Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
fundamental technical requirements technical requirements key technical requirements standard technical dimensioncentrifugal pumpaxial flow sand-containing water flow condition valve-regulated sealed lead-acid battery technology part-turn valve actuator attachments on-orbit space radiation biology experiments
SL/T 806-2020 in English

SL/T 806-2020 in English

VALID

Fundamental technical requirements for pumps of water and hydropower proj ects

  • Issued on:2020-11-30
  • Implemented on:2021-02-28
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $480.00
$466.00


Introduction

Interpretation of the core content of the standard

Technical dimensionCentrifugal pumpAxial flow pump/mixed flow pumpTube flow pump
Impeller clearance requirement≤0.2% impeller diameter≤0.15% impeller diameter≤0.1% impeller diameter
Cavitation reference planeFirst stage impeller outlet centerIntersection of blade axis and outer edge0.5D below the highest point of the blade
Vibration limit (mm/s)4.5 (vertical)/2.8 (horizontal)3.5 (water guide bearing part)

Analysis of key technical requirements

1. Hydraulic performance guarantee: The efficiency of the prototype pump needs to be corrected through model tests, and the correction formula is Δη=(Reproto/Remodel)0.16, where the Reynolds number Re=πDn/ν.

2. Material selection: The sand-containing water flow condition requires a 06Cr13Ni4Mo stainless steel impeller, and the hardness of the flow-through parts must be ≥250HBW.

3. Transition process control: The runaway speed shall not exceed 130% of the rated speed, and the transient pressure fluctuation shall be controlled within ±30% of the design pressure.


Key points for standard implementation

  1. Factory acceptance must include pressure resistance test (1.5 times the working pressure) and 72-hour continuous operation test
  2. When the sand content is greater than 1kg/m³, an additional wear life calculation report shall be provided
  3. Vibration monitoring points shall be arranged at the bearing seat and the inlet and outlet flanges

Standard evolution comparison

Main updates compared to the 2005 version: ①Newly added technical requirements for cross-flow pumps; ②Detailed cavitation margin measurement method; ③Changed vibration evaluation from displacement value to velocity root mean square value.