Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)

glass pin

glass pin, Total:394 items.

The international standard classification for "glass pin" includes: Materials for the reinforcement of composites , Medical Sciences and health care facilities in general , Interface and interconnection equipment , Other standards related to analytical chemistry , Plugs, socket-outlets, couplers , Other standards related to lamps , Doors and windows .

The Chinese standard classification for "glass pin" includes: Glass fibre , Marking, packaing, transport and storage , Data information , Industrial technical glass , Connector , Electric lighting in general , Fibre reinforced composites , Plastic components and accessorie .


Professional Standard - Building Materials

Professional Standard - Pharmaceutical Packaging

  • YBB 0006-2004 Yuguanfeng Zhuseqiyong Pengguiboli Zhengguan Borosilicate glass barrels for injectables for prefilled syringes

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

  • GB/T 9952-1988 Data communication--15 pin DTE/DCE interface connector and pin assignments
  • GB/T 9951-1988 Data communication--34pin DTE/DCE interface connector and pin assignments
  • GB 15763.1-2001 Safety glazing materials in building Fire-resistant glass
  • GB/T 9950-1988 Data communication-37 pin and 9 pin DTE/DCE interface connectors and pin assignments
  • GB/T 15244-2002 Quantitative analysis of glass by electron probe microanalysis

未注明发布机构

  • DIN EN 13022-1:2006 Glass in building - Structural sealant glazing - Part 1: Glass products for structural sealant glazing systems for supported and unsupported monolithic and multiple glazing
  • DIN ISO 13926-1 E:2018-03 Pen systems - Part 1: Glass cylinders for pen-injectors for medical use
  • DIN EN ISO 12543-2 E:2020-02 Architectural glass Laminated glass and laminated safety glass Part 2: Laminated safety glass (draft)
  • DIN EN ISO 12543-2:2022 Glass in construction – Laminated glass and laminated safety glass – Part 2: Laminated safety glass (ISO 12543-2:2021)
  • DIN EN ISO 12543-3:2022 Glass in construction – Laminated glass and laminated safety glass – Part 3: Laminated glass
  • DIN EN ISO 12543-3 E:2020-02 Laminated glass and laminated safety glass for glass construction Part 3: Laminated glass (draft)
  • DIN EN ISO 12543-6:2011 Glass in building - Laminated glass and laminated safety glass - Part 6: Appearance
  • DIN EN ISO 12543-2:1988 Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass
  • DIN ISO 13926-1:2020-02 Pen systems - Part 1: Glass cylinders for pen-injectors for medical use
  • DIN EN ISO 12543-2 E:2002-12 Architectural glass Laminated glass and laminated safety glass Part 2: Laminated safety glass (draft)
  • DIN 52327-1:1997 Testing of glass; determination of stresses in glass-to-glass sealings
  • DIN EN ISO 12543-3:1998 Laminated glass and laminated safety glass DIN Part 3: Laminated glass

Group Standards of the People's Republic of China

工业和信息化部

Professional Standard - Education

Military Standard of the People's Republic of China-General Armament Department

  • GJB 680/54-1994 SMA Series Pin and Socket to N Series Pin and Socket Level 2 Adapters Detailed Specification
  • GJB 680/9-1994 Detailed Specification for C Series Internal Pin to Pin Level 2 Adapters
  • GJB 680/29-1994 Detailed Specification for SMA Series Internal Pin to Pin Level 2 Adapters
  • GJB 8372-2015 Specification for high pressure resistance glass-to-metal seals used on space initiating device
  • GJB 680/5-1994 Detailed Specification for N Series Internal Pin to Pin Level 2 Adapters
  • GJB 680/36-1994 Detailed Specification for TNC Series Internal Pin to Pin Level 2 Adapters
  • GJB 680/15-1994 Detailed Specification for BNC Series Internal Pin to Pin Level 2 Adapters

中华人民共和国国家质量监督检验检疫总局、中国国家标准化管理委员会

  • GB/T 33826-2017 Measurement of nanofilm thickness on glass substrate-Profilometric method

Professional Standard - Electron

  • SJ 50976/21-2006 Connector coaxial radio frequency series SBMA pin contact flange mounted with EMI gasket and glass seal part for micro-strip detail specification for

Professional Standard - Light Industry

Professional Standard - Construction Industry

Military Standards (MIL-STD)

