The difference between closed and open flash point determination methods
The difference between closed and open flash point determination methods, Total:127 items.
The international standard classification for "The difference between closed and open flash point determination methods" includes: Petroleum products in general , Pesticides and other agrochemicals , Paints and varnishes , Protection against dangerous goods .
The Chinese standard classification for "The difference between closed and open flash point determination methods" includes: Fragrances and flavors , Petroleum products in general , Basic standards and general methods for pesticides , Basic standard and general method for coating , Marking, packaging, transport and storage in general .
Professional Standard - Commodity Inspection
- SN/T 0735.15-1999 Export of aromatic oils|| and synthetic fragrances from a single assay flash point (closed cup)
- SN/T 2939-2011 Determination of Flash Point of Petroleum Products - Pensky-Martens Closed Cup Tester
- SN/T 0801.12-1999 Animal and vegetable oils and fats for import and export - Method for the determination of flash point-Closed cup method
- SN/T 3077.1-2012 Test method for flash point by continuously closed cup tester
- SN/T 735.15-1999 Determination of flash point of aromatic oils, isolated and synthetic fragrances for export (closed cup method)
Professional Standard - Petrochemical Industry
- SH/T 0315-1992 Technical condition for closed flash recogizer
- SH/T 0768-2005 Test method of flash point by continuously closed cup tester
- SH/T 0733-2004 Test method for flash point by tag closed cup tester
未注明发布机构
- AS 2106.6:2005(R2016) Methods for the determination of the flash point of flammable liquids (closed cup) - Determination of flash point - Closed cup equilibrium method
- AS 2106.2:2005(R2016) Methods for the determination of the flash point of flammable liquids (closed cup) - Determination of flash point - Pensky-Martens closed cup method
- DIN EN ISO 3679 E:2022-05 Determination of flash point Methods for determining flash point, no flash point and flash point using a small closed cup tester (draft)
- AS 2106.4:2005(R2016) Methods for the determination of the flash point of flammable liquids (closed cup) - Determination of flash point - Rapid equilibrium closed cup method
- DIN EN ISO 13736 E:2020-05 Determination of flash point Abel closed cup method (draft)
- DIN EN ISO 3679 E:2013-10 Determination of flash point Methods for determining flash point, no flash point and flash point using a small closed cup tester (draft)
- AS 2106.3:2005(R2016) Methods for the determination of the flash point of flammable liquids (closed cup) - Determination of flash/no flash - Rapid equilibrium closed cup method
- DIN EN ISO 13736:2021 Determination of flash point - Abel closed-cup method
- DIN EN ISO 13736 E:2011-06 Determination of flash point Abel closed cup method (draft)
- AS 2585:2006(R2016) Determination of flash and fire points - Cleveland open cup method
- DIN EN ISO 2719 E:2015-07 Determination of flash point: Bin-Martens closed cup flash point determination method (draft)
- AS 2106.5:2005(R2016) Methods for the determination of the flash point of flammable liquids (closed cup) - Determination of flash/no flash - Closed cup equilibrium method
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
- GB/T 6753.5-1986 Coatings and related products--Determination of flashpoint--Closed cup equilibrium method
- GB/T 21789-2008 Petroleum products and other liquids - Determination of flash point -Abel closed cup method
- GB/T 261-1983 Petroleum products;Determination of flash point;Closed cup method
- GB/T 14454.10-1993 Aromatics. Determination of flash point. Closed cup method
- GB/T 261-2008 Determination of flash point - Pensky-Martens closed cup method
- GB/T 3776.5-1983 Method of flash point determination (closed cup test) for pesticide emulsifiers
- GB/T 21929-2008 Test method for flash point by tag closed cup tester
- GB/T 27848-2011 Liquid asphalt and derivatives - Determination of flash point - Abel closed tester
- GB/T 27847-2011 Petroleum products - Determination of flash point - Abel-Pensky closed tester
