Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
water supply protection high voltage system protection must comply rebuilt water supply distribution system rotating motor protection water purification plants thermoplastic elastomers nomenclature spacecraft dimensions qualification-level test requirements assessment public building project introduction gb/t
GB/T 39437-2020 in English

GB/T 39437-2020 in English

VALID

Technical specification for lightning protection of water supply and drainage system

  • Issued on:2020-11-19
  • Implemented on:2021-06-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $490.00
$476.00
Standard No: GB/T 39437-2020
Document status: VALID
Title in English: Technical specification for lightning protection of water supply and drainage system
Title in Chinese: 供排水系统防雷技术规范
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 5 business days
Issued on: 2020-11-19
Implemented on: 2021-06-01
Professional Classification: GB-National Standard
Related Keywords: water supply
protection high voltage system protection must comply
rebuilt water supply
distribution system rotating motor protection
water purification plants
Related Topics: water system
thunder
drainage system
Ray+
lightning protection
drainage system
water system
Power distribution system lightning protection
GBT39437
GB/T 39437-2020
Lightning Protection Technology of Communication Engineering Power System
Water supply and drainage technology

《GB/T 39437-2020供排水系统防雷技术规范》由416(中国气象局)归口,TC345(全国气象防灾减灾标准化技术委员会)执行,主管部门为中国气象局。


Introduction

Analysis of the core content of the standard

1. Scope of application and basic requirements

This standard applies to all types of newly built, expanded and rebuilt water supply and drainage systems, including:

  • water purification plants, wastewater treatment plants buildings and facilities
  • Lightning protection for pumping stations and pipe network systems
  • Supporting power supply and distribution, and automation control systems

Lightning protection categoriesClassification conditionsExamples
Category 2Class I/II water plants with an estimated lightning strike frequency of >0.05 times/yearMain water plants in large cities
Category 3Other water supply and drainage buildingsSmall sewage treatment plants

2. Key technical points of protection

High voltage system protection

Must comply with the requirements of GB/T50064-2014, and the arrester selection should meet the following requirements:

  1. Metal oxide arresters are used in the distribution system
  2. Rotating motor protection needs to consider steep wave impact

SPD hierarchical configuration

Installation locationSPD typeTypical parameters
Main distribution box (LPZ0/1)T1 categoryIimp≥12.5kA(Class II)
Distribution box (LPZ1/2)T2 categoryIn≥10kA
Equipment terminalT3 categoryUc≥1.15U0

3. Protection requirements for special places

Biogas system

  • When the tank wall thickness is ≥4mm, the lightning arrester can be omitted
  • Flange jumper resistance ≤ 0.03Ω
  • Must use explosion-proof SPD

Automation instrument protection

Equipment such as electromagnetic flowmeters must take the following measures

  1. Double-end grounding of the metal casing
  2. Install Class D1 SPD on the signal line
  3. Use photoelectric isolator (withstand voltage ≥ 10kV)

4. Inspection and maintenance specifications

Inspection itemsPeriodBased on standards
Ground resistance testYearlyGB/T21431
SPD status checkBefore the thunderstorm seasonGB/T18802.12
Hazardous chemicals area inspectionEvery six monthsArticle 9.2

Note: A lightning protection safety emergency plan should be established, and a disaster analysis should be conducted after a lightning strike.

Technology evolution analysis

Main improvements of this standard compared to the old version:

  • Added Industrial control system room protection requirements
  • Detailed SPD installation specifications in TN-S system
  • Introduced advanced technologies such as Kevin wiring method