GB/T 45168-2024 in English
VALIDDetermination of chromium picolinate in health foods
- Issued on:2024-12-31
- Implemented on:2025-07-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
Price(USD):
$210.00
$204.00
$204.00
《GB/T 45168-2024保健食品中吡啶甲酸铬的测定》由TC466(全国特殊食品标准化技术委员会)归口,主管部门为市场监管总局(特殊食品)。
Introduction
1. Analysis of standard formulation background and technological evolution
GB/T45168-2024 standard is the latest revised version of the determination method for chromium picolinate in health foods, replacing the previous GB/T5009.195-2003 standard. The main revisions include:
- The scope of application of the document has been changed
- The preparation process of the standard solution has been optimized
- The sample preparation step has been added
- The chromatographic reference conditions have been updated
- The precision requirements of the method have been improved
2. Standard framework comparison table
| Standard dimensions | Old version GB/T5009.195—2003 | New version GB/T45168-2024 |
|---|---|---|
| Scope of application | Limited to the determination of chromium picolinate in health foods | Extended to multiple dosage forms such as tablets and hard capsules |
| Extraction method | Specific extraction conditions are not specified | Specified ultrasonic extraction with 50% methanol solution |
| Chromatographic conditions | The stationary phase is C18 column, and the mobile phase is not specified in detail | Specified gradient elution conditions and detection wavelength of 264nm |
3. Interpretation of standard determination method
Sample preparation steps:
- Solid sample: Extract at fixed volume after high-speed pulverizer treatment
- Liquid sample: Vortex mixing and ultrasonic extraction for 10 minutes
- Chromatographic analysis after centrifugal filtration
Key points of HPLC:
- Use>C18 chromatographic column
- Gradient elution conditions: acetonitrile and potassium dihydrogen phosphate solution mixed in proportion
- Detection wavelength set to 264nm
4. Implementation suggestions
Laboratory precautions:
- Ensure instrument calibration, especially the wavelength accuracy of the UV detector
- Reagent purity must meet standard requirements
- Operate in strict accordance with chromatographic conditions to avoid deviation leading to result errors
Quality control suggestions:
- Check the standard curve regularly
- Use internal standard substances as quality control tools
- Keep the temperature and humidity of the laboratory environment stable
Sample only — not a preview of GB/T 45168-2024

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 23788-2026 in English
Determination of soybean isoflavones in health foods
2026-01-28 -

GB/T 22248-2025 in English
Determination of glycyrrhizic acid in health foods
2025-03-28