Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
bpa detection plasmon resonance method validation data validation itemsrequirementsmeasured data precision rsd≤25 % method introduction technical background elementstraditional hplc methodspr method detection automatic water quality system four mixing end point judgment
SN/T 5287-2021 in English

SN/T 5287-2021 in English

VALID

Textiles for import and export - Determination of bisphenol A (BPA) - Surface plasmon resonance (SPR) method

  • Issued on:2021-11-22
  • Implemented on:2022-06-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $180.00
$175.00


Introduction

Technical Background and Evolution of Standards

With the strengthening of global control over chemical residues in textiles, bisphenol A (BPA) has been listed as a key monitored substance as a typical environmental hormone. Traditional detection methods such as HPLC have problems such as complex pre-treatment and high cost. This standard applies surface plasmon resonance to textile BPA detection for the first time, achieving a high-sensitivity determination of 0.02 mg/kg.


Analysis of core principles

Technical elementsTraditional HPLC methodSPR method
Detection mechanismChromatographic separation + UV detectionAntigen-antibody specific binding
Sample pretreatmentComplex purification stepsMethanol ultrasonic extraction
Detection limit0.05 mg/kg0.02 mg/kg
Single sample detection time≥30 minutes≤20 minutes

Key Operation Specifications

1. Chip Modification Process

The use of CM5 chip must strictly follow the three-step modification method of activation (EDC/NHS mixture) → coupling (BPA-BSA antigen) → blocking (BSA solution), and the flow rate is controlled at 10 μL/min.

2. Standard Curve Establishment

The BPA concentration gradient is required to be 10n μg/L (n=0-10), and the four-parameter Logistic curve fitting is used, and the correlation coefficient R2 should be ≥0.99.


Implementation Difficulties and Solutions

Case: In a laboratory, the signal attenuation after chip regeneration was more than 20%. After investigation, it was found that the glycine-hydrochloric acid solution (pH3.6) was not replaced in time. It is recommended to update the regeneration solution every 50 tests or every week.

Method Validation Data

Validation ItemsRequirementsMeasured Data
Precision RSD≤25%18.7%
Spike Recovery80-120%92.3-105.6%
Chip Service LifeSignal Attenuation≤20%Average 35 times

Industry Application Recommendations

1. It is recommended to include BPA in the routine testing items for textiles exported to the EU;
2. When selecting an SPR instrument, verify its temperature control accuracy (±0.1°C);
3. Establish a daily calibration system for chip performance and record baseline drift values.