SY/T 5796-2020 in English
VALIDEvaluation methods for flocculant used in oilfield
- Issued on:2020-10-23
- Implemented on:2021-02-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$97.00
Introduction
Interpretation of the core content of the standard
| Comparison dimensions | 1993 edition | 2020 edition |
|---|---|---|
| Terminology system | Separate chapter for "Terminology" | Upgraded to "Terminology and Definitions", with a new definition of 3.1 flocculants |
| Instruments and Equipment | 6 basic equipment | 18 new types of equipment including spectrophotometer and electric constant temperature water bath |
| Experimental methods | Single evaluation procedure | There are two methods: 6.1 one-time dosing and 6.2 multiple dosing |
Key technical points
4.1 Agitator specification
The standard clearly requires that the blades should be made of lightweight and corrosion-resistant materials, with a size of 60mm×20mm, a speed range of 0-140r/min, and the agitator shaft should be 6mm away from the center of the beaker to ensure uniform shear force distribution.
6.1.2 Dosing procedure
The speed is controlled in three stages: 120-140r/min pre-stirring for 30 seconds → maintaining 1min after rapid dosing → reducing the speed to 60r/min for 10min, simulating the gradient mixing process of on-site working conditions.
Implementation and application suggestions
- Water sample collection: A dry and insulated sampling bucket must be used to take ≥3L of raw water without flocculant. The valve must be flushed for 3-5 minutes before sampling. The experiment must be completed within 12 hours
- Oil content detection: Strictly follow the SY/T 0530 standard, and avoid disturbance when transferring 150mL of the upper clear liquid
- Equipment calibration: The wavelength accuracy (380-720nm) of the spectrophotometer must be calibrated regularly, and the electronic balance must maintain a sensitivity of 0.1mg
Analysis of standard evolution
The 2020 version deletes non-essential content such as the test tube rack structure diagram and evaluation report form in the 1993 version, and strengthens the scientific nature of the methodology:
- Added requirements for reagents such as n-hexane and nitrogen
- Introduced modern testing equipment such as microporous membrane filtration tester
- Specified that after standing for 30 minutes, the floating floc layer must be completely removed before sampling

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

SY/T 5429-1991 in English
Small diameter flow moisture tester
1992-01-15 -

SY 5282-1991 in English
Oil pumping rod card
1991-07-19 -

SY/T 6360-2022 in English
Safety code of practice for oilfield injection of polymer, lye, surfactant
2022-11-04 -

SY/T 6268-1996 in English
Recommended Practices for Selection of Tubing and Casing
1996-12-31 -

SY/T 5981-1994 in English
Exploration well oil testing operation procedures
1995-01-18 -

SY/T 5618-2016 in English
Float collar and float shoe for casing
2016-01-07 -

SY/T 7504-1994 in English
Gas Chromatography for Analysis of n-Octane and Previous Hydrocarbon Components in Crude Oil
1994-12-21 -

SY/T 5969-1994 in English
Specification for Interpretation of Gas Logging Data
1995-01-18