WS/T 535-2017 in English
VALIDRapid detection methods on site for disinfectant used in medical and health
- Issued on:2017-08-11
- Implemented on:2018-02-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$156.00
本标准规定了现场快速检测医疗卫生机构常用消毒剂有效成分含量及相关指标的方法、结果判定和注意事项。
本标准适用于利用消毒剂浓度试纸法测定过氧乙酸、二氧化氯、含氯、含溴、含碘消毒剂、酸性氧化电位水、戊二醛、邻苯二甲醛等常用消毒剂有效成分含量及其使用中浓度的限量值,以及利用现场快速检测仪器定量测定酸性氧化电位水、乙醇等有效成分和相关指标。
Introduction
Interpretation of the core content of the standard
This standard systematically standardizes the on-site rapid detection technology system for commonly used disinfectants in medical and health institutions for the first time, which mainly includes two detection methods:
| Detection method | Applicable objects | Detection accuracy | Judgment basis |
|---|---|---|---|
| Semi-quantitative method with test paper | 8 types of disinfectants such as peracetic acid | ±10% | Colorimetric card control |
| Instrumental determination method | Acidic oxidizing potential water/ethanol | ±5% | pH/ORP/specific gravity value |
Analysis of key technical requirements
4.1 Semi-quantitative determination method with test paper
The operating procedure strictly follows the three steps of immersion-colorimetry-judgment:
- The sample needs to be balanced at 25℃±2℃
- The test paper immersion time is controlled according to the instructions (usually 30-60 seconds)
- Colorimetry should be carried out immediately under natural light
Typical case: When testing glutaraldehyde disinfectant, if the color of the test paper does not reach 1.8% of the standard color, it must be stopped immediately and replaced with new liquid.
Implementation Recommendations
Key Points for Quality Control
- Test strips should be stored in a dark environment with a humidity of <60%.
- Acidic oxidation potential water detection requires three consecutive measurements after the water outlet stabilizes.
- Temperature correction is required when measuring using the ethanol specific gravity method (see Appendix B).
Analysis of Standard Evolution
Compared with the 2002 version of the Technical Specifications for Disinfection, this standard adds the following:
- Detection methods for new disinfectants such as o-phthalaldehyde.
- Standardized operating procedures for on-site rapid detection instruments.
- Clear criteria for determining limit values for different disinfectants.