Professional Standard - Agriculture
- GB 3776.5-1983 Method for determination of flash point of pesticide emulsifier (closed cup method)
Professional Standard - Electricity
- DL/T 1354-2014 The Method of Flash Point of Power Oil by Microscale Continuously Closed up Tester
National Metrological Technical Specifications of the People's Republic of China
- JJF 1384-2012 Calibration Specification for Open/Closed Cup Flash Point Testers
国家市场监督管理总局、中国国家标准化管理委员会
- GB/T 261-2021 Determination of flash point—Pensky-Martens closed cup method
Group Standards of the People's Republic of China
- T/SPSTS 016-2021 Determination of flash point for battery electrolyte --Abel closed cup method
- T/CSTM 00258-2021 Determination of flash point for battery electrolyte --Abel closed cup method
German Institute for Standardization
- DIN EN ISO 2719:2003 Determination of flash point - Pensky-Martens closed cup method (ISO 2719:2002); German version EN ISO 2719:2002
- DIN EN ISO 3679:2023 Determination of flash point - Method for flash no-flash and flash point by small scale closed cup tester (ISO 3679:2022)
- DIN EN ISO 13736:2009 Determination of flash point - Abel closed-cup method (ISO 13736:2008); German version EN ISO 13736:2008
- DIN EN ISO 3679:2023-03 Determination of flash point - Method for flash no-flash and flash point by small scale closed cup tester (ISO 3679:2022); German version EN ISO 3679:2022
- DIN EN ISO 2719:2016 Determination of flash point - Pensky-Martens closed cup method (ISO 2719:2016); German version EN ISO 2719:2016
- DIN EN ISO 1516 Berichtigung 1:2006 Determination of flash/no flash - Closed cup equilibrium method (ISO 1516:2002); German version EN ISO 1516:2002, Corrigenda to DIN EN ISO 1516:2002-08
Association Francaise de Normalisation
- NF EN ISO 3679:2022 Flash Point Determination - Pass/No Pass Flash Method and Small-Scale Closed Cup Flash Point Method
- NF M07-019*NF EN ISO 2719:2018 Determination of flash point - Pensky-Martens closed cup method
- NF M07-011:2008 Determination of flash point - Abel closed-cup method.
- NF M07-011:2013 Determination of flash point - Abel closed-cup method
- NF T60-616*NF EN ISO 3679:2015 Determination of flash no-flash and flash point - Rapid equilibrium closed cup method
- NF T60-614*NF EN ISO 1516:2002 Determination of flash/no flash - Closed cup equilibrium method
American Society for Testing and Materials (ASTM)
- ASTM D3143-08 Standard Test Method for Flash Point of Cutback Asphalt with Tag Open-Cup Apparatus
- ASTM D92-12b Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester
- ASTM D92-12a Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester
- ASTM D3828-97 Standard Test Methods for Flash Point by Small Scale Closed Tester
- ASTM D3828-16a Standard Test Methods for Flash Point by Small Scale Closed Cup Tester
- ASTM D3828-98 Standard Test Methods for Flash Point by Small Scale Closed Tester
- ASTM D92-11 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester
- ASTM D3934-90(2007) Standard Test Method for Flash/No Flash Test-Equilibrium Method by a Closed-Cup Apparatus
British Standards Institution (BSI)
- BS EN ISO 13736:2009 Determination of flash point. Abel closed-cup method
- BS EN ISO 13736:2021 Determination of flash point. Abel closed-cup method
- BS EN ISO 13736:2008 Determination of flash point - Abel closed-cup method
- BS EN ISO 13736:2013 Determination of flash point. Abel closed-cup method
- BS EN ISO 3679:2022 Determination of flash point. Method for flash no-flash and flash point by small scale closed cup tester
- BS EN ISO 13736:1998 Petroleum products and other liquids - Determination of flash point - Abel closed cup method
- 22/30441177 DC BS EN ISO 3679. Determination of flash point Method for flash no-flash and flash point by small scale closed cup tester
- BS EN ISO 3679:2015 Determination of flash no-flash and flash point. Rapid equilibrium closed cup method
Danish Standards Foundation
- DS/EN ISO 2719:2003 Determination of flash point - Pensky-Martens closed cup method
- DS/EN 22719:1994 Petroleum products and lubricants. Determination of flash point. Pensky-Martens closed cup method
- DS/EN ISO 2592:2001 Determination of flash and fire points - Cleveland open cup method
