Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
solid-state power introduction analysis static power supply verification points compound efficiency test aircraft ground standard revision revision items specific thermal resistance ≤3.5×10-6/℃ gb/t4339 tensile strength ≥1030mpa gb/t228.1 phase transition temperature actinidia chinensis cultivars
MH/T 6018-2014 in English

MH/T 6018-2014 in English

VALID

Aircraft ground solid-state power

  • Issued on:2014-08-25
  • Implemented on:2014-12-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $630.00
$612.00


Introduction

Analysis of the key points of standard revision

Revision items 1999 edition 2014 edition
Voltage standard DC 28.5V Unified to DC 28V
Operating temperature -20℃~50℃ Outdoor type -30℃~55℃, indoor type 0℃~40℃
Efficiency requirement 85% Compound efficiency≥90%

Key technical requirements

1. Electrical characteristics indicators

AC static power supply must meet the following requirements:

  • Three-phase voltage unbalance ≤4.0V (3V for the 1999 version)
  • Total harmonic distortion coefficient ≤5%
  • Sudden load capacity reaches 150% of rated capacity

DC static power supply Newly added:

  • Maximum current under engine starting condition2200A
  • The distortion spectrum must comply with the limit values in Figure 9

2. Electromagnetic compatibility upgrade

The input side must meet the following requirements at the same time

  1. IEC 61000-6-2:2005 Industrial environment immunity
  2. GB 17799.4-2012 Emission requirements

Implementation suggestions

Precautions in the design phase

according to Appendix A.
Key points Solution
NBPT function implementation Using ±2Hz frequency synchronization technology, parallel switching time ≤100ms
Highland application When the altitude is >1000m, perform derating design

Test and verification points

  • Compound efficiency test requires weighted calculation at 25%/50%/80%/100% load points
  • Transient characteristics test requires the use of 1.25MHz sampling rate equipment (Appendix B)
  • Protection level verification requires an IP54 rain test (Article 5.28)

Sample only — not a preview of MH/T 6018-2014