《GB/T 40259-2021综采工作面支护质量检测技术条件》由603(中国煤炭工业协会)归口,主管部门为中国煤炭工业协会。
Introduction
Analysis of the core content of the standard
This standard specifies the full-process technical requirements for quality inspection of support for fully mechanized mining working faces, including key technical indicators such as sensor accuracy (inclination ±0.1°, pressure ±0.1MPa), system stability (7 days of continuous operation), and explosion-proof grade (GB 3836 series).
Comparison of technical frameworks
| Dimensions | Requirements of this standard | General requirements of the industry |
|---|---|---|
| Detection accuracy | ±0.1° (inclination) | ±0.5° |
| Environmental adaptability | -40℃~60℃ storage | -20℃~50℃ |
| Data transmission | WirelessMulti-function display terminal Distance ≥50m | 30m |
Analysis of key technologies
Support detection system architecture
The system consists of inclination sensor, pressure sensor, multi-function display terminal, etc., and realizes data collection through wireless/wired hybrid networking. Typical application case: After adopting this system in a certain mining area, the accident rate of support toppling was reduced by 62%.
Explosion-proof performance requirements
It is necessary to meet GB 3836.1~4 and GB 3836.9 standards at the same time, including the triple protection mechanism of flameproof enclosure "d", increased safety type "e", and intrinsic safety type "i".
Standard evolution background
With the intelligent development of fully mechanized mining working faces, traditional manual detection methods can no longer meet the accuracy requirements. This standard incorporates wireless sensor network technology into the specification for the first time, solving the problem of coordinated monitoring of hydraulic support groups.
Implementation suggestions
- Preferably use tilt sensors with a dual-axis ±90° range
- A 72-hour stability pre-test is required when the system is deployed
- Regularly calibrate the overload protection function of the pressure sensor (2 times the full scale)

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB 18671-2009/XG1-2023 in English
Intravenous needles for single use, includes Amendment 1
2023-05-23 -

GB 35848-2024 in English
Commercial gas-burning appliance
2024-04-29 -

GB/T 18257-2021 in English
Hot-face identification marking of refractory bricks for use in rotary kilns
2021-10-11 -

GB/T 19142-2016 in English
Packaging for export commodity—General rule
2016-02-24 -

GB/T 12959-2024 in English
Test methods for heat of hydration of cement
2024-04-25 -

GB 16170-1996 in English
Limits of noise emitted by stationary road vehicles
1996-03-07 -

GB/T 30693-2014 in English
Measurement of water-contact angle of plastic films
2014-12-31 -

GB/T 14392.3-2023 in English
Layout key for international trade documents—Part 3:Application guidelines
2023-12-28 -

GB/T 17699.1-2024 in English
Electronic data interchange for administration, commerce and transport(EDIFACT) —Part 1:Data element directory
2024-05-28 -

GB/T 2830-1981 in English
Rolled-up punched paper tape for data interchange--General requirements
-