- DS/EN ISO 3680:2004 Determination of flash/no flash - Rapid equilibrium closed cup method
IT-UNI
- UNI EN ISO 2719:2021 Determination of flash point - Pensky-Martens closed cup method
Standard Association of Australia (SAA)
- AS 2585:2006 Determination of flash and fire points - Cleveland open cup method
- AS 2106.5:2005 Methods for the determination of the flash point of flammable liquids (closed cup) - Determination of flash/no flash - Closed cup equilibrium method
- AS 2106.3:2005 Methods for the determination of the flash point of flammable liquids (closed cup) - Determination of flash/no flash - Rapid equilibrium closed cup method
- AS 2106.2:2005 Methods for the determination of the flash point of flammable liquids (closed cup) - Determination of flash point - Pensky-Martens closed cup method
- AS 2106.6:2005 Methods for the determination of the flash point of flammable liquids (closed cup) - Determination of flash point - Closed cup equilibrium method
- AS 2106.4:2005 Methods for the determination of the flash point of flammable liquids (closed cup) - Determination of flash point - Rapid equilibrium closed cup method
NL-NEN
- NEN 5328-1972 Paints. Determination of flashpoint (closed cup method)
- NEN-ISO 2719:1994 Petroleum products and lubricants. Determination of flash point. Pensky-Martens closed cup method (ISO 2719:1988)
International Organization for Standardization (ISO)
- ISO 13736:2013 Determination of flash point - Abel closed-cup method
- ISO 13736:2008 Determination of flash point - Abel closed-cup method
- ISO 13736:2021 Determination of flash point - Abel closed-cup method
- ISO 3679:2022 Determination of flash point – Method for flash no-flash and flash point by small scale closed cup tester
- ISO 13736:1997 Petroleum products and other liquids - Determination of flash point - Abel closed cup method
- ISO 2592:2000 Determination of flash and fire points - Cleveland open cup method
European Committee for Standardization (CEN)
- EN ISO 13736:2021 Determination of flash point - Abel closed-cup method (ISO 13736:2021)
- EN ISO 13736:2013 Determination of flash point - Abel closed-cup method (ISO 13736:2013)
- EN ISO 13736:2008 Determination of flash point - Abel closed-cup method
- EN ISO 2719:2016 Determination of flash point - Pensky-Martens closed cup method (ISO 2719:2016)
- EN ISO 2719:2016/A1:2021 Determination of flash point - Pensky-Martens closed cup method - Amendment 1: Thermometers correction (ISO 2719:2016/Amd 1:2021)
- EN ISO 13736:2021/A1:2022 Determination of flash point - Abel closed-cup method - Amendment 1: Bias statement update (ISO 13736:2021/Amd 1:2022)
- EN ISO 1516:2002 Determination of flash/no flash - Closed cup equilibrium method (ISO 1516:2002)
Japanese Industrial Standards Committee (JISC)
- JIS K 2265-1:2007 Determination of flash point -- Part 1: Tag closed cup method
- JIS K 2265-3:2007 Determination of flash point -- Part 3: Pensky-Martens closed cup method
- JIS K 2265-2:2007 Determination of flash point -- Part 2: Rapid equilibrium closed cup method
SE-SIS
- SIS 15 51 25-1964 Oils. Determination of flash and fire points by Cleveland open cup
- SIS SS-ISO 2719:1990 Petroleum products and lubricants — Determination of flash point — Pensky-Martens closed cup method
ES-UNE
- UNE-EN ISO 3679:2023 Determination of flash point - Method for flash no-flash and flash point by small scale closed cup tester (ISO 3679:2022, Corrected versión 2023-05)
- UNE-EN ISO 3679:2015 Determination of flash no-flash and flash point - Rapid equilibrium closed cup method (ISO 3679:2015)
SCC
- DANSK DS/ISO 3679:2022 Determination of flash point – Method for flash no-flash and flash point by small scale closed cup tester
- DANSK DS/EN ISO 3679:2015 Determination of flash no-flash and flash point – Rapid equilibrium closed cup method
- AS/NZS 2106.6:1999 Methods for the determination of the flash point of flammable liquids (closed cup), Part 6: Determination of flash point - Closed cup equilibrium method
- AENOR UNE 21320-12:1989 Fluids for electrotechnical applications. Determination of the flash and combustion points of mineral oils in an open glass.
