Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
technical specification technical points standard technical elements preliminary survey detailed survey exploration point density specification specifies diffusion monitoring wells enterprise logistics cost pig hoof overall land use plans
SY/T 7680-2023 in English

SY/T 7680-2023 in English

VALID

Technical specification for petroleum contaminated site geotechnical investigation and remediation

  • Issued on:2023-05-26
  • Implemented on:2023-11-26
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $1,080.00
$1,048.00
Standard No: SY/T 7680-2023
Document status: VALID
Title in English: Technical specification for petroleum contaminated site geotechnical investigation and remediation
Title in Chinese: 石油类污染场地岩土工程勘察与修复技术规范
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 5 business days
Issued on: 2023-05-26
Implemented on: 2023-11-26
Professional Classification: SY-Oil & Gas
Related Keywords: technical specification
technical points
standard technical elements preliminary survey detailed survey exploration point density
specification specifies
diffusion monitoring wells
Related Topics: Contaminated site
Petro
Geotechnical Engineering
Geotechnical Engineering
Contaminated site
Method Petroleum
site
repair
polluted land pollution
land pollution pollution
Petroleum Test Methods
Petroleum Standards
oil
Petroleum Determination UV
Land Pollution+ Pollution
water qualitypetroleum-basedUV
water qualitypetroleum-basedUV
water qualitypetroleum-basedUV
CNPC
Classification of Contaminated Land
oil pollution
rock and soil
type of pollution
survey
repair technology
Geotechnical Investigation
oil pollution technology
observe
Ten Commandments of Land Pollution
Engineering Investigation
repair technology
Engineering Investigation
Geotechnical Investigation of Roller Compacted Earth-rockfill Dam
SY/T 7678-2023
SY/T 7694-2023
Geotechnical survey procedures for soft soil areas
sh/t 3159-2019 Petrochemical Geotechnical Engineering Survey
Petroleum Engineering Rock Mechanics
Petrochemical geotechnical engineering survey specification construction standard library
Woodland pollution remediation
Soil restoration project
Geotechnical Investigation Standards Classification of Earth and Rocks
sy/t 7699-2023
sy/t 7700-2023
sy/t 7702-2023
sy/t7698-2023
sy/t 7679-2023
sy/t 7698-2023
sy/t 7693-2023
Geotechnical Investigation Data Exchange
sy/t 7684-2023


Introduction

Analysis of the core content of the standard

Technical elements Preliminary survey Detailed survey
Exploration point density ≥3 points in the polluted area, grid spacing 40-100m ≥1 point per 400㎡, ≥5 points in the polluted area
Sampling depth Penetrating the polluted layer to enter the unpolluted layer≥2m
Groundwater monitoring wells ≥3 wells (including control wells) ≥5 wells (including diffusion monitoring wells)

Key technical points

1. Differentiated exploration strategy

The specification specifies three types of point distribution methods according to the characteristics of the pollution source: point pollution adopts radial distribution (spacing 10-20m), surface pollution adopts grid distribution (line spacing 10-20m), and line pollution adopts a combination of bilateral distribution modes.

2. Special requirements for soil sample collection

The case shows that when a refinery site uses a static pressure sampler to collect volatile organic compound samples, the parallel sample detection deviation is ≤15%, which is better than the impact sampling method. Special requirements of the specification:

  • VOCs samples should be collected first
  • Surface soil must be collected from 0-0.5m
  • Sampling interval at the pollution boundary ≤1m

Remediation technology implementation suggestions

Vertical barrier technology selection

When the depth of contaminated groundwater is less than 30m, it is recommended to use a combined process of high-pressure jet grouting wall (permeability coefficient ≤1×10⁻⁷cm/s) and solidification stabilization. A case study of an oil field shows that this combination reduces the concentration of downstream benzene by 92%.

Monitoring well construction specifications

The porosity of the filter pipe must meet the requirements of D10 filter material ≥D90 formation, the thickness of the quartz sand filter layer must be ≥50mm, and the turbidity of the well washing must be <50NTU. The wellbore structure diagram provided in Appendix B clarifies key parameters such as the opening diameter and the location of the filter pipe.


Analysis of Standard Evolution

Compared with SY/T 6620-2014, this specification has the following major improvements:

  1. Newly added differentiated detection requirements for petroleum hydrocarbons C6-C9/C10-C40
  2. Introduction of quantitative standards for engineering geophysical exploration technology (such as the resistivity method profile length ≥ 6 times the detection depth)
  3. Clearing the hierarchical relationship between risk control and restoration

Solutions to Common Problems

Q:How to avoid cross-contamination in multi-layer aquifers?
A:Article 5.2.6 of the specification requires the use of multi-stage casing for layered plugging, and the filter pipes of each layer shall not cross the layer, and the water-stopping material shall be filled to within 500mm of the ground.

Sample only — not a preview of SY/T 7680-2023