SY/T 7470-2020 in English
VALIDQuantification analysis method of diamondoids in crude oil
- Issued on:2020-10-23
- Implemented on:2021-02-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$243.00
Introduction
Standard Overview and Technical Background
As an important analytical method specification for the oil and gas industry, this standard establishes a standardized process for the quantitative detection of adamantane compounds in crude oil. As a maturity indicator and oil source comparison marker, adamantane compounds have special value in the field of oil and gas exploration. Compared with the previous version, the 2020 version of the standard mainly updates the technical parameter requirements and data processing algorithms of gas chromatography-mass spectrometer.
Core Instrument and Material Specifications
| Instrument Type | Technical Requirements | Key Parameters |
|---|---|---|
| Gas Chromatography-Mass Spectrometer | EI Ion Source | Resolution>500 |
| Chromatographic Column | 5% Phenyl Methyl Siloxane | Column Length≥30m |
| Internal Standard | Deuterated Monoadamantane | Purity≥98% |
Analysis of key operation procedures
Key points of sample preparation
Using isooctane ultrasonic extraction method, the oil sample weighing range is 10-20mg, and the centrifugal speed is 3000-5000r/min to ensure that the adamantane compounds are fully dissolved while avoiding the loss of light components by volatilization.
Instrumental analysis conditions
The chromatographic heating program adopts second-order gradient heating (initial 35-50℃, final temperature 300-320℃), and the mass spectrometry detection is recommended to use the selected ion monitoring mode (SIM) to improve the sensitivity, focusing on monitoring characteristic ions such as m/z 135, 149, and 163.
Quality Control System
The standard establishes strict quality control indicators:
- Blank test baseline noise needs to be ≤5% of the target response value
- Chromatographic peak separation requirement is ≥80%
- Calculation formula for repeatability limit r: r=0.0207m+1.0069
Implementation suggestions
1. Laboratories should regularly use standard substances to verify the response stability of the gas chromatography-mass spectrometry system
2. For complex samples, it is recommended to combine the mass chromatogram in Appendix B for co-elution peak identification
3. For highly waxy crude oil samples, the ultrasonic treatment time can be appropriately extended to 10 minutes

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

SY/T 5429-1991 in English
Small diameter flow moisture tester
1992-01-15 -

SY/T 5704-2012 in English
Specification for Calibration of Formation Dipmeter Logging Tool
2012-08-23 -

SY 4032.8-1993 in English
Standard for Quality Inspection and Evaluation of Petroleum Construction Engineering Telecommunication Engineering (Optical Fiber Digital Transmission System Engineering for the Telecommunication Net)
1993-11-26 -

SY/T 6140-1995 in English
Purchasing regulations for scale inhibitors used in the essential treatment of oilfield water injection
1995-12-25 -

SY/T 5538-1992 in English
Technical regulations for measurement of current status map of oil and gas transmission pipelines
1992-11-03 -

SY 5493-1992 in English
Fracturing equipment types and basic parameters
1992-09-17 -

SY/T 6006-1994 in English
Purchasing regulations for polyacrylamide used in well killing fluid
1995-01-18 -

SY/T 5940-2019 in English
Log computational method for parameters of reservoir
2019-11-04 -

SY 5288-1991 in English
Main connection dimensions of drilling hoisting equipment
1991-07-19 -

SY/T 5818-1993 in English
Soft salvage operation procedures
1993-09-09