Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
radio frequency hyperthermia equipment introduction background operating frequency range new frequency stability requirement frequency meter multi-point monitoring temperature control accuracy ±1℃ ±0.5℃ accuracy liquid radioactive effluents auxiliary filter cubicle rubber-surface rubber shoes
YY 0777-2023 in English

YY 0777-2023 in English

VALID

Radio frequency hyperthermia equipment

  • Issued on:2023-01-13
  • Implemented on:2026-01-15
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $160.00
$156.00
Standard No: YY 0777-2023
Document status: VALID
Title in English: Radio frequency hyperthermia equipment
Title in Chinese: 射频热疗设备
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2023-01-13
Implemented on: 2026-01-15
Superseding: YY 0777-2010 Radio frequency hyperthermia equipment
Professional Classification: YY-Pharmaceutics
Related Keywords: radio frequency hyperthermia equipment introduction background
operating frequency range
new frequency stability requirement
frequency meter
multi-point monitoring temperature control accuracy ±1℃ ±0.5℃ accuracy
Related Topics: RF equipment use
RF equipment
RF equipment
therapy
hyperthermia
treatment+
frequency
Frequency+
bluetooth radio frequency device
RF heater
RF instrument design
Medical RF equipment accessories
Radiofrequency hyperthermia equipment industry

本文件规定了射频热疗设备的要求和试验方法。
本文件适用于射频热疗设备。
本文件不适用于射频消融设备。


Introduction

Background of Standard Revision and Technology Evolution

This standard, as an alternative version of YY 0777-2010, reflects the development achievements of radiofrequency thermal therapy technology over the past decade. It mainly deletes non-core clauses such as appearance inspection and composition structure, and strengthens key technical indicators such as output power accuracy (±20%) and temperature control (±0.5℃).


Comparison of core technical requirements

Technical parameters 2010 version requirements 2023 version requirements Range of change
Output power error Not specified ≤±20% New quantitative indicators
Temperature measurement channels Unspecified number ≥5 channels Add multi-point monitoring
Temperature control accuracy ±1℃ ±0.5℃ Accuracy improved by 50%

Details of key technical specifications

1. Electromagnetic parameter requirements

The operating frequency range remains 3MHz-120MHz, but a new frequency stability requirement is added (nominal value ±2%). The test needs to be measured at rated power using a frequency meter (accuracy ±0.5%).

2. Temperature control system

Use fiber optic thermometer (accuracy ±0.1℃) as the standard reference, and require the equipment to:

  • Equipped with automatic temperature control mode
  • Settings above 45℃ require special operation to unlock
  • Temperature fluctuation curve recording interval ≤ 1 minute

Safety protection mechanism

Typical safety design case: When the temperature measurement channel is abnormal or the communication is interrupted, the system needs to alarm at a sound pressure level of 60dB(A) and automatically cut off the RF output, and the visual warning needs to continue until manual reset. The emergency stop device must meet the requirement of single action to cut off all power sources.

Implementation suggestions

  1. Upgrade the power calibration system to ensure that the power output error within the full range is ≤±15% (reserve a 5% margin)
  2. Use a distributed temperature sensing network, and it is recommended to configure 8-10 temperature measurement points (exceeding the minimum standard requirement)
  3. Electromagnetic compatibility design must meet the dual requirements of GB 9706.1 and GB 9706.203-2020