Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
lightning protection system ancient trees ancient trees age lijiang ancient town protection project national lightning disaster prevention industry standardization technical committee time base error characteristics coal gangue power plants critical flow meter
QX/T 231-2014 in English

QX/T 231-2014 in English

VALID

Technical speciticaHon for lightning protection of ancient and rare trees

  • Issued on:2014-07-25
  • Implemented on:2014-12-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $230.00
$224.00
Standard No: QX/T 231-2014
Document status: VALID
Title in English: Technical speciticaHon for lightning protection of ancient and rare trees
Title in Chinese: 古树名木防雷技术规范
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2014-07-25
Implemented on: 2014-12-01
ICS Classification: 07.060-Geology. Meteorology. Hydrology
Chinese Classification: A47-Meteorology
Professional Classification: QX-Meteorology
Related Keywords: lightning protection system
ancient trees
ancient trees age
lijiang ancient town protection project
national lightning disaster prevention industry standardization technical committee
Related Topics: tree elasticity
QX
Ancient and famous trees
Lightning protection engineering technology for ancient buildings


Introduction

Standard Background and Significance

This standard was proposed by the National Lightning Disaster Prevention Industry Standardization Technical Committee and formulated for the special protection object of ancient and famous trees. With the advancement of ecological civilization construction, the protection needs of ancient trees over 100 years old and famous trees with historical and cultural values are becoming increasingly prominent. Statistics show that lightning strikes have become the second largest natural factor leading to the death of ancient trees.


Definition of core terms

TermsDefinitionKey technical points
Ancient trees Age ≥ 100 years The impact of annual ring growth on the fixing device needs to be considered
Lightning protection system (LPS) Lightning terminal + down conductor + grounding device Impact grounding resistance ≤ 30Ω
Lightning terminal Lightning terminal rod/belt/wire/net Above the tree canopy ≥ 1.0m

Key technical requirements

1. Specifications for lightning arrester installation

When using non-metallic clamps for fixing, the following must be met:

  • Width ≥ 40mm and thickness ≥ 4mm
  • Width of lining flexible material > clamp width
  • No less than 3 fixing points

2. Key points for down conductor installation

Yunnan case: In the Lijiang Ancient Town protection project, multi-core copper stranded wires (cross-sectional area ≥ 50mm²) were laid along tree trunks and protected by 100kV insulating sleeves, which effectively solved the safety protection problem in crowded places in tourist areas.

3. Special treatment of grounding device

When the root system is on the soil surface:

  1. Horizontal grounding electrode needs to be insulated
  2. The buried position should be ≥3m away from the tree crown projection
  3. Ring grounding electrode is preferred

Implementation suggestions

Maintenance and management requirements

ProjectPeriodInspection content
Regular inspection Half a year Loose and rusty connections
Inspection after thunderstorm Immediately Traces of lightning damage
Resistance detection Annual inspection Impact grounding resistance value

Special requirements for cultural relics protection

For ancient trees in scenic areas:

  • Insulating sleeves shall be installed for the section below 2.7m of the down conductor
  • Warning signs in Chinese and English shall be set up
  • Guardrail height ≥ 0.8m and non-metallic material shall be used