Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
stationary sources cems stationary sources continuous emissions monitoring stationary source operation stationary sources annex b die casting aluminum alloys appendix c characteristics 0500-2022 detection method spectrophotometry liquid committee
HJ/T 75-2007 in English

HJ/T 75-2007 in English

SUPERSEDED

Specifications for continuous emissions monitoring of flue gas emitted from stationary sources (on trial)

  • Issued on:2007-07-12
  • Implemented on:2007-08-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $260.00
$253.00
Standard No: HJ/T 75-2007
Document status: SUPERSEDED
Superseded by: HJ 75-2017 Specifications for continuous emissions monitoring of SO2, NOx, and particulate matter in the flue gas emitted from stationary sources
Superseded on: 2018-03-01
Title in English: Specifications for continuous emissions monitoring of flue gas emitted from stationary sources (on trial)
Title in Chinese: 固定污染源烟气排放连续监测技术规范(试行)
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2007-07-12
Implemented on: 2007-08-01
Superseding: HJ/T 75-2001 Technical norm for continuous emissions monitoring of flue gas emitted from thermal power plants
ICS Classification: 13.040.01-Air quality in general
Chinese Classification: Z05-Specifications for pollution control
Professional Classification: HJ-Environment
Related Keywords: stationary sources cems
stationary sources
continuous emissions monitoring
stationary source operation
stationary sources annex b
Related Topics: pollution source
smoke
Stationary pollution source
continuous monitoring
hj t354 2007
pm2.5 fixed pollution source
hj/t299-2007
hj/t 42
hj/t75
hj/t 36
hj/t 397
hj/t 40
hj+t+
Thallium, a stationary source of pollution
hj/t+
hj/t358-2007
hj/ t 55
hj/t 223
hj/t 305
hj/t371-2007
hj/t400-2007
hj/t 279
hj/t 267
hj/t+393-2007
hj/t 270
Continuous Monitoring Technology of Flue Gas Emission from Stationary Pollution Sources
hj/t 398
hj+t
HJ/T+397-2007
hj/t+372-2007
Technical requirements and detection methods of continuous monitoring system for flue gas emission from fixed pollution sources
hj/t354-2007
hj/t367-2007
hj t 327
HJ/T393-2007)
hj/ t 365
hj/t 66
hj/t 315
hj/t75-2007
hj/t 339-2007
hj t 40
hj/t 183
hj/t+355-2007
hj/t 289
smoke emission
Determination of Sulfur Dioxide in Exhaust Gas from Stationary Pollution Sources by Iodometric Method
Pollution source flue gas
Technical requirements and monitoring methods for continuous flue gas monitoring
Fixed pollution source pm2.5
hj/t75+
hj/t377-2007
hj/t and hj
Thallium in flue gas from stationary sources
hj/t353--2007
Technical Guidelines for Pollutant Discharge Monitoring
hj/t 277
hj2007-75
Calibration of Continuous Monitoring System for Flue Gas Emissions from Stationary Pollution Sources
hj/t+366-2007
Flue gas emission monitoring system testing
hj t 354-2007
hj/t373--2007
hj t 42
hj/t356-2007
hj/t 343 2007
Stationary pollution source detection method
Determination of pm2.5 from stationary pollution sources
hj/t404-2007
Monitoring of pollution sources at home and abroad
hj/t 33
hj/t 34
hj75
hj/t 282
hj /t 66
Pollution source detection method
hj and hj/t
Stationary pollution source naphthalene
hj/t 240
hj/t 367
hj/t 273
smoke pollution source
hj/t 378
hj/t300-2007
hj/t 309
hj and hj/t
National sewage discharge regulations
hj/t 46
hj-75
hj /t 40
hj/t393-2007
Stationary source emissions
Thallium, a stationary source of pollution
Technical requirements and detection methods for continuous monitoring system of flue gas emitted by fixed pollution sources
hj t75 2007
hj+t75+2007
hj/t 75
Monitoring method for ultra-low emission of flue gas
Stationary pollution source triphenyl
Stationary pollution source detection
Flue gas emission detection technology
Stationary pollution source flue gas emission
trial run
Smoke emission monitoring
smoke emission
Test release
hj/t 412
Sewage discharge test
Smoke pollution source monitoring
Total amount of stationary pollution sources
Continuous monitoring of flue gas
Continuous Flue Gas Monitoring
hj t75 2001
hj/t75-2001
hj t 354 2007
Smoke emission detection
continuous smoke emission
Continuous smoke emission monitoring
HJ75 2007
hj+t75
hj75-2007
t75 2007
Emissions from pollution sources
Pollution source flue gas
Self-monitoring of flue gas
smoke emission continuous
HJ75+2007
hj t 36
HJ T 373 2007
HJ T397 2007
t75+2007
Dongfang smoke emission continuous monitoring
HJ T353 2007
HJ+T397+2007
Smoke 75
HJ T 397
HJ+T353+2007
hj/t397-2007
Pollutant Discharge Automatic Monitoring Technology
HJ+T400+2007
hj+t354+2007
HJ T 363 2007
HJ T377 2007
Stationary pollution source pollution source exhaust
HJ+T+363+2007
HJ+T+373+2007
smoke in english
hj/t300-2007
Stationary Pollution Source Monitoring Technology
hj/75-2007
hj/t353-2007
hj/t375-2007
hj/t75-2007
hj/t347-2007
24 kinds of fixed pollution sources
Technical Requirements and Monitoring Methods for Continuous Monitoring System of Flue Gas from Stationary Pollution Sources
hj/75
hj/t373-2007
hj/t412-2007
t75-2007
hj75-
hj t 75
hj/t299-2007
Test release
Emissions from stationary sources by country
hj/t 52
Monitoring of Stationary Pollution Source h2
hj/t and hj
Technical requirements and testing methods for continuous monitoring system of flue gas emission from fixed pollution sources
hj/t347-2007
hj/t399-2007
hj and hj/t
hj 75
hj 75-2007
hj/t391-2007
hj/t 358
Continuous Monitoring System of Pollution Sources
Discharge of Class I Pollutants, Regulation
Fixed source phenols
HJ/T342-2007
HJ/T398-2007
HJ/t418-2007
VOCs emissions from stationary pollution sources in key industries
Pollution source automatic monitoring equipment comparison monitoring technical regulations 2020
Calibration Specification for Continuous Monitoring System of Flue Gas Emissions from Stationary Pollution Sources JJF1585-2016
scs-900c type flue gas continuous monitoring
Fixed pollution source flue gas so2nox latest
Monitoring methods for ammonia from fixed pollution sources
Operation and maintenance quality control technology of continuous monitoring system for flue gas emissions from fixed pollution sources
Determination of ethanol in exhaust gas from stationary pollution sources
Technical Specifications for Monitoring Drugs in Sewage (Trial)
Welding fume emission enforcement
Welding fume pollutant emissions
Monitoring and evaluation of stationary pollution sources
Installation acceptance of flue gas from fixed pollution sources
Online acceptance of flue gas from fixed pollution sources
continuous flow technology
Fixed pollution source acceptance technology
hj/t346-2007
Greenhouse gas continuous automatic monitoring technology
hj/t 365
hj /t 399
hj/t-356-2007
hj/t 415
hj /t 267
hj/t-399-2007
hj t340 2007


