Introduction
Analysis of the core content of the standard
This standard specifies a system of detection methods for 9 types of organic/inorganic solvent residues in solution-spun chemical fibers, including:
- 4 types of chromatographic detection techniques: GC-MS, LC-MS/MS, headspace gas chromatography, spectrophotometry
- 2 types of titration methods: complexometric titration (sodium thiocyanate), acid-base titration (concentrated sulfuric acid)
- 7 key organic solvents: DMF, DMAC, DMSO, NMP, etc. (see Appendix A)
Comparative analysis of detection methods
| Method | Applicable solvent | Detection limit (mg/kg) | Precision | Technical Features |
|---|---|---|---|---|
| GC-MS | 6 types including DMF/DMAC | 5.0 | RSD≤15% | Arbitration method, multi-component simultaneous detection |
| LC-MS/MS | NMMO and its decomposition products | 0.5 | RSD≤10% | High sensitivity, strong specificity |
| Spectrophotometry | DMF/DMAC/DMSO | 20 | - | The equipment is simple, but attention should be paid to interference |
Key technical points
1. Sample pretreatment
Different methods use different extraction schemes:
- Organic solvent: 70℃ methanol ultrasonic extraction for 60min (GC-MS)
- NMMO system: room temperature water extraction (LC-MS/MS)
- Ultra-high molecular weight polyethylene fiber: n-hexane Soxhlet extraction (Appendix C)
2. Instrument parameter optimization
The standard provides key parameter reference:
- GC-MS: DB-WAX column, 50-250℃ programmed temperature
- LC-MS/MS: C18 column, acetonitrile-0.1% formic acid water gradient elution
Implementation recommendations
- Method selection: Prioritize the fiber-solvent correspondence table in Appendix D
- Quality control: Each batch of samples needs to be subjected to a blank test and spike recovery
- Data verification: When the difference between the spectrophotometric method and the GC-MS result is greater than 20%, the GC-MS shall prevail
- Special treatment: The detection of decalin needs to distinguish between cis/trans isomers (see clause 5.5)
Background of standard evolution
This standard integrates the original industry detection methods (such as FZ/T 50057-2016), major technological breakthroughs:
- New LC-MS/MS method for detecting NMMO decomposition products
- Specified for the first time a dedicated test scheme for ultra-high molecular weight polyethylene fibers (Appendix B/C)
- Unified calculation methods for residual solvent limits for various types of fibers

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 40351-2021 in English
Ecological technical requirements for recycled Poly(ethylene terephthalate) fiber
2021-08-20 -

GB/T 32151.47-2024 in English
Requirements of the greenhouse gas emission accounting and reporting—Part 47:Chemical fiber production enterprise
2024-10-26 -

GB/T 36020-2018 in English
Man-made fiber—Test method of dipped cord
2018-03-15