for Buildings" was proposed by the Ministry of Housing and Urban-Rural Development of the People's Republic of China, and aims to standardize the design, production and application of solar panels with photovoltaic power generation functions for buildings. This standard fills the technical gap in the field of building photovoltaic sunshades and promotes the development of building energy conservation and renewable energy utilization.
2. Comparison of standard frameworks
| Standard dimensions | GB/T 37268—2018 | JG/T 482—2018 | Difference analysis |
|---|---|---|---|
| Definition of terms | Detailed provisions on the composition and classification of photovoltaic sunshades | Unspecified the types and operation methods of photovoltaic modules | Supplemented the definitions of thin-film photovoltaic modules and movable/fixed types |
| Performance indicators | New requirements for power generation and hot spot durability | Only covers basic mechanical properties | Expanded electrical safety and lightning protection performance requirements |
| Test methods | Detailed test procedures and parameters are provided | Power generation test methods are not included | Power generation test specifications in Appendix A are added |
3. Technical requirements and performance indicators
3.1 Technical requirements for photovoltaic modules
Photovoltaic modules must comply with the provisions of GB/T 9535 and GB/T 18911 to ensure their stability and reliability in different environments. For example, crystalline silicon photovoltaic modules should have high conversion efficiency, while thin-film photovoltaic modules must maintain performance under bending conditions.
3.2 Structural strength of blades and brackets
The blades are made of high-strength aluminum alloy profiles (GB/T 5237), and the surface needs to be anodized to improve corrosion resistance and durability. The bracket part is made of low carbon steel or aluminum alloy to ensure its bearing capacity and wind pressure resistance.
3.3 Drive device and safety protection
The drive device should use a low-speed motor (JG/T 276) and be equipped with a temperature protection device to prevent overheating damage. In addition, the junction box needs to be installed with a bypass diode to avoid power loss caused by short circuit of the component series circuit.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 36140-2018 in English
Technical requirements for assembled insulation combination wall composite by glass fiber reinforced inorganic materials
2018-05-14 -

GB/T 30593-2025 in English
External wall interior insulation composite panel system
2025-10-31 -

GB/T 43496-2023 in English
Test method of thermal cycling and condensation resistance of curtain walls
2023-12-28 -

GB/T 40715-2021 in English
Specification of precast concrete curtain wall panel
2021-10-11