Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
infection prevention outpatient department emergency department part-time infection control staff healthcare facilities introduction analysis door machines craftwork shoes foreword electromagnetic radiation levels
WS/T 591-2018 in English

WS/T 591-2018 in English

VALID

Regulation for prevention and control of healthcare associated infection in outpatient department and emergency department in healthcare facilities

  • Issued on:2018-05-10
  • Implemented on:2018-11-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $280.00
$272.00
Standard No: WS/T 591-2018
Document status: VALID
Title in English: Regulation for prevention and control of healthcare associated infection in outpatient department and emergency department in healthcare facilities
Title in Chinese: 医疗机构门急诊医院感染管理规范
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2018-05-10
Implemented on: 2018-11-01
ICS Classification: 11.020-Medical Sciences and health care facilities in general
Chinese Classification: C05-Medical science
Professional Classification: WS-Hygiene
Related Keywords: infection prevention
outpatient department
emergency department
part-time infection control staff
healthcare facilities introduction analysis
Related Topics: Infect
Medical institutions
Medical institutions
Nosocomial infection in Jianjiang Hospital of Traditional Chinese Medicine
About being in a medical institution
hospital instrument
hospital system
medical consultation box
Hospital range
diagnosis
Hospital Infection
Medical aftermath
medical door
medical door
The hospital breaks the five rules
Hospital Infection
multidrug resistance
medical tubing
three reasonable hospital
hospital cobalt
Hospital Xu
Diagnostic criteria for nosocomial infection (trial implementation)
WS/T404-2018
WS T 586 2018
Hospital air purification management
Medical heat sealing machine
ws591-2018

本标准规定了医疗机构门诊和急诊科(部、室)(以下简称门急诊)医院感染管理要求、宣教和培训、监测与报告、预检分诊、预防和控制感染的基本措施、基于传播途径的预防措施、医疗废物处置等。
本标准适用于提供门急诊服务的各级各类医疗机构。


Introduction

Analysis of the core content of the standard

This standard was issued by the National Health Commission in 2018, focusing on standardizing the infection prevention and control requirements in key areas such as the pre-examination and triage desk and consulting rooms in outpatient and emergency departments. The main technical indicators include:

Core elements Key requirements Implementation points
Organizational management Establish a hospital infection management team The team leader shall be the person in charge of the outpatient and emergency departments, and at least one part-time infection control staff shall be assigned
Zoning management Environmental risk classification High-risk areas include blood collection room, dental department, etc., and the frequency of disinfection needs to be increased
Personnel protection PPE usage specifications When exposed to droplet-borne diseases, wear a surgical mask + goggles.

Recommendations for the implementation of key measures

Optimization plan for pre-examination and triage

Taking the fever clinic of a tertiary hospital as an example, it should be equipped with:

  • Negative pressure clinic with independent ventilation system
  • Patient flow route with dual-channel design
  • Equipped with contactless hand hygiene facilities

Technology evolution analysis

Main upgrades compared with the previous version:

  1. Added mandatory use requirement for safety injection devices
  2. Refine the frequency of environmental surface cleaning (≥2 times/day in high-risk areas)
  3. Introduce the WHO hand hygiene monitoring method

Sample only — not a preview of WS/T 591-2018
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • WS 843-2025 in English

    WS 843-2025 in English

    Medical equipment configuration standards for township health centers

    2025-03-29
  • WS/T 845-2024 in English

    WS/T 845-2024 in English

    Standards for bed transfer between the elderly care area and the medical area in medical and nursing institutions

    2024-07-24
  • WS/T 594-2018 in English

    WS/T 594-2018 in English

    Test methods of fly resistance to insecticides-A molecular method for detecting insensitive ace allele in the Musca domestica

    2018-03-01
  • WS/T 528-2016 in English

    WS/T 528-2016 in English

    Technical specifications for small centralized water supply disinfection

    2016-12-26
  • WS/T 311-2023 in English

    WS/T 311-2023 in English

    Standard for isolation technique in hospitals

    2023-08-20
  • WS/T 508-2016 in English

    WS/T 508-2016 in English

    Regulation for washing and disinfection technique of medical textiles in healthc are facilities

    2016-12-27