- AS/NZS 2106.5:1999 Methods for the determination of the flash point of flammable liquids (closed cup), Part 5: Flash/no flash test - Closed cup equilibrium method
- NS-ISO 2719:1988 Petroleum products and lubricants — Determination of flash point — Pensky-Martens closed cup method
- AENOR UNE-EN ISO 3679:2015 Determination of flash no-flash and flash point - Rapid equilibrium closed cup method (ISO 3679:2015)
- NS-EN ISO 3679:2015 Determination of flash no-flash and flash point - Rapid equilibrium closed cup method (ISO 3679:2015)
- NS-EN ISO 3679:2022 Determination of flash point - Method for flash no-flash and flash point by small scale closed cup tester (ISO 3679:2022, Corrected version 2023-05)
- NS-ISO 2592:2000 Determination of flash and fire points — Cleveland open cup method
VN-TCVN
- TCVN 7485-2005 Petroleum products.Test method for flash point by Tag closed cup tester
- TCVN 2693-2007 Petroleum Products.Test methods for determination of flash point by Pensky-Martens closed cup tester
GOSTR
- GOST 33192-2014 Petroleum products and other liquids. Method for determination of flash point by tag closed cup tester
- GOST ISO 13736-2009 Petroleum products and other liquids. Determination of flash point by Abel closed cup method
RO-ASRO
- STAS 11196-1979 PAINTS AND VARNISHES Determination of the danger classification by flashpoint (closed cup method),
GSO
- BH GSO ISO 3679:2017 Determination of flash no-flash and flash point -- Rapid equilibrium closed cup method
- GSO ISO 3679:2016 Determination of flash no-flash and flash point -- Rapid equilibrium closed cup method
- GSO 501:1994 Paints and Varanishes - Methods of test - Determination of flash point - (Closed Cup Method ).
- OS GSO 501:1994 Paints and Varanishes - Methods of test - Determination of flash point - (Closed Cup Method ).
- GSO ISO 3680:2008 Determination of flash/no flash point – Rapid equilibrium closed cup method
- OS GSO ISO 3680:2008 Determination of flash/no flash point – Rapid equilibrium closed cup method
RU-GOST R
- GOST R 59683-2021 Petroleum products. Standard test methods for flash point by continuously closed cup tester
AENOR
- UNE 7155:1961 DETERMINATION IN OPEN CRUCIBLE OF IGNITABLE VOLATILE MATERIALS AND CUTBASKS FLASH POINT. "TAGLIAUBUE OPEN CRUCIBLE METHOD".
- UNE 48061:1985 DETERMINATION OF FLASHPOINT. CLOSED CUP METHOD
Korean Agency for Technology and Standards (KATS)
- KS M 2010-2023 Testing methods for flash point of crude oil and petroleum products —Determination of flash point — Tag closed cup method
- KS M ISO 2592:2007 Determination of flash and fire points-Cleveland open cup method
- KS M ISO 2719:2003 Determination of flash point-Pensky-Martens closed cup method
- KS M ISO 1523-2023 Determination of flash point-Closed cup equilibrium method
SG-SPRING SG
- SS 5 Pt.B15-1987 Methods Of Test For Paints, Varnishes And Related Materials Part B15 : Determination Of Flashpoint-Closed Cup Equilibrium Method
TH-TISI
- TIS 1294-1995 Standard test method for flash point of cutback asphalt with tag open-cup
KR-KS
- KS M ISO 2719-2017 Determination of flash point — Pensky-Martens closed cup method