Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
glycol-type gas dehydration units scopethis standard conventional glycol-type natural gas dehydration units dehydration units flange design pressure dehydration device standard dehydration device shale gas resources bump products medical observation
SY/T 0602-2005 in English

SY/T 0602-2005 in English

VALID

Specification for glycol-type gas dehydration units

  • Issued on:2005-07-26
  • Implemented on:2005-10-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $780.00
$757.00

本标 准 阐 述了以三甘醇作为吸收剂的常规甘醇型天然气脱水装置(以下简称脱水装置)的材料、
设计、制造和试验的最低要求。常规脱水装置是指进料温度为15.560C-48.890C (600F一1200F),
操作压力大于或等于2.76 MPa(表压)(400psig),但不超过ANSIB 16.56 0016法兰设计压力下操作

的脱水装置。
本标 准 脱 水装置主要包括进料分离器、甘醇/天然气吸收塔、天然气/甘醇换热器、甘醇重沸器、
甘醇缓冲罐、甘醇循环泵、过滤器、贫富甘醇换热器、甘醇闪蒸分离器(可选)以及橇座。本标准也
可用于海上平台脱水装置的设计,但应满足海上平台装置的附加要求。
成 套 脱 水装置的制造商应负责保证所有材料、设计、制造程序,检验、验收以及试验均满足本标

准的要求


Scope

This standard describes the minimum requirements for materials, design, manufacturing and testing of conventional glycol-type natural gas dehydration units (hereinafter referred to as dehydration units) using triethylene glycol as the absorbent. Conventional dehydration devices refer to materials operating at 15.56℃~48.89℃ (60℉~120℉), operating pressure greater than or equal to 2.76MPa (gauge pressure) (400psig), but not exceeding ANSI B16.5 6001b flange design pressure Dehydration device. This standard dehydration device mainly includes a feed separator, a glycol/natural gas absorption tower, a natural gas/glycol heat exchanger, a glycol reboiler, a glycol buffer tank, a glycol circulation pump, a filter, and a rich-poor glycol exchanger. Heater, glycol flash separator (optional) and skid. This standard can also be used for the design of offshore platform dehydration devices, but the additional requirements for offshore platform devices should be met. The manufacturer of the complete set of dewatering equipment shall be responsible for ensuring that all materials, design, manufacturing procedures, inspection, acceptance and testing meet the requirements of this standard.

Sample only — not a preview of SY/T 0602-2005