HG 2823-1997 in English
VALIDTrichlorofluoromethane packing steel drum
- Issued on:1997-01-15
- Implemented on:1997-05-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$127.00
本标准规定了包装钢桶的要求、抽样、试验方法、标志、包装、运输和贮存等。
本标准适用于包装CFC-11、容积为200L的包装钢桶的制造、流通、使用和监督检验等领域,该产品适用于CFC-11的一次性包装。
Introduction
Analysis of the core content of the standard
| Technical dimensions | HG 2823 requirements | GB 325 benchmark | Differences |
|---|---|---|---|
| Structural design | Triple round curling + reinforcement ring | Double curling | Sealing level increased by 30% |
| Airtightness test | 80kPa (type inspection) | 50kPa | Pressure resistance index increased by 60% |
| Coating thickness | ≥0.020mm | No clear requirements | New special requirements for anti-corrosion |
Details of key technical requirements
4.1 Structural specifications
Steel drums must be made of whole steel plates, and the barrel body welding is limited to the use of resistance welding technology. Structural requirements:
- Two external convex ring ribs or 5-7 corrugations for reinforcement
- 19±1mm reinforcement rings are set on the top/bottom of the barrel
- The distance between the spiral injection port and the air vent is 1415±4mm
4.2 Performance indicators
Typical application case: A chemical plant used steel barrels of this standard to contain CFC-11. After a 1.8m drop test, there was no leakage in the barrel and the deformation of the ring ribs was <3%, which fully met the safe transportation requirements for ozone-depleting substances.
Key points for the implementation of the standard
Quality control system
Establish a three-level unqualified classification mechanism according to GB 2828:
- Class A defects: directly affect the sealing (such as weld quality)
- Class B defects: dimensional deviation (ring rib height deviation> 2mm)
- Class C defects: appearance defects (coating sagging)
Inspection process optimization
Suggestions for manufacturers:
- The first piece of each shift must be inspected for air tightness (50kPa)
- Sampling 3 pieces per month for 80kPa enhanced inspection
- Use a magnetic thickness gauge to monitor coating quality
Technology Evolution Analysis
Based on GB 325, this standard mainly strengthens:
- Improving the sealing level in view of the high volatility of CFC-11
- Increasing the requirement for single-use in consideration of the environmental sensitivity of ozone depleting substances
- Introducing polyvinyl chloride lining anti-corrosion technology

Loading PDF document...