Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)

Dielectric loss resistivity

Dielectric loss resistivity, Total:38 items.

The international standard classification for "Dielectric loss resistivity" includes: Insulating gases , Other insulating materials , Insulating materials in general , Other standards related to electricity and magnetism .

The Chinese standard classification for "Dielectric loss resistivity" includes: Electrical insulating material and its products .


General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

  • GB/T 5654-2007 Insulating liquids - Measurement of relative permittivity dielectric dissipation factor(tanδ)and d.c. resistivity
  • GB/T 5654-1985 Measurement of relative permittivity,dielectric dissipation factor at power frequency and volume resistivity of insulating liquids
  • GB/T 31838.8-2024 Solid insulating materials—Dielectric and resistive properties—Part 8:Determination of dielectric properties(AC method)—Relative permittivity and dielectric dissipation factor(frequencies 1 MHz~300 MHz)

National Metrological Technical Specifications of the People's Republic of China

  • JJF 1618-2017 Calibration Specification for Insulating Oil Dielectric Dissipation Factor and Volume Resistivity Testers

国家市场监督管理总局、中国国家标准化管理委员会

  • GB/T 31838.6-2021 Solid insulating materials—Dielectric and resistive properties—Part 6:Dielectric properties(AC method)—Relative permittivity and dielectric dissipation factor(frequencies 0.1Hz~10 MHz)

Association Francaise de Normalisation

  • NF C27-210:1979 Measurement of relative permittivity dielectric dissipation factor and D.C. Resistivity of insulating liquids.
  • NF C27-210*NF EN 60247:2004 Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan delta) and d.c.resistivity
  • NF EN 60247:2004 Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan delta) and DC resistivity

SCC

  • DANSK DS/EN 60247:2004 Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan phi) and d.c. resistivity
  • CEI EN 60247:2004 Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan δ) and d.c. resistivity
  • BS 5737:1979 Method for the measurement of relative permittivity, dielectric dissipation factor and d.c. resistivity of insulating liquids

ES-UNE

  • UNE-EN 60247:2004 ERRATUM:2005 Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan d) and d.c. resistivity

International Electrotechnical Commission (IEC)

  • IEC 60247:1978 Measurement of relative permittivity, dielectric dissipation factor and d.c. resistivity of insulating liquids
  • IEC 60247:2004 Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan ) and d.c. resistivity

German Institute for Standardization

  • DIN EN 60247:2005 Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan ) and d.c. resistivity (IEC 60247:2004); German version EN 60247:2004
  • DIN 57472-505:1983 Testing of cables, wires and flexible cords; loss factor, dielectric loss coefficient and leakance [VDE Specification]

Danish Standards Foundation

  • DS/EN 60247:2004 Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan phi) and d.c. resistivity
  • DS/IEC 247:1979 Measurement of relative permittivity, dielectric dissipation factor and d.c. resistivity of insulating liquids

GSO

  • OS GSO IEC 60247:2015 Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan d) and d.c. resistivity
  • GSO IEC 60247:2015 Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan d) and d.c. resistivity

AENOR

  • UNE-EN 60247:2004 Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan d) and d.c. resistivity

British Standards Institution (BSI)

  • BS EN 60247:2004 Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan ) and d.c. resistivity

RU-GOST R

  • GOST R IEC 60247-2013 Insulating liquids. Measurement of relative permittivity, dielectric dissipation factor (tan d) and d.c. resistivity
  • GOST 26127-1984 Electrical insulating paper. Method for determination of the dielectric loss tangent at 50 Hz frequency

Lithuanian Standards Office

  • LST EN 60247-2004 Insulating liquids. Measurement of relative permittivity, dielectric dissipation factor (tan ) and d.c. resistivity (IEC 60247:2004)

European Committee for Electrotechnical Standardization(CENELEC)

  • EN 60247:2004 Insulating liquids Measurement of relative permittivity, dielectric dissipation factor (tan $) and d.c. resistivity

VDE - VDE Verlag GmbH@ Berlin@ Germany

  • VDE 0380-2-2005 Insulating liquids - Measurement of relative permittivity@ dielectric dissipation factor (tan δ) and d.c. resistivity (IEC 60247:2004); German version EN 60247:2004
  • VDE 0472-505-1983 Testing of cables@ wires and flexible cords; loss factor@ dielectric loss coefficient and leakance [VDE Specification]

Standard Association of Australia (SAA)

  • AS 1767.2.2:2008 Test method for insulating liquids Measurement of relative permittivity, dielectric dissipation factor (tan d) and DC resistivity

RO-ASRO

  • STAS 6799-1981 INSULATING MINERAL OILS Determinations of the permittivity and of the dielectric loss tangent
  • STAS 2740-1969 Electrical insulation materials. Determination of dielectric constant and dielectric loss angle

CZ-CSN

  • CSN 34 6466-1983 Methods of test for the determination of the permittivity and dielectric dissipation factor of electrical insulating materials
  • CSN 34 6317-1984 Testing of ceramic electrotechnic materials.Method of the determination of the permitivity and dielectric dissipation factor

KR-KS

  • KS C IEC 62631-2-1-2020 Dielectric and resistive properties of solid insulating materials —Part 2-1: Relative permittivity and dissipation factor —Technical frequencies(0.1 Hz ~ 10 MHz) — AC methods

Korean Agency for Technology and Standards (KATS)

  • KS C IEC 62631-2-1:2020 Dielectric and resistive properties of solid insulating materials —Part 2-1: Relative permittivity and dissipation factor —Technical frequencies(0.1 Hz ~ 10 MHz) — AC methods

American Society for Testing and Materials (ASTM)

  • ASTM D2149-97(2004) Standard Test Method for Permittivity (Dielectric Constant) And Dissipation Factor Of Solid Ceramic Dielectrics At Frequencies To 10 MHz And Temperatures To 500&176C
  • ASTM D2149-97 Standard Test Method for Permittivity (Dielectric Constant) And Dissipation Factor Of Solid Ceramic Dielectrics At Frequencies To 10 MHz And Temperatures To 500176C

Indonesia Standards

  • SNI 04-6542-2001 Measuremert of relative permitivity, dielectric dissipation factor and d.c. resistivity of insulating liquid