Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
low-voltage switchgear 7251.1-2013 low-voltage switchgear controlgear assemblies construction sites acs annexes annex c dimethyl disulfide earth-moving machinery — plough bolt reduction index
GB/T 7251.4-2017 in English

GB/T 7251.4-2017 in English

VALID

Low-voltage switchgear and controlgear assemblies-Part 4:Particular requirements for assemblies for construction sites (ACS)

  • Issued on:2017-11-01
  • Implemented on:2018-05-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $310.00
$301.00
Standard No: GB/T 7251.4-2017
Document status: VALID
Title in English: Low-voltage switchgear and controlgear assemblies-Part 4:Particular requirements for assemblies for construction sites (ACS)
Title in Chinese: 低压成套开关设备和控制设备 第4部分:对建筑工地用成套设备(ACS)的特殊要求
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2017-11-01
Implemented on: 2018-05-01
Superseding: GB 7251.4-2006 Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)
Professional Classification: GB-National Standard
Related Keywords: low-voltage switchgear
7251.1-2013 low-voltage switchgear
controlgear assemblies
construction sites
acs annexes annex c
Related Topics: Pharmaceutical equipment
With complete set of equipment
Complete set of electrophoresis equipment
A complete set of carbon production equipment
Complete set of equipment
Total nitrogen complete set of equipment
Composition Testing Equipment
Complete equipment testing
AIS Package
Complete set of pharmaceutical equipment
Complete set of industrial equipment
Xishuang chemical complete equipment
High voltage switchgear
GB 7251.4
GB/T 7251.4
GB/T 7251.4-2006
GB/T 7251.4-2017
gb7251.1-2013 Low voltage complete switchgear
GB/T 7251.2-2023 Low-voltage complete sets of switchgear and control equipment Part 2: Complete sets of power switchgear and control equipment
Requirements for grounding of electrical equipment
Equipment completeness
Low voltage complete sets of equipment and control equipment circuit breakers
Acceptance of low voltage complete sets of switchgear
Air gap of low voltage complete equipment
Definition and characteristics of standard complete equipment
Low voltage switchgear implementation


1 Scope

Note: Throughout this part, the abbreviation ACS (ASSEMBLY for construction site, see 3.1.101) is used for a low-voltage switchgear and controlgear assembly intended for use on construction and similar sites.

This part of GB/T 7251 defines the specific requirements of ACS as follows:

——ASSEMBLIES for which the rated voltage does not exceed 1,000 V in case of a.c. or 1,500 V in case of d.c.;

——ASSEMBLIES where the nominal primary voltage and the nominal secondary voltage of transformers incorporated in ACS are within the limits specified above;

——ASSEMBLIES intended for use on construction sites, both indoors and outdoors, i.e. temporary places of work to which the public do not generally have access and where building construction ,installation, repairs, alteration or demolition of property (buildings) or civil engineering (public works) or excavation or any other similar operations are carried out;

——transportable (semi-fixed) or mobile ASSEMBLIES with enclosure.

The manufacture and/or assembly may be carried out other than by the original manufacturer.

This part does not apply to individual devices and self-contained components such as motor starters, fuse switches, electronic equipment, etc. which will comply with the relevant product standards.

This part does not apply to ASSEMBLIES for use in the administrative centres of construction sites (offices, cloakrooms, ASSEMBLY rooms, canteens, restaurants, dormitories, toilets, etc.).

Requirements for electrical protection provided by equipment manufactured according to this part are given in GB/T 16895.7.

2 Normative References

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

Chapter 2 of GB/T 7251.1-2013 is applicable except as follows

Addition:

GB/T 2423.19-2013 Environmental testing - Part 2: Test methods - Test Kc: Sulphur dioxide test for contacts and connections (IEC 60068-2-42: 2003, IDT)
GB/T 7251.1-2013 Low-voltage Switchgear and Controlgear Assemblies - Part 1: General Rules (IEC 61439-1: 2011, IDT)
GB/T 16895.7-2009 Low-voltage electrical installations - Part 7-704: Requirements for special installations or locations - Construction and demolition site installations (IEC 60364-7-704: 2005, IDT)
GB/T 17045-2008 Protection against electric shock - Common aspects for installation and equipment (IEC 61140: 2001, IDT)

Foreword i
1 Scope
2 Normative References
3 Terms and Definitions
4 Symbols and Abbreviations
5 Interface Characteristics
6 Information
7 Service Conditions
8 Constructional Requirements
9 Performance Requirements
10 Design Verification
11 Routine Verification
101 Particular Features of ACS
Annexes
Annex C (Informative) User Information Template
Annex D (Informative) Design Verification
Annex O (Informative) Guidance on Temperature Rise Verification
Annex P (Normative) Verification of the Short-circuit Withstand Strength of Busbar Structures by Comparison with a Tested Reference Design by Calculation
Annex AA (Informative) List of Notes Concerning Certain Countries
Annex BB (Void)
Annex CC (Informative) Items Subject to Agreement Between the Assembly Manufacturer and the User
Bibliography
Figure 101 Impact Test Using Striking Element
Table 101 Values of Assumed Loading
Table D.1 List of Design Verifications to be Performed
Table AA.1 List of Notes Concerning Certain Countries
Table CC.1 Items Subject to Agreement Between the Assembly Manufacturer and the User

Page: 1 / 0