GB/T 9489-2024 in English
VALIDMethods for chemical analysis of alundum powder
- Issued on:2024-11-28
- Implemented on:2025-06-01
- File Format:PDF
- Delivery:Within 1 day
$338.00
| Standard No: | GB/T 9489-2024 |
| Document status: | VALID |
| Title in English: | Methods for chemical analysis of alundum powder |
| Title in Chinese: | 刚玉粉化学分析方法 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Within 1 day |
| Issued on: | 2024-11-28 |
| Implemented on: | 2025-06-01 |
| Superseding: |
GB/T 9489-2008 Chemical analysis methods of alundum powder
|
| ICS Classification: | 91.100.10-Cement. Gypsum. Lime. Mortar |
| Chinese Classification: | Q62-Gypsum product |
| Professional Classification: | GB-National Standard |
| Related Keywords: | alundum powder introduction analysis
icp-oes analysis atomic absorption method atomic absorption chemical analysis atomic absorption method |
| Related Topics: | Powder composition analysis method
cod chemical analysis method Corundum Synthesis Method |
《GB/T 9489-2024刚玉粉化学分析方法》由TC406(全国非金属矿产品及制品标准化技术委员会)归口,主管部门为中国建筑材料联合会。
Introduction
Analysis of the core content of the standard
| Test items | Method principle | Instruments and equipment | Measurement range |
|---|---|---|---|
| Multi-element determination | ICP-OES method | Inductively coupled plasma optical emission spectrometer | 0.0065%-2.0% |
| Metal oxides | Atomic absorption method | Atomic absorption spectrophotometer | 0.01%-1.0% |
| Aluminum oxide | Complexometric titration | Analytical balance | ≥90% |
Key technology updates
Main revisions to the 2024 version of the standard:
- New Safety warning clause to clarify experimental safety responsibilities
- Optimize the preparation parameters of silica standard solution (the volumetric flask is adjusted from 200mL to 1000mL)
- Correct the flame type of Ca/Mg elements in the atomic absorption method to air-acetylene flame
- Improve the order of adding flux (borax-sodium carbonate mixed flux)
Typical application cases
Case 1: A company used ICP-OES to determine the Fe2O3 content in corundum powder. By adding matrix-matched Al2O3 solution (10 mg/mL), the matrix interference was effectively eliminated, and the RSD was <1.5%.
Case 2: The laboratory compared the new and old standards to determine TiO2. The linear range of the new working curve was extended to 0.005%-5.0%, and the detection limit was reduced by 40%.
Implementation recommendations
- Sample pretreatment needs to be strictly controlled at 205-215℃ for sealed digestion for 8-10 hours
- For ICP-OES analysis, it is recommended to use the axial observation mode to improve sensitivity
- The boiling time of potassium fluoride substitution reaction in complexometric titration needs to be controlled to 2-3 minutes
- Regularly verify instrument performance, and it is recommended to calibrate with GBW standard materials every month

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 9776-2022 in English
Calcined gypsum
2022-12-30 -

GB/T 5483-2024 in English
Natural gypsum
2024-11-28 -

GB/T 37785-2019 in English
Flue gas desulfurization gypsum
2019-08-30