Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
disinfection technique thermal disinfection evaluation system thermal disinfection parameters sanitary isolation washing medical fabrics comparison dimensions requirements graphic symbol flour milling industry scopethis standard furniture introduction background
WS/T 508-2016 in English

WS/T 508-2016 in English

VALID

Regulation for washing and disinfection technique of medical textiles in healthc are facilities

  • Issued on:2016-12-27
  • Implemented on:2017-06-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $220.00
$214.00

本标准规定了医院医用织物洗涤消毒的基本要求,分类收集、运送与储存操作要求,洗涤、消毒的原则与方法,清洁织物卫生质量要求,资料管理与保存要求。
本标准适用于医院和提供医用织物洗涤服务的社会化洗涤服务机构。
其他医疗机构可参照执行。


Introduction

Infection control standard system for medical fabrics

Comparison dimensions Requirements of this specification Internationally accepted standards Key differences
Classification management Clearly distinguish between three categories of infectious/dirty/clean fabrics Usually divided into infectious/non-infectious categories Add an intermediate level for dirty fabrics
Thermal disinfection parameters 75℃/30min or 80℃/10min 71℃/3min is generally used The time-temperature combination is more stringent
Microbial limit value ≤200CFU/100cm² No unified standard in many European and American countries The first quantitative indicator in China

Technical analysis of core terms

Sanitary isolation washing and drying equipment must meet 6 technical requirements such as double-door design and complete physical isolation. Its core indicators include:

  • Air pressure difference ≥5Pa
  • Door sealing test leakage rate <0.5%
  • Cross-contamination protection level must reach ISO 15883-1 Class S

Practical case of a tertiary hospital

After the implementation of the specification, the qualified rate of infectious fabric treatment increased from 82% to 98%, through:

  1. Configure tunnel-type washing unit to achieve continuous processing
  2. Establish a special transport system for orange-red infectious fabrics
  3. Use ATP bioluminescence detection method for process monitoring

Critical Control Point Implementation Guide

1. Special treatment of infectious fabrics

For fabrics contaminated with special pathogens such as prions, it is necessary to:

Pathogen type Pretreatment method Concentration/time
Prion Immerse in 1mol/L NaOH 60min
Gas gangrene Chlorine-containing disinfectant 2000-5000mg/L

2. Optimization of washing process parameters

Temperature control in the main wash stage must comply with:

  • Cotton fabric: 70-90℃
  • Chemical fiber fabric: ≤60℃
  • PH neutralization range: 5.8-6.5

Standard evolution and compliance recommendations

Compared with the 2002 version of the Technical Specifications for Disinfection, this standard has the following three breakthroughs:

  1. For the first time, the admission standards for socialized washing service agencies were clarified
  2. A thermal disinfection evaluation system with an A0 value ≥600 was introduced
  3. Building layout specifications for fabric turnover warehouses

Medical institutions should focus on improving:

  • Electronic traceability system for fabric handover
  • Quarterly microbiological monitoring mechanism
  • Maintenance records of washing equipment (including 500 cycle verification)

Sample only — not a preview of WS/T 508-2016
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • WS 843-2025 in English

    WS 843-2025 in English

    Medical equipment configuration standards for township health centers

    2025-03-29
  • WS/T 845-2024 in English

    WS/T 845-2024 in English

    Standards for bed transfer between the elderly care area and the medical area in medical and nursing institutions

    2024-07-24
  • WS/T 594-2018 in English

    WS/T 594-2018 in English

    Test methods of fly resistance to insecticides-A molecular method for detecting insensitive ace allele in the Musca domestica

    2018-03-01
  • WS/T 528-2016 in English

    WS/T 528-2016 in English

    Technical specifications for small centralized water supply disinfection

    2016-12-26