SN/T 5264-2020 in English
VALIDDetermination of 14 trace oxygenates in naphtha-Deans switch-didimensional capillary gas chromatography method
- Issued on:2020-08-27
- Implemented on:2021-03-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$175.00
Introduction
Analysis of Standard Technology Evolution
This standard replaces the 1997 version of SN/T 0654. The main technical upgrades are reflected in:
| Comparison dimensions | 1997 version | 2020 version |
|---|---|---|
| Number of detected compounds | 8 | 14 |
| Detection technology | Conventional GC | Heart-cutting-2D GC |
| Lower limit of quantification | 2 mg/kg | 0.4 mg/kg |
| Separation efficiency | Single column separation | Dual column synergistic separation |
Core method principle
Two-dimensional separation is achieved by using microfluidic plate heart-cutting system:
- Pre-column separation stage: Non-polar pre-column (30m×530μm) is used to initially separate light hydrocarbon components
- Heart-cutting stage: Switch to the analytical column (Lowox column) at t1=1.05min
- Backflush stage: t2=3.10min to vent the heavy hydrocarbon components
Key instrument configuration
Typical chromatographic condition case: Shenzhen Customs Laboratory uses Agilent 7890B system, equipped with FID detector (250°C), carrier gas pressure 55 kPa, split ratio 2:1, column temperature program 50°C (1 min) → 10°C/min → 250°C (4 min).
Key points of quality control
| Control items | Requirements |
|---|---|
| Stability of standard solution | Prepare and use immediately (especially alcohols) |
| Retention time deviation | ≤±0.05min |
| Repeatability limit (2mg/kg) | 0.2-0.5mg/kg |
Implementation suggestions
- Chromatographic column aging: New columns need to be aged at 250℃ for more than 12 hours
- Cutting time calibration: It is recommended to verify t1/t2 with ethyl tert-butyl ether standard every week
- Sample storage: Store at 0-5℃ away from light, and complete the test within 24 hours after opening

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

SN 0283-1994 in English
\"Method for Inspection of Dichlorodipyridinol Residues in Exported Poultry Meat\"
1994-02-18 -

SN/T 2946-2011 in English
Determination of the Vinyl Acetate Content of Ethylene-vinyl Acetate Copolymers - Fourier Transform Infrared Spectroscopy
2011-05-31 -

SN/T 3293-2012 in English
Detection and identification of narcissus mosais virus, narcissus latent virus and narcissus yellow stripe virus
2012-10-23 -

SN/T 2389.16-2016 in English
Rules for measurement survey on import and export commodities—Part 16:General regulation for static measurement in vertical cylindrical metal shore tanks
2016-12-12 -

SN/T 4445.2-2016 in English
Technical requirements for the inspection of medical apparatus for import-Part 2: Patient monitor
2016-06-28 -

SN 184-1993 in English
\"Test Methods for Listeria Monocytogenes in Exported Foods\"
1993-10-08 -

SN/T 0244-1994 in English
\"General Rules for Inspection and Certification of Imported Mechanical and Electrical Instruments\"
1993-08-01