Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
air source heat pump packages hot water type steam type nominal cop water temperature ±0.1℃ steam type units carbon dioxide refrigerants introduction analysis zoological parks mineral oil content risk assessment practices
GB/T 45650-2025 in English

GB/T 45650-2025 in English

VALID

Air source heat pump packages with carbon dioxide as refrigerants

  • Issued on:2025-04-25
  • Implemented on:2025-11-01
  • File Format:PDF
  • Delivery:Via email within 8 business days
Price(USD): $600.00
$582.00

《GB/T 45650-2025二氧化碳空气源热泵机组》由TC238(全国冷冻空调设备标准化技术委员会)归口,主管部门为中国机械工业联合会。


Introduction

Analysis of the core content of the standard

Technical indicators Heating and hot water type Domestic hot water type Steam type
Nominal COP 2.20-2.50 2.70-3.20 1.50
Low temperature COP 1.70-2.20 - -
Applicable temperature range -35℃~21℃ -35℃~43℃ -25℃~43℃

Key technical requirements

Safety design: The unit must be equipped with a CO₂ safety pressure relief device, and the test pressure for the sealing of the refrigeration system pipeline is ≤133Pa. After the 24h salt spray test, the rust spot area of the electroplated parts is ≤1mm²/100cm².

Performance verification: The measured heating capacity must be ≥95% of the nominal value, and the power consumption must be ≤110% of the nominal value. The noise limit is controlled according to the heating capacity, such as ≤35kW units must be ≤66dB(A).


Test method innovation

  1. Liquid refrigerant method is used to measure heating capacity, and the accuracy requirement is water temperature ±0.1℃
  2. Steam type units use pipeline electric heater compensation method, SP value ≤500kW·h/t
  3. Defrost test requires cycle ≤ total duration 20%, and electric heating pipe direct heating defrost is prohibited

Implementation suggestions

1. Model matching: For ultra-low temperature environments, ultra-low ambient temperature units are preferred, and the nominal COP is allowed to be reduced by 0.3

2. Energy efficiency optimization: HSPF calculation uses Beijing/Mohe meteorological data, and it is recommended to clean the evaporator regularly to maintain a coefficient of ≥2.7

3. Safe operation and maintenance: R744 marking must be permanently maintained, and pressure vessels must be inspected annually according to TSG21 specifications

Sample only — not a preview of GB/T 45650-2025