本标准规定了烟草中毒杀芬残留量的气相色谱测定法。本标准适用于烟草和烟草制品。
Introduction
Analysis of key points of standard technology
| Parameter type | Standard requirements | Optimization suggestions |
|---|---|---|
| Chromatographic column | DB-35 capillary column(30m×0.32mm×0.25μm) | DB-5MS column can be tested for comparative verification |
| Detector | Electron capture detector (ECD) | Base flow value is recommended to be set at 1-5pA |
| Temperature program | 110℃→320℃(15℃/min) | The initial time can be extended to 1min |
Key operation process
- Sample preparation: 5g sample and Florisil are loaded in layers, and Soxhlet extractor is extracted with n-hexane for 4.5h
- Chromatographic conditions: carrier gas linear velocity 45cm/s, injection port 250℃/detector 350℃
- Method validation: recovery rate needs to be >95% (dieldrin validation)
Technology evolution analysis
This standard adopts the mainstream technology in 2004:
- Pretreatment: Retain traditional Soxhlet extraction, and the current method mostly adopts accelerated solvent extraction (ASE)
- Detection limit: 0.1μg/mL, the current instrument sensitivity can be increased by 10 times
- Chromatographic column: DB-35 stationary phase is now mostly replaced by DB-35MS with similar polarity
Implementation Notes
A case from a testing center shows that when florisil is not sufficiently activated, the recovery rate of toxaphene will drop below 80%. Suggestions:
- Strictly follow clause 4.5.2 and activate at 550℃ for 5 hours
- Perform dieldrin recovery verification for each batch
- Control the ambient humidity to <40%RH
Extended application of standards
This method has been proven to be applicable to:
- Pesticide control in tobacco planting process
- Import inspection of tobacco products
- Organic tobacco certification testing

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

YC/T 565-2018 in English
General guidelines for establishing sensory analysis laboratories for tobacco and tobacco products
2018-01-18 -

YC/T 146-2025 in English
Tobacco Leaf Processing and Re-drying Technical Specifications
2025-06-30 -

YC/T 250-2008 in English
Tobacco and tobacco products—Determination of mercury arsenic lead—Hydride atomic fluorescence spectrophotometry
2008-04-14 -

YC/T 523-2015 in English
Management and control procedure on good agriculture of tobacco
2015-01-26