YD/T 3980-2021 in English
VALIDTechnical requirements and test methods for cold plate liquid cooling server system of data center
- Issued on:2021-12-02
- Implemented on:2022-04-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$243.00
| Standard No: | YD/T 3980-2021 |
| Document status: | VALID |
| Title in English: | Technical requirements and test methods for cold plate liquid cooling server system of data center |
| Title in Chinese: | 数据中心冷板式液冷服务器系统技术要求和测试方法 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 1~3 business days |
| Issued on: | 2021-12-02 |
| Implemented on: | 2022-04-01 |
| Professional Classification: | YD-Telecommunication |
| Related Topics: | Test center to test method
server liquid center technology Test center system Technology Center Program liquid cooling YD/T 5167-2021 Cold plate liquid cooling Liquid cooling plate industry dry cooler Liquid-cooled server technology yd/t202408-2021 Cold plate liquid cooling general technology Water cooling plate test yd/t3980-2021 |
本文件规定了数据中心冷板式液冷服务器系统的服务器、CDU 和其他相关方面的技术要求与测试方法。
本文件适用于冷板式液冷服务器系统的设计、施工、部署、运维、测试等环节的技术指导。
Introduction
Core Technology Innovation and Standard Framework
This standard systematically defines the application specifications of cold plate liquid cooling technology in data centers for the first time. Through the standardized design of key components such as liquid cooling cabinets and CDU, the PUE value can be reduced by more than 30%. The main breakthroughs are reflected in:
| Technical Dimensions | Traditional Air Cooling | Cold Plate Liquid Cooling | Efficiency Improvement |
|---|---|---|---|
| Heat Dissipation Density | ≤15kW/Cabinet | ≥40kW/Cabinet | 167% |
| Noise Level | 75dB | 45dB | 40% Noise Reduction |
| Energy Consumption Ratio | 35-45% | 8-12% | 70% energy saving |
Analysis of key technologies of liquid cooling system
1. Cold plate liquid cooling architecture
The system adopts a three-stage heat exchange architecture: chip→cold plate→CDU→cooling tower, among which the water distribution manifold must meet the following requirements:
- Branch flow deviation ≤5%
- Pressure bearing capacity ≥1.5MPa
- Quick connector plug-in life ≥5000 times
2. Coolant parameter specifications
Key indicators of secondary side coolant:
| Parameter | Required value | Test method |
|---|---|---|
| pH value | 6.5-8.0 | Electrode method |
| Chloride | ≤50ppm | Ion chromatography |
| Total bacteria count | ≤1000CFU/ml | Plate culture |
Implementation suggestions and risk control
1. Deployment strategy
It is recommended to adopt the W3 temperature level (2-32℃) solution to balance the initial investment and operating costs:
- North China: Cooling tower + dry cooler hybrid mode
- South China: Chiller auxiliary operation
2. Key points of operation and maintenance
A three-level monitoring system must be established:
- Real-time monitoring of CDU inlet and outlet pressure difference (threshold ±15%)
- Monthly water quality testing (focus on copper ions ≤0.1ppm)
- Quarterly pipeline air tightness testing
Technology evolution trend
The next generation technology will develop towards two-phase immersion, and the current standard has reserved interfaces:
- CDU supports high-temperature return water above 45°C (W5 level)
- Liquid cooling joints are compatible with dielectric fluids
- The monitoring system adds a phase change detection module

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

YD/T 0837.4-1996 in English
Test methods for copper-polyolefin-core insulated aluminum-plastic composite sheathed local copper-core cables
1996-04-04 -

YD/T 892-1997 in English
Detail bill for express mail service
1997-03-04 -

YD 609-1993 in English
Setup and Adjustment Limits for Mixed Digital-Analog Telephone Circuits
1993-01-18 -

YDN 126-2007 in English
Baseline Requirements for Network and Information Security of Value-added Telecommunication Services
2007-11-14 -

YD/T 2799.2-2015 in English
Technical specification of integrated intradyne coherent receiver Part 2:100Gbit/s
2015-04-30 -

YD/T 3826-2021 in English
General Technical Requirements for Slicing Packet Network (SPN )
2021-03-05 -

YD/T 883-1996 in English
900MHz TDMA digital cellular mobile communication network base station wireless equipment technical specifications and test methods
1996-12-04 -

YD/T 3296.2-2018 in English
Multicore and symmetrical pair,polyolefin insulate outside plant cables for digital communications-Part 2:Unfilled cable
2018-12-21 -

YD/T 2317.4-2011 in English
MPLS Multicast Technical Specification - Part 4: Technical Requirement for Service Interface Between MPLS Multicast and Multicast Virtual Private Network
2011-05-18 -

YD/T 839.4-1996 in English
Optical Cable filling and coating composite Part 4: composite coating
1996-04-04