Introduction
1. Standard Overview
This standard (GB/T 42208-2022) specifies the method for measuring the particle size of nanoparticles in multiphase systems using the transmission electron microscope image method, which is applicable to the measurement of nanoparticles in solid phases, colloids and biological tissues. The standard elaborates on sample preparation, test steps, particle size measurement and uncertainty analysis.
2. Background of Standard Formulation
With the rapid development of nanotechnology, nanomaterials have been widely used in many fields. However, the particle size measurement of nanoparticles has always been a difficult point, especially in multiphase systems. This standard solves this problem through the transmission electron microscope (TEM) image method, providing unified technical specifications for scientific research and industrial applications.
3. Comparison of standard frameworks
| Standard dimensions | GB/T 42208-2022 | Comparison of international standards |
|---|---|---|
| Scope of application | Measurement of nanoparticles in multiphase systems | ISO/TS 23096:2017 (Nanotechnology - Determination of particle size distribution) |
| Core methods | Transmission electron microscopy imaging method | Small angle X-ray scattering (SAXS), dynamic light scattering (DLS) |
| Measurement accuracy | ±5% (particle size range 1-100nm) | ±10% (SAXS method), ±8% (DLS method) |
4. Implementation Suggestions
4.1 Notes on sample preparation
During the sample preparation process, pay attention to the following points:
- Ensure that the sample structure maintains the original state of the multiphase system;
- The thickness of the transmission electron microscope sample is generally 50-100nm;
- Avoid oxidation and contamination, and store in a dry place.
4.2 Recommendations for image acquisition and processing
During image acquisition and processing, the following steps are recommended:
- Choose appropriate imaging technology (bright field, dark field, or high-angle annular dark field) according to the sample type;
- Ensure image clarity and contrast, and take multiple images of different areas;
- Use automated thresholding to reduce user bias and improve measurement accuracy.