Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
standard colored stone metal tiles colored stone colored stone particles stone key technical indicators performance category international standard requirements field plot introduction technical background key parameters indicators citrus fruit fly/guava fruit specific energy consumption requirements
JC/T 2470-2018 in English

JC/T 2470-2018 in English

VALID

Stone coated cetal roofing tile

  • Issued on:2018-04-30
  • Implemented on:2018-09-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $150.00
$146.00
Standard No: JC/T 2470-2018
Document status: VALID
Title in English: Stone coated cetal roofing tile
Title in Chinese: 彩石金属瓦
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2018-04-30
Implemented on: 2018-09-01
Professional Classification: JC-Building Material
Related Keywords: standard colored stone metal tiles
colored stone
colored stone particles
stone
key technical indicators performance category international standard requirements
Related Topics: jc/t2441-2018
Metals and Metal Ore
Color stone metal tile
Color steel tile repair
Colored Stone Metal Tile Execution
metal tiles
Metal tile industry
jc/t2458-2018
jc/t 2436-2018
jc/t-2456-2018
jc/t950-2018

本标准规定了彩石金属瓦的术语和定义、分类和标记、一般要求、技术要求、试验方法、检验规则、包装、标志、运输和贮存。
本标准适用于工业和民用建筑屋面的彩石金属瓦。


Introduction

Interpretation of the core content of the standard

Colored stone metal tiles are a new type of roofing material that uses hot-dip aluminum-zinc steel plates as substrates and is compounded with colored stone particles through environmentally friendly adhesives. This standard systematically regulates its technical requirements, test methods and acceptance rules for the first time.


Comparison of key technical indicators

Performance category International standard requirements JC/T 2470 indicators Technical differences
Weather resistance ASTM D4798 500h 1000h artificial aging Weather resistance cycle increased by 100%
Load bearing performance EN 494 800N/m² 1200N/420mm Load capacity increased by 50%
Fire rating UL790 Class A GB8624 B1 Equivalent to international Class A standard

Key quality control points

Raw material requirements

  • Substrate thickness ≥0.4mm, coating ≥80g/m² (measured allowable deviation ±0.02mm)
  • Basalt-based sintered materials are preferred for colored stone particles, and quartz sand is prohibited
  • The VOC content of the adhesive must comply with GB 18583

Key points of process control

  1. The coverage of colored stone must reach 100%, and the deviation of particle distribution uniformity must be ≤5%
  2. The composite pressure must be controlled in the range of 0.5-0.8MPa
  3. Curing temperature maintained at 120±5℃ for 30 minutes

Details of the test method

Weathering test

According to GB/T 16259, 1000h accelerated aging is carried out. Special attention should be paid to the following:

  • Irradiance is controlled at 500-600W/m²
  • Black standard temperature is 65±3℃
  • Water spraying cycle is 18min/102min

Key parameters of load-bearing test

Loading rate 1mm/min
Span 300mm
Press roller size 252×25mm

Standard implementation recommendations

Design application guidance

It is recommended to use main tile (ZW) specifications of 1340×420mm and overlap length ≥75mm when the roof slope is ≥15°; in typhoon-prone areas, products with a base plate thickness of ≥0.45mm should be selected.

Key points for construction acceptance

  1. Every 5,000 sheets are accepted as a batch, and 50 sheets are randomly selected for initial inspection
  2. Focus on checking the sealing of nail holes (water injection test)
  3. Color difference detection should be carried out under D65 standard light source

Technology evolution analysis

Compared with the 2008 version of industry practice, this standard:

  • Added freeze-thaw cycle resistance (20 times) and acid and alkali resistance (48h) indicators
  • Increased the salt spray test time from 500h to 1000h
  • Specified that the combustion performance must reach B1 level

Reflects the industry's development towards long-term durability, safety and environmental protection.

Sample only — not a preview of JC/T 2470-2018