GM North America

PL-PKN

Electronic Components, Assemblies and Materials Association

  • ECA 337-1967 Glass Coated Thermistor Beads and Thermistor Beads in Glass Probes and Glass Rods (Negative Temperature Coefficient), General Spec. for

SCC

  • HOLDEN HN 1248-2009 PLASTIC INSERT WINDSCREEN CHANNEL
  • NS 5509:1978 Thermometers — Glass inserts for industrial thermometers
  • BS EN ISO 12543-3:1998 Glass in building. Laminated glass and laminated safety glass-Laminated glass
  • HB 125-1998 The glass and glazing handbook
  • AENOR UNE 43024:1953 GLASS. SAFETY GLASS. RESISTANCE OF LAMINAR GLASS TO BOILING WATER
  • BS EN 1748-2:1998 Glass in building-Glass ceramics
  • DANSK DS/ISO 12543-3:2022 Glass in building – Laminated glass and laminated safety glass – Part 3: Laminated glass
  • AENOR UNE 43023:1953 GLASS. SAFETY GLASS. INFLUENCE OF HUMIDITY ON LAMINAR GLASS
  • DANSK DS/EN ISO 12543-3:2011 Glass in building – Laminated glass and laminated safety glass – Part 3: Laminated glass
  • SAE AMSG25871-1999 Glass, Laminated, Aircraft Glazing
  • BS 678:1936 Carboys and carboy hampers
  • DANSK DS/ISO 12543-2:2022 Glass in building – Laminated glass and laminated safety glass – Part 2: Laminated safety glass
  • MIL MIL-C-20079H-1987 CLOTH, GLASS; TAPE, TEXTILE GLASS; & THREAD, GLASS & WIRE-REINFORCED GLASS (SUPERSEDING MIL-C-20079G)
  • SAE AMSG25667-1999 Glass, Monolithic, Aircraft Glazing
  • DANSK DS/EN ISO 12543-2:2011 Glass in building – Laminated glass and laminated safety glass – Part 2: Laminated safety glass
  • AENOR UNE 43013:1970 Glass. Terminology of glass defects.
  • AENOR UNE 43025:1970 Glass. Safety glass. Torsion breakage.
  • NS-EN ISO 12543-3:2011 Glass in building — Laminated glass and laminated safety glass — Part 3: Laminated glass (ISO 12543-3:2011)
  • UNE 126102:2004 Glass containers. Glass terminology. Dimensional relation ships for a normal glass container.
  • NS 5507:1978 Thermometers — Industrial thermometers with glass inserts — V-shaped case
  • AENOR UNE-EN ISO 12543-3:2011 Glass in building - Laminated glass and laminated safety glass - Part 3: Laminated glass (ISO 12543-3:2011)
  • 08/30170598 DC BS EN ISO 12543-3. Glass in building. Laminated glass and laminated safety glass. Part 3. Laminated glass
  • AENOR UNE 43021:1953 GLASS. SAFETY GLASS. BREAKAGE DUE TO THE IMPACT OF A BALL ON REINFORCED GLASS
  • NS-EN ISO 12543-3:1998 Glass in building — Laminated glass and laminated safety glass — Part 3: Laminated glass (ISO 12543-3:1998)
  • NS-EN ISO 12543-3:2021 Glass in building - Laminated glass and laminated safety glass - Part 3: Laminated glass (ISO 12543-3:2021)
  • BS EN ISO 12543-6:1998 Glass in building. Laminated glass and laminated safety glass-Appearance
  • DANSK DS/EN 1279-4:2018 Glass in Building – Insulating Glass Units – Part 4: Methods of test for the physical attributes of edge seal components and inserts
  • BS 952:1964 Classification Glass for glazing and terminology for work on glass
  • NS-EN 572-2:2004 Glass in Building — Basic soda lime slicate glass products — Part 2: Float glass
  • BS EN 1748-1:1998 Glass in building-Borosilicate glasses
  • NS-EN 1279-4:2018 Glass in Building — Insulating Glass Units — Part 4: Methods of test for the physical attributes of edge seal components and inserts
  • AS C317:1958 Four-pin, round-pin plugs and plug sockets (medium voltage, 10-ampere rating)
  • AENOR UNE 43017:1953 GLASS. SAFETY GLASS. RESISTANCE TO THE IMPACT OF A BALL ON SAFETY GLASS, AT NORMAL TEMPERATURE
  • AENOR UNE-EN 1279-4:2019 Glass for buildings. Insulating glass units. Part 4: Test methods for the physical properties of perimeter seals and inserts.
  • AENOR UNE 43018:1953 GLASS. SAFETY GLASS. BREAKAGE DUE TO IMPACT OF A BALL ON SAFETY GLASS, AT NORMAL TEMPERATURE
  • AENOR UNE 43015:1970 Glass. Flat glass. Definitions and terminology.
  • NS-EN ISO 12543-2:2021 Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO 12543-2:2021)
  • AENOR UNE-EN ISO 12543-2:2011 Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO 12543-2:2011)
  • 08/30170594 DC BS EN ISO 12543-2. Glass in building. Laminated glass and laminated safety glass. Part 2. Laminated safety glass
  • UNE 126101:2004 Glass containers. Glass terminology. General.
  • UNE-EN ISO 12543-3:1998 GLASS IN BUILDING. LAMINATED GLASS AND LAMINATED SAFETY GLASS. PART 3: LAMINATED GLASS. (ISO 12543-3:1998).
  • NS-EN ISO 12543-2:2011 Glass in building — Laminated glass and laminated safety glass — Part 2: Laminated safety glass (ISO 12543-2:2011)
  • DIN EN 14449 E:2017 Draft Document - Glass in building - Laminated glass and laminated safety glass - Product standard; German and English version prEN 14449:2017
  • BS EN 572-2:1995 Glass in building. Basic soda lime silicate glass products-Float glass
  • NS-EN ISO 12543-2:1998 Glass in building — Laminated glass and laminated safety glass — Part 2: Laminated safety glass (ISO 12543-2:1998)
  • DANSK DS/EN ISO 12543-6/AC:2011 Glass in building – Laminated glass and laminated safety glass – Part 6: Appearance
  • UNE-EN ISO 12543-2:1998 GLASS IN BUILDING. LAMINATED GLASS AND LAMINATED SAFETY GLASS. PART 2: LAMINATED SAFETY GLASS. (ISO 12543-2:1998).
  • DANSK DS/EN ISO 12543-6:2011 Glass in building – Laminated glass and laminated safety glass – Part 6: Appearance
  • DANSK DS/ISO 12543-6:2022 Glass in building – Laminated glass and laminated safety glass – Part 6: Appearance
  • DANSK DS/EN 14178-1:2004 Glass in building - Basic alkaline earth silicate glass - Part 1: Float glass
  • NS-EN 12488:2016 Glass in building — Glazing recommendations — Assembly principles for vertical and sloping glazing
  • DANSK DS/EN 12488:2016 Glass in building – Glazing recommendations – Assembly principles for vertical and sloping glazing

