Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
underground communication conduit introduction core changes color strip silicon core tube high-density polyethylene silicore duct added normative appendix f test procedures key instrument requirements silicon core tube investigation activities additive triglycerol monostearate test mask
JT/T 496-2018 in English

JT/T 496-2018 in English

VALID

High-density polyethylene silicore duct for highway underground communication conduit

  • Issued on:2018-08-29
  • Implemented on:2018-12-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $500.00
$485.00
Standard No: JT/T 496-2018
Document status: VALID
Title in English: High-density polyethylene silicore duct for highway underground communication conduit
Title in Chinese: 公路地下通信管道高密度聚乙烯硅芯塑料管
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2018-08-29
Implemented on: 2018-12-01
Superseding: JT/T 496-2004 High-density polyethylene silicon duct for highway communication conduct
Professional Classification: JT-Transport
Related Keywords: underground communication conduit introduction core changes
color strip silicon core tube
high-density polyethylene silicore duct
added normative appendix f test procedures key instrument requirements
silicon core tube
Related Topics: Underground Line + Company
high density
plastic pipe
Pipe Density Meter
Core core high throughput
High-density polyethylene
jt/t 1180.21-2018
jt/t1187-2018
Low Density and High Density Plastics
JT/T 1180.6-2018
silicon core

本标准规定了公路地下通信管道高密度聚乙烯硅芯塑料管的产品结构、分类与标记、技术要求、试验方法、检验规则,以及标志、包装、运输和储存等要求。
本标准适用于公路地下通信高密度聚乙烯硅芯塑料管的生产、检验和使用,多孔组合高密度聚乙烯塑料管道可参照使用。
本标准不适用于室外直接暴露于太阳光下的通信光、电缆用保护管。


Introduction

Core changes in the standard revision

Revision content 2004 edition 2018 edition Technical significance
Product structure Single tube only Newly added cluster tube (J type) Adapt to the needs of porous combined pipes
Specifications and models 7 types Newly added 12/9, 16/13 micro tubes, a total of 14 types Expanded application scenarios
Friction coefficient No requirement for test bar hardness Clear Shore hardness (59±3) HD Improve test accuracy

Analysis of key technical indicators

Physical and chemical performance requirements

  • Static friction coefficient: ≤0.25 (plate method test)
  • Ring stiffness: ≥40kN/m² (to ensure compressive strength)
  • Environmental stress cracking resistance: 48h failure rate ≤20%
  • Recovery rate: ≥85% after 10 minutes of compression of 50%

Structural feature requirements

The outer tube and micro tube of the cluster tube must meet the independent and non-contact principle, the outer color should comply with the color spectrum requirements of GB/T 6995.2, and the color strip silicon core tube needs to be evenly distributed with 4 groups of color strips with a thickness of 0.1-0.3mm.


Key points for construction and application

Technical requirements for connectors

Air-tight performance No leakage at 0.1MPa pressure for 24h
Connection force ≥4300N (φ40/33 specification)
Chemical corrosion resistance Pass 5%NaCl, 40% acid and alkali solution tests

Storage and transportation specifications

  1. Each reel of silicon core tube should be marked with product mark + production date + reel number
  2. Forklifts/cranes must be used for unloading, and direct pushing is prohibited
  3. The stacking site must be flat, away from heat sources and a no-fire sign must be set up

Comparison of detection methods

Main test changes between the new and old standards

  • Dynamic friction coefficient: Added the drum method (Appendix D) as a process comparison method
  • Out-of-roundness test: Clarified the 5-section measurement method (Appendix B)
  • Resistance to thermal stress cracking: Added normative Appendix F test procedures

Key instrument requirements

The accuracy of the load cell of the universal testing machine must be ≥ Grade 1, the graduation value of the vernier caliper is 0.02mm, and the micrometer with a graduation value of 0.01mm is recommended for wall thickness measurement.