1 Application Scope

1.1 This standard specifies main technical indexes, testing items, installation positions, testing method, acceptance method, routine operation management, routine operation quality warranty, data audit and formats of data report of CEMS for particular matters, CEMS for gaseous pollutants (including SO2 and NOx) and Continuous Monitoring Systems (CMS) for related emission parameters (such as oxygen content) in Continuous Emissions Monitoring Systems (CEMS) of flue gas emitted from stationary sources.

1.2 This standard is applicable to CEMS of stationary sources such as thermal power plant boilers, industrial/civil boilers and industrial furnaces and kilns with solid and liquid as fuel or raw material.

1.3 This standard may serve as a reference for CEMS of domestic waste incinerators, hazardous waste incinerators, and stationary sources with gas as fuel or raw materials.

2 Normative References

The following normative document contain provisions which, through reference in this text, constitute provisions of this standard. For undated references, the latest edition of the normative document referred to applies.

GB/T 16157 The Determination of Particulates and Sampling Methods of Gaseous Pollutants Emitted from Exhaust Gas of Stationary Source
GB 3095 Ambient Air Quality Standard
HJ/T 193 Automated Method for Ambient Air Quality Monitoring
HJ/T 212 Standard for Data Communication of Pollution Emission Auto Monitoring System
HJ/T 42 Stationary Source Emission—Determination of Nitrogen Oxide— Ultraviolet Spectrophotometric Method
HJ/T 43 Stationary Source Emission—Determination of Nitrogen Oxid—N(1-naphtye)—Ethylenediamine Dihydrochloride Spectrophotometric Method
HJ/T 47 Technical Conditions of Sampler for Stack Gas
HJ/T 48 Technical Conditions of Sampler for Stack Dust
HJ/T 56 Determination of Sulphur Dioxide from Exhausted Gas of Stationary Source - Iodine titration Method
HJ/T 57 Determination of Sulphur Dioxide from Exhausted Gas of Stationary Source— Fixed-potential Electrolysis Method


3 Terms and Definitions

3.1
Continuous Emission Monitoring
continuous and real-time tracking and measurement of pollutants emitted from stationary sources; the total measurement hours of each stationary source shall not be less than 75% of the total operating hours of boilers and kiln; the measurement time per hour shall not be less than 45min.

3.2
Normal Operation of CEMS of Stationary Source
operation within the specified validity period and in compliance with technical index requirements given in this standard, excluding, however, the operation in the case of detector contamination, instrument failure, system calibration and verification or system’s failure to regular calibration or verification.

Foreword i
1 Application Scope
2 Normative References
3 Terms and Definitions
4 Composition of CEMS of Stationary Source
5 Technical Performance Requirements for Stationary Sources CEMS
6 Installation Location Requirements for Stationary Sources CEMS
7 Technology Acceptance of Stationary Sources CEMS
8. Daily Operation and Management Requirements of CEMS for Stationary Sources
9. Daily Operation Quality Assurance of CEMS for Stationary Sources
10 Data Audit and Processing of CEMS for Stationary Sources
11 Data Recording and Statement
Annex A (Normative) Debug Testing Method for Main Technical Indexes of CEMS for Stationary Sources
Annex B (Normative) Testing Result Analysis and Treatment Method for CEMS Technical Index
Annex C (Normative) Data Calculation and Processing
Annex D (Normative) Attached Tables

Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.