Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
modal test analysis vibration measurement methods modal test vibration measurement measurement methods machine rooms engine series upholstered furniture manual operation
JB/T 10392-2002 in English

JB/T 10392-2002 in English

SUPERSEDED

Modal test analysis and vibration measurement methods on the stator core & frame for turbo-generators

  • Issued on:2002-12-27
  • Implemented on:2003-04-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $300.00
$291.00


1 Scope

This standard specifies the modal test analysis and vibration measurement methods and evaluation criteria with regards to stator core and frame for large dipolar turbo-generators.
This standard is applicable to the turbo-generator set with the rated power of 50MW or above.
This standard is applicable to the modal test analysis and vibration measurement and evaluation on the stator core and frame for turbo-generators which are subjected to type test in the manufacturer.
This standard is applicable to the measurement and evaluation on stator core and frame for turbo-generators operating under rated conditions.

2 Normative References

The following normative documents contain provisions which, through reference in this standard, constitute provisions of this standard. For dated reference, subsequent amendments (excluding correction to), or revisions of, any of these publications do not apply. However, parties to coming to an agreement according to this standard are encouraged to study whether the latest edition of these documents applies. For undated references, the latest editions of the normative documents are applicable to this standard.

Foreword I
1 Scope 1
2 Normative References 1
3 Terms and Definitions 2
4 Measurement Methods 2
4.1 Modal Test Analysis 2
4.2 Vibration Measurement 4
5 Measuring Apparatus 5
5.1 Impact Hammer 5
5.2 Vibration Pickup 6
5.3 Amplifier 6
5.4 Analyzer 6
6 Evaluation Criteria 6
6.1 Evaluation Criterion on Modal Test for Stator Core and Frame of Turbo-generator 6
6.2 Evaluation Criterion on Vibration Amplitude 7

Sample only — not a preview of JB/T 10392-2002