SN/T 5274-2020 in English
VALIDDynamic pressure measurement of shells projectile launching Sensor method
- Issued on:2020-08-27
- Implemented on:2021-03-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$117.00
Introduction
Technical background and evolution of the standard
As an industry standard for entry-exit inspection and quarantine, this standard fills the technical gap in the quantitative detection of dynamic pressure during the launch of fireworks shells. Compared with the traditional visual method, the application of the sensor method improves the measurement accuracy by 300%, and the data sampling frequency reaches 100kHz or more.
Core test system composition
| Components | Technical requirements | Safety indicators |
|---|---|---|
| Launching tube | Medium carbon steel material, wall thickness>2mm | Inner diameter tolerance±1~4mm |
| Pressure sensor | Range 0-30MPa | Withstand high temperature of 150℃ |
| Data acquisition system | Sampling frequency ≥100kHz | Remote trigger ≥120m |
Analysis of key technical parameters
Emission pressure measurement
The peak value of the pressure curve is recorded by piezoelectric sensor, and the maximum value is obtained after 5 repeated tests. Typical launch pressure range of fireworks: 2-15MPa.
Emission impulse calculation
Use the integral formula I=πD²/4×∫P(t)dt, where the measurement accuracy of the tube diameter D must reach 0.1mm. The measured data of a 75mm fireworks shell shows: the rising edge time is 8-12ms, and the falling edge time is 15-20ms.
Key points for safe implementation
- Must be equipped with a remote detonator (control distance ≥120m)
- The sample storage volume does not exceed the load limit of the protective facilities
- The total resistance of the electric ignition head must be ≤3Ω
Standard application recommendations
Note when implementing: ①Preferably use sensors with M20×1.5 threaded interface ②Set the sampling time to ≥5s ③Terminate the test when the bullet diameter deviation exceeds ±4mm. The laboratory needs to establish a regular calibration system for pressure sensors, and it is recommended to use a piston pressure gauge for calibration after every 50 tests.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

SN 0283-1994 in English
\"Method for Inspection of Dichlorodipyridinol Residues in Exported Poultry Meat\"
1994-02-18 -

SN/T 1249-2015 in English
Assessing standard of sanitary supervision for entry-exit aircrafts
2015-09-02 -

SN/T 1667.2-2007 in English
Inspection of mechanical and electrical commodity for import and export - Part 2: Measurement of electrical & optical performance for color liquid crystal display devices
2007-12-24 -

SN/T 2798-2011 in English
Determination of Phenol Residues in Royal Jelly for Import and Export - High Performance Liquid Chromatography Method
2011-02-25 -

SN/T 4509.1-2016 in English
Rules for inspection of export audio, video and similar electronic apparatus General requirements
2016-06-28 -

SN/T 1938-2007 in English
Quarantine protocol for chalkbrood disease of bees
2007-08-06 -

SN/T 1558-2017 in English
Quarantine protocol for avain encephalomyelitis
2017-05-12 -

SN/T 2294.4-2011 in English
Inspection and Quarantine Laboratory Management. Part 4: Rules for the Laboratory Accident Disposal
2011-09-09 -

SN/T 0917-2010 in English
Method for the organoleptic examination on quality of tea for import and export
2010-05-27 -

SN/T 5571-2023 in English
Sampling guidelines of solid wastes for identification
2023-05-05