JG/T 210-2018 in English
VALIDPrimer for interior and exterior wall
- Issued on:2018-11-07
- Implemented on:2019-04-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
Price(USD):
$260.00
$253.00
$253.00
| Standard No: | JG/T 210-2018 |
| Document status: | VALID |
| Title in English: | Primer for interior and exterior wall |
| Title in Chinese: | 建筑内外墙用底漆 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 1~3 business days |
| Issued on: | 2018-11-07 |
| Implemented on: | 2019-04-01 |
| Superseding: |
JG/T 210-2007 Primer for interior and exterior wall
|
| ICS Classification: | 87.040-Paints and varnishes |
| Chinese Classification: | G51-Coating |
| Professional Classification: | JG-Building |
| Related Keywords: | film-forming primer
external wall type primer indoor humid environment primer wdq-ci type |
| Related Topics: | exterior wall
end Primer JG/T210-2007 JG/T210-2018 Primer for interior and exterior walls of buildings JG/T210-2018 "Primer for interior and exterior walls of buildings" Liquid inorganic coatings for interior and exterior walls of buildings |
Introduction
Core changes in the standard revision
| Technical elements | 2007 version of the standard | 2018 version of the standard |
|---|---|---|
| Definition of terms | Salting-out resistance | Salting-out resistance (newly added penetration type/film-forming type classification) |
| Technical requirements | Adhesion index | Delete adhesion, add reinforcement performance (≥0.2MPa) |
| Test method | Single alkali resistance test | Compound salt-alkali test (NaOH+CaCO3+CaCl2 solution) |
Analysis of key technical indicators
Physical performance requirements
The standard clearly distinguishes the technical indicators of film-forming primer and penetrating primer:
- Water permeability: External wall type I ≤0.3mL, type II ≤0.5mL
- Anti-salt-alkali performance: Type I has no abnormality for 120h, type II has no abnormality for 72h
- Reinforcement performance: Penetrating type must be ≥0.2MPa
Implementation suggestions
Material selection
Select the type of primer according to the base condition:
- High alkaline base: WDQ-CI type film-forming primer is preferred
- Loose porous base: WDQ-S-II type penetrating primer
- Indoor humid environment: NDQ-S type needs to pass 96h water resistance test
Key points for construction control
Standard 6.4.2 clearly stipulates:
- When the dilution ratio is clearly stated, take the middle value
- Brush coating amount calculation formula: m=ρ×S×80×10-4
- The interval between two constructions is ≥6h
Testing Method Innovation
The new version of the standard makes important improvements in the following testing methods:
| Test Items | Key Improvements |
|---|---|
| Anti-salinity and alkalinity | Use 2%PVA-iron blue indicator, observe the color change area ≤10% |
| Reinforcement performance | 0.5%PVA-CaCO3 substrate method, remove the maximum and minimum values and take the average |
| Water permeability | Special funnel device, allowable error ≤0.2mL |
Sample only — not a preview of JG/T 210-2018

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

JG/T 235-2014 in English
Architectural Reflective Thermal Insulation Coatings
2014-01-07 -

JG/T 304-2011 in English
Anti-graffiti and/or stickresist coatings for buildings
2011-02-17 -

JG/T 434-2014 in English
Wood Wax Oil Finish for Wood Structures
2014-06-12 -

JG/T 349-2011 in English
Silicone modified acrylic permeability waterproof coating
2011-12-07