CZ-CSN

International Organization for Standardization (ISO)

  • ISO 13926-1:2018 Pen systems - Part 1: Glass cylinders for pen-injectors for medical use
  • ISO 13926-1:2004 Pen systems - Part 1: Glass cylinders for pen-injectors for medical use
  • ISO 13926-1:1996 Pen systems - Part 1: Glass cylinders for insulin pen-injectors
  • ISO 12543-3:1998 Glass in building - Laminated glass and laminated safety glass - Part 3: Laminated glass
  • ISO 12543-3:2021 Glass in building — Laminated glass and laminated safety glass — Part 3: Laminated glass
  • ISO 12543-2:2004 Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass
  • ISO 12543-2:2021 Glass in building — Laminated glass and laminated safety glass — Part 2: Laminated safety glass
  • ISO 12543-3:2011 Glass in building - Laminated glass and laminated safety glass - Part 3: Laminated glass
  • ISO 12543-2:2011 Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass
  • ISO 4796:1977 Laboratory glassware; Bottles
  • ISO 12543-6:1998 Glass in building - Laminated glass and laminated safety glass - Part 6: Appearance
  • ISO 25537:2008 Glass in building - Silvered, flat-glass mirror
  • ISO 12543-6:2021 Glass in building — Laminated glass and laminated safety glass — Part 6: Appearance

American Society for Testing and Materials (ASTM)

