QX/T 475-2019 in English
VALIDTechnical requirements for air negative ions automatic measurement instrument. Capacitance inhalation
- Issued on:2019-01-26
- Implemented on:2019-05-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$165.00
Introduction
Analysis of the core content of the standard
This standard clearly stipulates the system architecture, technical parameters and detection methods of the capacitive inhalation method air negative ion automatic measuring instrument. Its core technical indicators include:
| Key parameters | Technical requirements | Test conditions |
|---|---|---|
| Ion mobility critical value | 0.4 cm²/(V·s) | Error ≤±10% |
| Negative ion concentration range | 10-5×10⁵/cm³ | Resolution 10/cm³ |
| Measurement error | ±15% | 100-5×10⁴/cm³ |
| Sampling frequency | ≥6 times/minute | Single interval 5 minutes |
Detailed explanation of key technical requirements
4.1 System modular design
The standard requires that the instrument must adopt a modular architecture of plate collector, collector and peripheral devices:
- Plate collector: Contains parallel metal plates and fans, polarization voltage ≥16V
- Collector: Must be equipped with 16-bit A/D conversion circuit, data storage ≥10 days
- Environmental adaptability: Working temperature -30℃~50℃, humidity 10%~100%RH
5.2 Performance indicator matrix
Instrument stability requirements in extreme environments:
- Requires normal operation in high humidity environments (≥85%RH)
- Plate short-circuit protection response time <1 second
- MTBF >2500 hours
Implementation and application recommendations
Key points for equipment selection
According to the QX/T 419-2018 observation specification, it is recommended to give priority to:
- Equipment with dual power supply modes (AC220V/DC24V)
- Configure lightning protection and grounding measures (resistance <4Ω)
- Models with temperature/humidity compensation functions
Maintenance and management specifications
Based on clause 6.6 of the standard, it is recommended that:
- Consistency testing of three instruments is performed quarterly
- Check plate cleanliness monthly
- Ion mobility parameters are calibrated annually
Technology Evolution Analysis
Main improvements compared to earlier versions:
- Measurement accuracy: A/D conversion improved from 12 bits to 16 bits
- Environmental adaptability: Operating temperature range extended by 10°C
- Intelligence: New wireless communication and fault self-diagnosis functions

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

QX/T 705-2023 in English
Technical Specifications for Division of Lightning-prone Areas
2023-12-30 -

QX/T 214-2025 in English
Greenhouse Gas Sampling Methods for Stainless Steel Tanks
2025-05-19 -

QX/T 317-2023 in English
General rules for quality assessment of lightning protection device testing
2023-09-05 -

QX/T 750-2025 in English
Technical Requirements for Automatic Weighing System of Atmospheric Aerosol Filter Membranes
2025-03-07 -

QX/T 712-2024 in English
Climate Change Impact Assessment Food Crop Yield Vulnerability
2024-06-20 -

QX 30-2005 in English
Technical specifications for lightning protection in automatic weather stations
2005-02-04