Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
laboratory space design standard unit combination design modular design scientific research buildings introduction analysis standard chaptercore acute immobilisation test non-alcohol beer training objects
JGJ 91-2019 in English

JGJ 91-2019 in English

VALID

Standard for design of scientific research buildings

  • Issued on:2019-07-30
  • Implemented on:2020-01-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $750.00
$728.00
Standard No: JGJ 91-2019
Document status: VALID
Title in English: Standard for design of scientific research buildings
Title in Chinese: 科研建筑设计标准
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 5 business days
Issued on: 2019-07-30
Implemented on: 2020-01-01
Superseding: JGJ 91-1993 Code for design of scientific experiment buildings
Professional Classification: JG-Building
Related Keywords: laboratory space design
standard unit combination design
modular design
scientific research buildings introduction analysis
standard chaptercore
Related Topics: Concentrate on scientific research
research
Research path
scope of scientific research
Research path
research
Concentrate on scientific research
Concentration + scientific research
R&D power
and scientific research
R&D power
scientific research teaching
scientific research test
Equipment research
architectural design
Equipment research
jgj91
test scientific research
Siwei scientific research
Research Analysis
Teaching and Research
Research use
scientific research
Research plan
Research relationship
Research requirements
construction technology
True scientific research
construction technology
researchers
scientific research view
Research activities
scientific new year
real scientific research
motivation for scientific research
scientific research industry
Research grant
Scientific research
Scientific research breaks five
Research system
Second-hand scientific research equipment
Scientific research power film
Research Peptides
Scientific reason
Research measurement
Research Peptides
Research measurement
Scientific Research Area 2
Scientific research measuring equipment
Research Building Design
Involvement in scientific research
Are there any national standards for scientific research kits?
Summary of R&D standards
Standardization construction of scientific research reagents
European standard architectural design


Introduction

Analysis of the core content of the standard

ChapterCore requirementsKey technical indicators
Laboratory classificationDivided into 7 functional areasNet height of general/special laboratory area ≥2.6m
Safety protectionIndependent storage of dangerous goodsExplosion-proof distance ≥1.5m, negative pressure ventilation
Ventilation systemFume hoods are given prioritySurface wind speed 0.25-0.75m/s

Key technical specifications

1. Laboratory space design

The standard unit combination design must meet the following requirements: span ≥ 2.8m, depth ≥ 6.0m, and the net distance between the central laboratory table and the side table ≥ 1.5m. The fume hood should avoid interference from the main airflow and be ≥ 1.2m away from doors and windows.

2. Safety protection system

  • Dangerous chemical storage rooms must be equipped with 24h mechanical ventilation
  • Areas using radioactive materials must be equipped with a protective shielding layer
  • Emergency facilities: Eyewash station + spray device
  • for every 100㎡

3. Mechanical and electrical system specifications

System typeRequirements
VentilationSupplementary air volume ≥ 90% of exhaust air volume
ElectricalLaboratory grounding resistance ≤ 4Ω
Water supply and drainageCorrosive sewage pipes use PPR material

Implementation suggestions

  1. Preferably adopt modular design to reserve space for renovation
  2. Establish a three-level protection system: engineering control-management measures-personal protection
  3. Special laboratories require BIM pipeline integration pre-arrangement

Sample only — not a preview of JGJ 91-2019
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend