JB/T 14809-2024 in English
VALIDElectric intensive storage
- Issued on:2024-03-29
- Implemented on:2024-10-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$262.00
| Standard No: | JB/T 14809-2024 |
| Document status: | VALID |
| Title in English: | Electric intensive storage |
| Title in Chinese: | 电动密集库 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 1~3 business days |
| Issued on: | 2024-03-29 |
| Implemented on: | 2024-10-01 |
| ICS Classification: | 53.080-Storage equipment |
| Chinese Classification: | J83-Storage equipment and handling machinery |
| Professional Classification: | JB-Machinery |
| Related Keywords: | intensive storage introduction standard framework
first electric intensive warehouse mobile storage equipment standard system load test load test case |
Introduction
Standard Framework and Technology Evolution
As my country's first electric intensive warehouse special standard, JB/T 14809-XXXX fills the gap in the mobile storage equipment standard system. The standard integrates modern logistics technologies such as track guidance system and intelligent detection device, and adds 12 innovative indicators such as dynamic stability and regional detection compared to traditional shelf standards.
Definition of core terms
| Terms | Definition | Technical characteristics |
|---|---|---|
| Mobile row | Movable rack running on track | Including drive system, track cleaning device |
| Falling object detection | Ground obstacle recognition | Detection height ≤100mm |
| Pitch | Center distance between adjacent tracks | Typical value 2270mm |
Key technical requirements
6.1 Environmental adaptability
The operating temperature range is -5℃~40℃, the humidity is ≤95%, and the power supply voltage is allowed to fluctuate by ±10%. In special environments, an anti-condensation device needs to be added.
6.2 Safety spacing design
- Distance between moving columns and walls: 50-180mm or >500mm
- Distance between top and ceiling: ≥200mm
- Difference in height between track connections: ≤0.15mm
Performance test system
7.6 Load test case
A car parts warehouse uses a 20-ton moving column for testing:
- Static load test: 25 tons load for 24 hours, deformation <2mm
- Dynamic load test: 25 tons back and forth 20 times, gear train temperature rise ≤15℃
7.8 Noise control
When the test distance is 1m, the background noise effect needs to be deducted (see Table 1), and the actual noise value should be ≤80dB(A). It is recommended to use low-noise reduction motors and rubber wheel rims.
Implementation suggestions
Main points for installation and commissioning
- Track levelness control: ≤1mm within 1000mm
- Ground resistance test: needs to be <4Ω (it is recommended to use an independent grounding electrode)
- Safety interlock verification: single/online mode switching test
Operation and maintenance management
Establish a load distribution record table to avoid the adverse loading conditions described in Article 6.9. Recommended monthly inspections:
- Wear status of track cleaning device
- Compression performance of buffer
- Response time of emergency stop button (should be <0.5s)