本标准规定了雷电防护装置检测作业安全的基本要求,以及高处危险场所、爆炸和火灾危险场所、配电室、数据中心机房、建筑施工现场的雷电防护装置检测作业安全要求。
本标准适用于高处危险场所、爆炸和火灾危险场所、配电室、数据中心机房、建筑施工现场雷电防护装置检测的作业安全。
Introduction
Interpretation of the core content of the standard
QX/T560-2020 is the first safety standard in my country's meteorological industry specifically for lightning protection device inspection operations. It systematically constructs a complete safety system including equipment operation such as ground resistance tester, personnel protection, and special site inspection.
Comparison of key safety control dimensions
| Operation type | Core risk | Protective measures | Instrument requirements |
|---|---|---|---|
| Dangerous places at heights | Falling, object impact | Double-hook safety belts, non-slip shoes, time-limited operation | Portable equipment ≤5kg |
| Explosion-hazardous places | Static sparks, gas explosion | Anti-static clothing, gas detection first | Explosion-proof instruments |
| Distribution room detection | Electric shock, arc injury | Insulation tools, electrical testing procedures | CAT III instruments |
Technology evolution and standard innovation
This standard takes into account the operational safety requirements of UAV detection technology for the first time, and adds clauses such as anti-interference of remote control equipment and flight restricted area setting for new detection methods. Compared with the basic standard GB/T21431-2015, special specifications for electromagnetic compatibility testing of data center computer rooms have been added.
Typical application cases
During the inspection of the storage tank area of a petrochemical enterprise, the inspection team strictly implemented the terms of Appendix C.2.1 and used the underground pipeline detector to confirm that the grounding electrode position was away from the oil pipeline to avoid safety accidents caused by piling operations.
Implementation suggestions
- Establish a three-level confirmation system before testing operations: site risk assessment → protective equipment inspection → emergency plan notification
- In high temperature environments, implement segmented testing according to the requirements of Appendix D, and rotate operators every 45 minutes
- For special building (structure) inspections, climbing path video records should be kept for reference
Key points for standard implementation
Focus on Article 5.2 Prohibited behaviors for high-altitude operations: high-risk operations such as climbing using scaffolding poles and moving crane booms. According to Appendix F, the use of ladders must meet the 75° inclination rule, that is, horizontal distance = 1/4 ladder height.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

QX/T 705-2023 in English
Technical Specifications for Division of Lightning-prone Areas
2023-12-30 -

QX/T 712-2024 in English
Climate Change Impact Assessment Food Crop Yield Vulnerability
2024-06-20 -

QX/T 750-2025 in English
Technical Requirements for Automatic Weighing System of Atmospheric Aerosol Filter Membranes
2025-03-07 -

QX/T 41-2022 in English
air quality forecast
2022-01-07 -

QX/T 63-2007 in English
Specifications for surface meteorological observation. Part19: Monthly meteorological radiation data
2007-06-22 -

QX/T 740-2024 in English
Generating specifications for urban forecasts based on grid forecasts Weather phenomena
2024-11-26