Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
x-ray fluorescence spectrum method determination method lubricating oil x-ray fluorescence intensity mathematical method aryloxyphenoxypropionate herbicide residues lubrication greases emergency logistics information standard system
SH/T 0631-1996 in English

SH/T 0631-1996 in English

VALID

Determination method for barium, calcium, phosphorus, sulfur and zinc in lubricating oil and additive (X-ray fluorescence spectrum method)

  • Issued on:1996-05-24
  • Implemented on:1996-12-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $220.00
$214.00
Standard No: SH/T 0631-1996
Document status: VALID
Title in English: Determination method for barium, calcium, phosphorus, sulfur and zinc in lubricating oil and additive (X-ray fluorescence spectrum method)
Title in Chinese: 润滑油和添加剂中钡、钙、磷、硫和锌测定法(X射线荧光光谱法)
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 1996-05-24
Implemented on: 1996-12-01
Professional Classification: SH-Petrochemical
Related Keywords: x-ray fluorescence spectrum method
determination method
lubricating oil
x-ray fluorescence intensity
mathematical method
Related Topics: Fluorescence Spectroscopy
x-ray fluorescence
xFluorescent Reagent
sh t0629 1996
Fluorescence Spectroscopy
x-ray fluorescence standard
sh+t0629+1996
X-ray fluorescence
x-ray fluorescence standard
calcium phosphorus
Disulfiram spectrum
fluorescence spectroscopy
line fluorescence spectroscopy
thiamine fluorescein
x-ray fluorescence spectroscopy
SH/T+0629-1996
SH/T+0629-1996+
X-ray fluorescence spectroscopy
Phosphobarium lubricating oil
Fluorescence Spectroscopy and X-ray Fluorescence Spectroscopy
Determination of Lanthanum and Yttrium in Molybdenum by X-fluorescence Spectrometry
Fluorescence Spectrometry Peaks
x-ray fluorescence spectrometry
spectral heating
x-ray fluorescence spectroscopy
fluorescent and phosphorescent
x-ray fluorescence spectroscopy
sh/t0630-1996
Determination of phosphorus, sulfur, calcium and zinc in lubricating oils by energy dispersive x-ray fluorescence spectrometry
ray fluorescence spectrometry
Lubricant Additives
x-ray spectroscopy
x-ray fluorescence spectroscopy
Multiple peaks in the fluorescence emission spectrum
Phosphorus, sulfur, calcium and zinc content in lubricating oil
Fluorescent determination of oil samples
fluorescence and phosphorescence
Fluorescent Phosphorus
Phosphorescence and Fluorescence
Fluorescence and phosphorescence6
x-ray fluorescence
Spectrometer sample
Phosphorescence and Fluorescence
fluorescent and phosphorescent
fluorescent light
x-ray fluorescence spectroscopy
Fluorescence and phosphorescence somewhat
Ratio of Fluorescence to Phosphorescence
x-ray fluorescence and icp
Spectrometer sample
Phosphorus and sulfur
Fluorescence Spectrum of Gasoline
fluorescence spectroscopy
x-ray fluorescence
X-ray fluorescence
Fluorescence
X-ray Spectroscopy and Energy Spectroscopy
Determination of oil in water Fluorescence
calcium phosphorus
X-fluorescence analysis of element content of lubricating oil additives
Fluorescence and Emission Spectroscopy
Lubricating oil spectrometer
Spectroscopy and Fluorescence
Calcium in lubricating oil
X-ray Spectroscopy and Fluorescence
x-ray fluorescence spectrometry
Fluorescence Spectroscopy
From the fluorescence spectrum
sh t 0356-1996
sh/t 0356-1996
sh/t0356-1996
sh1996
X-ray fluorescence spectroscopy for niobium and sulfur
X-ray fluorescence spectroscopy
lubricating oil x fluorescent
Lubricating oil x fluorescence analysis
SH/T 0631-1996
Applications of X-ray Fluorescence Spectroscopy
Fluorescence spectrum lines are not smooth
X-ray fluorescence filter paper drip method
Advantages of X-ray Fluorescence Spectrometry
X fluorescent release agent
The role of x-ray spectroscopy in drug research
Guangguang


1 Scope

This standard is applicable to determination of contents of barium, calcium, phosphorus, sulfur and zinc in lubricating oil and additive with element concentration scope of 0.03%(m/m)~1.0%(m/m)[0.01%(m/m)~2.0%(m/m) for sulfur]. The lubricating oil and additive with high element concentration may be determined after dilution.

2 Summary of Method

2.1 Calibration of measurement strength of analytic element with mathematical method may prevent from interference of other elements in the specimen and X ray fluorescence spectrum strength of all the elements shall be known in case of calibration with mathematical methods.
2.1.1 Place the specimen in X ray bundle and determine X-ray fluorescence intensity and background intensity of analytical line of barium, calcium, phosphorus, sulfur and zinc; the analytic element concentration is obtained by the measured net strength (analytical line intensity minus background intensity) and the correction factor obtained from the standard sample through calculation.
2.1.2 The inter-element correction factor may be calculated through regression analysis with a series of standard samples and the initial calibration is also carried out for X-ray fluorescence spectrometer.
2.1.3 The apparatus calibration may be finished with a small amount of specimen and only carried out when the inter-element correction factor needs to be re-determined. In case of lots of analysis, any of these specimens may monitor the drifting of the apparatus.
2.2 Specimens may be diluted with a diluent (white oil, coal oil and dimethylbenzene etc) in case of determination of additive or complex additive to make the analytic element concentration within the scope specified in Chapter 1.

3 Significance and Use

Some lubricating oils formulae contain the organometallic additive which plays an roles of detergent agent, oxidation inhibitor and antiwear additive etc. ; some additives contain one or more elements of barium, calcium, phosphorus, sulfur and zinc and this standard provides methods to determine the concentration of the five elements. The measured concentration provides data for the contents of additive in lubricating oil.

Contents
Foreword I
1 Scope
2 Summary of Method
3 Significance and Use
4 Interference
5 Apparatus
6 Reagents and Materials
7 Preparation of the Calibration Standard Sample
8 Calibration
9 Procedure
10 Precision and Bias

Sample only — not a preview of SH/T 0631-1996
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.