XF 3009-2020 in English
VALIDRescue tripod
- Issued on:2020-11-10
- Implemented on:2021-05-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$194.00
| Standard No: | XF 3009-2020 |
| Document status: | VALID |
| Title in English: | Rescue tripod |
| Title in Chinese: | 救援三脚架 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 1~3 business days |
| Issued on: | 2020-11-10 |
| Implemented on: | 2021-05-01 |
| ICS Classification: | 13.220.10-Fire-fighting |
| Chinese Classification: | C85-Fire-fighting survival and auxiliary tools |
| Related Keywords: | rescue tripod introduction interpretation
class=instrument > rescue tripod strength test anti-slip performance support foot displacement ≤20mm nfpa electric winch power failure electric winch |
| Related Topics: | xf
foot tripod which tripod rescue save /xf xf/ Rescue floating stretcher Mine rescue stretcher standards |
本文件规定了救援三脚架的术语与定义、型号、技术要求、试验方法、检验规则以及包装、运输和贮存等。
本文件适用于在城市、山地、洞穴和井下环境进行抢险救援作业时使用的救援三脚架。
Introduction
Interpretation of the core content of the standard
| Technical dimensions | XF 3009-2020 requirements | Comparison with similar international standards | Technical breakthrough points |
|---|---|---|---|
| Structural strength | 3 times rated load test (≥450kg) | EN 795:2012 requires 2.5 times | New protection chain breaking strength test |
| Anti-slip performance | Support foot displacement ≤20mm | NFPA 1983 does not clearly quantify | The first dynamic operation displacement control |
| Functional accessories | 3 categories: monitoring/towing/survival supplies | ISO 22159 only contains basic functions | Integrated modular design |
Analysis of key technical requirements
Model compilation system
A four-level coding structure is adopted: ZYJS[winch type][load mass]/[lifting height][accessory code], such as ZYJSJD200/30JT means electric winch, 200kg load, 30m lifting height and includes monitoring + towing functions.
5 types of mandatory clauses
- Structural safety: 2 universal anchor points are required at the top, and the difference in length of the supporting legs is ≤5mm
- Corrosion resistance: No functional damage after 48h salt spray test
- Emergency braking: The electric winch automatically stops when overloaded by 130%
- Anti-slip displacement: The sliding of the supporting legs in continuous operation is ≤20mm
- Power failure emergency: The electric winch must be equipped with a manual emergency device
Functional accessories technical specifications
Monitoring system case
A certain type of The monitoring components of the class=instrument>rescue tripod must meet the following requirements: IP66 protection level, cable length ≥ rope length (standard 5.10.1.2), and quick buckles every 5m. In actual mountain rescue, this configuration can realize real-time video transmission from underground.
Recommendations for standard implementation
- Purchase verification: Focus on checking the winch wire rope diameter (≥4mm) and salt spray test report
- Maintenance points: Check the wear of the protective chain (belt) every month, and the breaking strength must be maintained at ≥10kN
- Training focus: Emergency operation of electric winch power failure (standard 5.5.2 requires the handle operating force to be ≤250N)

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

XF 869-2010 in English
Protective hood for firefighters
2010-05-31 -

XF 6-2004 in English
Exposure footwear for firemen
2004-06-04 -

XF 1273-2015 in English
Firefighter protective auxiliary equipment-Goggles for firefighters
2015-10-12 -

XF 3008-2020 in English
Anti-bee protective clothing for firefighters
2020-11-10 -

XF 44-2015 in English
Helmets for firemetn
2015-09-28 -

XF 632-2006 in English
Self-contained positive pressure 0xygen breathingapparatus for fire fighting
2006-08-29 -

XF 124-2013 in English
Self-contained positive pressure air breathing apparatus for fire-fighting
2013-07-26 -

XF 631-2006 in English
Fire rescue air-cushion
2006-08-29 -

XF 1298-2016 in English
Water mist fire nozzles
2016-05-18 -

XF 634-2015 in English
Adiabatic protective clothing for firefighter
2015-09-28