Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
light intensity type light intensity light intensity attenuation effective light intensity formula light intensity calculation introduce key safety requirements software behavior glasses scopethis part
MH/T 6012-2015 in English

MH/T 6012-2015 in English

SUPERSEDED

Aeronautical obstacle light

  • Issued on:2015-12-22
  • Implemented on:2016-01-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $450.00
$437.00
Standard No: MH/T 6012-2015
Document status: SUPERSEDED
Superseded by: MH/T 6012-2015/XG1-2017 Aeronautical obstacle light, includes Amendment 1
Superseded on: 2017-05-25
Title in English: Aeronautical obstacle light
Title in Chinese: 航空障碍灯
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2015-12-22
Implemented on: 2016-01-01
Superseding: MH/T 6012-1999 Aeronautical obstacle light
Professional Classification: MH-Civil Aviation
Related Keywords: light intensity type
light intensity
light intensity attenuation
effective light intensity formula
light intensity calculation introduce
Related Topics: mh/t 6012-2015
mh/t5111-2015
mh/t+6012-2015
mh/t 0054.1 2015
barrier
mh/t5110-2015
mh/t 0054.1-2015
obstacle
sail
multiple obstacles
pool barrier
mh/t 2015
/barrier
ios accessibility
MH/T6102-2015
mh6012
mh/t6012- 2015
mh6012-2015


Introduction

Background and evolution of standard revision

MH/T 6012-2015 replaces the 1999 version of the standard. The main technical upgrades include:

Revision dimensions 1999 version 2015 version
Lamp classification 3 categories Expanded to 8 categories (newly added A/C/D low-intensity, C-type medium-intensity)
Technical parameters Basic light intensity requirements Added effective light intensity calculation formula and chromaticity coordinate specifications
Environmental adaptability -40℃~55℃ Added 6 harsh environment tests such as salt spray and radiation

Core classification system

Obstruction lights are divided into three categories and nine types according to light intensity. Key parameters are compared:

Type Representative model Light intensity range (cd) Flash frequency
Low light intensity Type B 32 (constant) -
Medium light intensity Type A 20,000~100,000 20-60 times/min
High light intensity Type B 200,000+ 40-60 times/min

Key technical requirements

5.2.5 Chromaticity specification

Strictly limited by CIE chromaticity coordinates:

  • Red: x≥0.980-7y and y≤0.335
  • White: x≤0.440 and y≥0.150+0.640x

5.3.1 Light Intensity Calculation

Introduce the effective light intensity formula:
Ieff = ∫I(t)dt / (0.2+t2-t1)
Where t1, t2 are the start and end times of the flash


Implementation Recommendations

Selection Guide

  1. Building height <45 meters: Use Type B low-intensity obstacle lights
  2. 45-150 meters: Use a combination of medium-intensity and low-intensity lamps
  3. >150 meters: Type A high-intensity obstacle light system must be configured

Maintenance points

According to standard 5.2.16 requirements:
LED light source life must be ≥50,000 hours
Annually, the following tests should be performed:
1) Light intensity attenuation test
2) Chromaticity shift test
3) Control device function verification

Sample only — not a preview of MH/T 6012-2015