| Standard No: | GB/T 43552-2023 |
| Document status: | VALID |
| Title in English: | Comfort fans and regulators for household and similar purposes—Methods for measuring performance |
| Title in Chinese: | 家用和类似用途舒适风扇及其调速器 性能测试方法 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 5 business days |
| Issued on: | 2023-12-28 |
| Implemented on: | 2024-07-01 |
| ICS Classification: | 23.120-Ventilators. Fans. Air-conditioners |
| Chinese Classification: | K65-Other electric appliances |
| Professional Classification: | GB-National Standard |
| Related Keywords: | comfort fan fan
louvre fan comfort fan table fan comfort fan pedestal fan comfort fan bladeless fan comfort fan |
| Related Topics: | Applicability of method
Suitability for use Purpose and method of use Lipid determination methods and their scope of application Method for correcting results of fan anemometer Several production methods and their applications Category 1 reagents are applicable gb/t 43552-2023 |
《GB/T 43552-2023家用和类似用途舒适风扇及其调速器 性能测试方法》由TC46(全国家用电器标准化技术委员会)归口,TC46SC4(全国家用电器标准化技术委员会通风器具分会)执行,主管部门为中国轻工业联合会。
Comfort fans and regulators for household and similar purposes - Methods for measuring performance
1 Scope
This document specifies the performance-measuring methods of comfort fans and regulators for household and similar purposes, including conventional fans, tower fans and bladeless fans, their rated voltage being not more than 250 V for single-phase fans and 480 V for other fans, and their rated power input being less than 1 25 W.
Note 1: According to the testing method, the comfort fans are classified into two groups:
——pedestal fans, table fans, wall fans, louvre fans, tower fans, bladeless fans;
——ceiling fans.
Wherever applicable, the term "fan" used in this document includes its associated regulator, if any.
Note 2: This document does not apply to
——safety of electric fans for household and similar purposes (GB 4706.27);
——performance of ventilating fans (IEC 60665);
——electromagnetic compatibility requirements for household appliances, electric tools and similar apparatus - Part 1: Emission (GB GB 4343.1)
——electromagnetic compatibility requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity (GB/T 4343.2)
——electromagnetic compatibility - Limits - Part 1: Limits for harmonic current emissions (equipment input current ≤16 A per phase) (GB 17625.1)
——electromagnetic compatibility (EMC) - Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection (GB/T 17625.2)
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60704-2-7 Household and similar electrical appliances - Test code for the determination of airborne acoustical noise – Part 2-7: Particular requirements for fans
IEC 62301 Household electrical appliances – Measurement of standby power
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
comfort fan
fan primarily designed for creating air movement around or on part of a human body for personal cooling comfort, including fans that can perform additional functionalities such as
Lighting
Note: A comfort fan is hereinafter also referred to by the term "fan".
3.2
conventional fan
comfort fan with a propeller having two or more blades, with free inlet and outlet of air
3.3
tower fan
comfort fan for use on the floor having a vertically elongated design of the cross-flow type, tangential type, centrifugal type or impeller type with a free inlet and outlet of air
3.4
bladeless fan
comfort fan of any type that is not fitted with a propeller
3.5
ceiling fan
conventional fan provided with a device for suspension from the ceiling of a room so that the blades rotate in a horizontal plane with the diameter of the blade not larger than 1800 mm
3.6
table fan
comfort fan intended for use on a table
Note: Table fans have a maximum adjustable or non-adjustable height of less than 1 200 mm.
3.7
pedestal fan
comfort fan mounted on a pedestal of fixed or variable height
Note: Pedestal fans have a minimum adjustable height or non-adjustable height equal to or greater than 1 200 mm.
3.8
wall bracket fan
comfort fan for mounting on the wall
3.9
ceiling bracket fan
comfort fan for mounting on the ceiling
3.10
louvre fan
comfort fan having moving louvre which provides a continuously changing multi-directional air flow
3.11
rated fan flow rate
air flow rate assigned to the fan by the manufacturer
Note: The rated fan flow rate is expressed in m3 /min.
3.12
service value
ratio of the calculated maximum fan flow rate [m3 /min] to the measured fan power input [W]
Note: The service value is also known as the "coefficient of performance (COP)".
3.13
fan power input
power input of the fan operating at its maximum flow rate, measured with the oscillation
mechanism and the moving louvre, if any, turned off
Note: The power inputs for other functions, such as lighting are not included.
3.14
rated voltage
voltage assigned to the fan by the manufacturer
3.15
rated frequency
frequency assigned to the fan by the manufacturer
3.16
maximum fan flow rate
air flow rate of the comfort fan at its maximum setting [m3 /min], measured at the fan outlet with the oscillating mechanism and the moving louvre, if any, turned off
3.17
oscillating mechanism
capability of the comfort fan to automatically vary the direction of the air flow while the fan is operating
3.18
fan sound power level
A-weighted sound power level of the comfort fan while providing the maximum fan flow rate, measured at the outlet side
3.19
moving louvre
grill provided at the air outlet of louvre fans, which is used to control the direction of the air
flow by its rotation or position
3.20
equivalent sweep size diameter of bladeless fan
value obtained by dividing the perimeter of the bladeless fan air outlet by 3,1 4.
Note: The perimeter is obtained by measuring the length of the rope that wraps along the complete enclosure of the bladeless fan's air outlet.
4 Information provision
Manufacturers shall provide the following information in the instructions:
a) rated fan flow rate m3 /min (rounded to one decimal place);
b) service value (m3 /min)/W (rounded to one decimal place);
c) standby power consumption W (rounded to one decimal place);
d) sound power level dB(A).