Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
inorganic composite insulation wall assembled glass fiber assembled insulation combination wall composite insulation wall composite insulation wall panels thermal noise noise vertical groove square back-up board insulation pipes
GB/T 36140-2018 in English

GB/T 36140-2018 in English

VALID

Technical requirements for assembled insulation combination wall composite by glass fiber reinforced inorganic materials

  • Issued on:2018-05-14
  • Implemented on:2019-04-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $370.00
$359.00
Standard No: GB/T 36140-2018
Document status: VALID
Title in English: Technical requirements for assembled insulation combination wall composite by glass fiber reinforced inorganic materials
Title in Chinese: 装配式玻纤增强无机材料复合保温墙体技术要求
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 5 business days
Issued on: 2018-05-14
Implemented on: 2019-04-01
ICS Classification: 91.060.10-Walls. Partitions. Facades
Chinese Classification: P32-Building construction and decoration engineering
Professional Classification: GB-National Standard
Related Keywords: inorganic composite insulation wall
assembled glass fiber
assembled insulation combination wall
composite insulation wall
composite insulation wall panels
Related Topics: glassfiber
GB/T 36140-2018
Inorganic High Temperature Materials
insulation wall
GB/T36140-2018
Inorganic constant temperature material
gb/t36140
gb/t+36140
GBT36140
GB/T 36140-2018
Inorganic exterior wall insulation materials
Assembled
Specification requirements for thermal insulation materials
Composite material coating technology
Glass fiber insulation felt product requirements

《GB/T 36140-2018装配式玻纤增强无机材料复合保温墙体技术要求》由TC454(全国建筑构配件标准化技术委员会)归口,主管部门为住房和城乡建设部。


Introduction

1. Overview and scope of application

GB/T 36140-2018 "Technical requirements for assembled glass fiber reinforced inorganic material composite insulation wall" mainly stipulates the technical requirements for assembled glass fiber reinforced inorganic material composite insulation wall panels, which is applicable to non-load-bearing exterior walls and interior partitions in general industrial and civil buildings.

2. Comparison of standard frameworks

Standard dimensions Technical requirements Test methods
Appearance quality The board surface must not have defects such as missing ribs, flash and burrs Visual inspection and measuring tools should be used in combination
Dimensional tolerance The width tolerance is ±4mm (E)/±2mm (P), and the height tolerance is ±3mm (E)/±5mm (P) Measured in accordance with GB/T 30100-2013 standard
Performance indicators Impact resistance: E≥900N·m, P≥147N·m; airborne sound insulation performance: Rw+C≥45dB (E), ≥30dB (P) Tested in accordance with GB/T 19889.3 and GB/T 31433 standards

3. Technical requirements interpretation

3.1 Material selection and performance

The glass fiber reinforced inorganic composite insulation wall is composed of glass fiber reinforced inorganic board as the surface layer and the sandwich layer is composed of thermal insulation material. The selection of materials must comply with the requirements of GB/T 5464 "Test method for non-combustibility of building materials" and JG/T 396-2012 "Non-load-bearing fiber reinforced cement board for exterior wall".

3.2 Construction and installation specifications

Case analysis: In prefabricated buildings, when light steel keels are used as supporting structures, it is necessary to ensure that the joints of the wall panels are well sealed to meet the requirements of air tightness and water tightness. It is recommended to use silicone building sealant for sealing.

4. Implementation suggestions

In actual applications, appropriate insulation materials (such as EPS, RW, etc.) should be selected according to the design requirements of the building. During the construction process, quality control must be strictly carried out in accordance with standard dimensional deviations and performance indicators, especially in terms of fire resistance and wind pressure resistance, to ensure the safety and durability of the building.

Sample only — not a preview of GB/T 36140-2018
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend