Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
1634.1-2004 plastics machining center scopethis standard standard materials hydrogen
T/BYXT 053-2023 in English

T/BYXT 053-2023 in English

VALID

Technical requirements for rare earth bimodal antibacterial and epidemic prevention

  • Issued on:2023-03-20
  • Implemented on:2023-04-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $230.00
$224.00
Standard No: T/BYXT 053-2023
Document status: VALID
Title in English: Technical requirements for rare earth bimodal antibacterial and epidemic prevention
Title in Chinese: 稀土双态抗菌防疫技术要求
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2023-03-20
Implemented on: 2023-04-01
Professional Classification: T/-Social Organization Standard
Related Topics: rare earth cluster
double antibody d
Double Antibody
Secondary antibody too dilute
Double Antibacterial
Double antifungal
Double Antibody
Double Antibody
Double Antifungal
Rare earth application technology
Double Antibody Requirements
Anti+Secondary Antibody+Dilution
Prevent double antibody
Rare Earth Capital
bimodal
Acid double antibody
Double Antibody 12-5
Double Antibacterial
Immunization double antibody
Rare earth mining
bispectral technique
Rare earth mining requirements
About rare earth
Flood prevention technical requirements
Rare earth material technology major
db 3306/t 053-2023
Thinner technology


Scope

5 Technical Requirements
5.1 Static Antimicrobial Technology Requirements
After the application or coating of rare earth antimicrobial materials on environmental surfaces, their static antimicrobial technical indicators for the surface are listed in Table 1.
Table 1 Static Antimicrobial Technical Indicators for Surfaces
Item Viral Inhibition Rate (%)a Antibacterial Rate (%)b Safetyc
Indicator 90.00-99.99 90.00-99.99 Non-toxic
a The test strain and number are SARS-COV-2 virus (WIVO4, GenBank: MN996528.1), with the testing method being the novel coronavirus inhibition plaque assay.
a The test strains and numbers are Staphylococcus aureus (ATCC 6538), Escherichia coli (8099), and Candida albicans (ATCC 10231). The patch testing method as specified in Section 5.2.6 of WS/T 650-2019 was used.
c Safety tests follow the methods specified in Chapter 1.4.3.2 of the Disinfection Technical Specifications.
5.2 Dynamic Disinfection and Purification Technology Requirements
After installing and running ion disinfection purifier equipment indoors, its technical indicators for dynamic air disinfection and purification within the effective coverage physical space are shown in Table 2.
Table 2 Technical Indicators for Airborne Dynamic Disinfection and Purification
Item Disinfectant Plasma Density Distribution (%)a Viral Inactivation (%)b Air Purification (mg/m3)c Safetyd
Project Virus Kill Natural Bacterial Elimination Formaldehyde Purification PM2.5 Purification
Indicator 2.63×10^14/m3-4.46×10^14/m3 90.00~99.99 ≤0.20 ≤0.05 Co-existence of humans and machines
a The test strain is SARS-COV-2 virus (WIVO4, GenBank: MN996528.1), with the testing method as specified in Section 2.1.3 of the Disinfection Technical Specifications for air disinfection effect certification.
b The natural bacterial strains are tested according to the methods specified in Appendix B of WS/T 648-2019.
c According to the indicators and test methods specified in GB/T 18883, Indoor Air Quality Standards.
d Product safety should comply with relevant regulations, norms, and standards stipulated by national laws. Electrical safety must meet the provisions of GB 4706.1, GB 4706.45, and GB 9706.1, while ozone leakage limits should conform to GB/T 18202, and a health permit number from the actual manufacturing enterprise must be obtained after evaluation as per Disinfectant Product Hygiene Safety Evaluation.
5.3 Dual-Mode Antimicrobial Epidemic Prevention Technology Requirements
The dual-mode antimicrobial epidemic prevention scenario constructed by combining the technologies in Sections 5.1 and 5.2 has technical requirements for both surface static antimicrobial and indoor air dynamic disinfection, which are listed in Table 3.
Table 3 Technical Requirements for Dual-Mode Antimicrobial Epidemic Prevention
Item Technical Requirementsa Test Methodsb
Quantity Inspection Qualification Inspection
1 Surface Static Antimicrobial SARS-COV-2 virus inhibition rate (%)
90.00-99.99 Viral antigen detection
Negative Simulation on-site or On-site test
2 Airborne Dynamic Disinfection and Purification The antimicrobial epidemic prevention technology requirements can be verified through quantity inspection and qualification inspection. Quantity inspections follow the testing methods specified in Tables 1 and 2, while qualification inspections use SARS-COV-2 virus antigen detection kits. For quantity inspections, the test strains should be SARS-COV-2 virus (WIVO4, GenBank: MN996528.1), with qualification inspections conducted on-site. Test methods can refer to relevant requirements in the Disinfection Technical Specifications.