  • ASTM D468-46 Methods of Testing Pin-Type, Lime-Glass Insulators
  • ASTM D879-62 Specification for Communication and Signal Pin-Type Lime-Glass Insulators
  • ASTM D87-87(1999) Standard Test Method for Melting Point of Petroleum Wax (Cooling Curve)
  • ASTM E911-98(2009) Standard Specification for Glass Stopcocks with Polytetrafluoroethylene (PTFE) Plugs
  • ASTM C162-05(2015) Standard Terminology of Glass and Glass Products
  • ASTM E911-98(2004) Standard Specification for Glass Stopcocks with Polytetrafluoroethylene (PTFE) Plugs
  • ASTM C162-05 Standard Terminology of Glass and Glass Products
  • ASTM C162-04 Standard Terminology of Glass and Glass Products
  • ASTM C162-03 Standard Terminology of Glass and Glass Products

German Institute for Standardization

  • DIN ISO 13926-1:2005 Pen systems - Part 1: Glass cylinders for pen-injectors for medical use (ISO 13926-1:2004), text in German and English
  • DIN 11525:1992 Horticultural glass; horticultural sheet glass and horticultural cast glass
  • DIN EN 14449:2017-12 Glass in building - Laminated glass and laminated safety glass - Product standard; German and English version prEN 14449:2017 / Note: Date of issue 2017-11-10*Intended as replacement for DIN EN 14449 (2005-07).
  • DIN EN ISO 12543-2:2006 Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO 12543-2:1998)(includes Amendment A1:2004); English version of DIN EN ISO 12543-2:2006-03
  • DIN EN 1063:2000 Glass in building - Security glazing - Testing and classification of resistance against bullet attack; German version EN 1063:1999
  • DIN 52327-1:1977 Testing of glass; determination of stresses in glass-to-glass sealings
  • DIN EN ISO 12543-3:2022-03 Glass in building - Laminated glass and laminated safety glass - Part 3: Laminated glass (ISO 12543-3:2021); German version EN ISO 12543-3:2021
  • DIN EN 1279-4:2018-10 Glass in building - Insulating glass units - Part 4: Methods of test for the physical attributes of edge seal components and inserts; German version EN 1279-4:2018
  • DIN EN 14449:2017 Glass in building - Laminated glass and laminated safety glass - Product standard; German and English version prEN 14449:2017
  • DIN EN ISO 12543-2:2022-03 Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO 12543-2:2021); German version EN ISO 12543-2:2021
  • DIN 52341:1993 Testing of glass; chemical analysis of lead crystal glass and crystal glass
  • DIN 52296:1989 Glass and glass ceramics; hydrolytic resistance of the surface of glass and glass ceramic plates at 98 °C; method of test and classification
  • DIN EN 572-5:2004 Glass in building - Basic soda lime silicate glass products - Part 5: Patterned glass; German version EN 572-5:2004
  • DIN 52307:1990-03 Dart drop test on safety glass for vehicle glazing
  • DIN 1259-2:2001 Glass - Part 2: Terminology of glass products
  • DIN 12622:1981 Laboratory glassware; marking of glass instruments for the determination of type of glass
  • DIN EN 12488:2016-11 Glass in building - Glazing recommendations - Assembly principles for vertical and sloping glazing; German version EN 12488:2016

ECIA - Electronic Components Industry Association

  • 337-1967 Glass Coated Thermistor Beads and Thermistor Beads in Glass Probes and Glass Rods (Negative Temperature Coefficient)@ General Spec. for

Korean Agency for Technology and Standards (KATS)

YU-JUS

  • JUS B.E0.001-1987 Glass, vvast and worm glass. Classification, signffication and storage of wast and worm glass

RU-GOST R

Building Officials and Code Administrators International(U.S.)

US-FCR

Defense Logistics Agency

NO-SN

  • NS 5509-1978 Thermometers - Glass inserts for industrial thermometers
  • NS 5507-1978 Thermometers - Industrial thermometers with glass inserts - V-shaped case

CO-ICONTEC

US-AAMA

British Standards Institution (BSI)

  • BS EN ISO 12543-2:1998 Glass in building - Laminated glass and laminated safety glass - Laminated safety glass
  • BS EN ISO 12543-3:2021 Glass in building. Laminated glass and laminated safety glass. Laminated glass
  • BS EN ISO 12543-3:2011 Glass in building. Laminated glass and laminated safety glass. Laminated glass
  • BS EN ISO 12543-2:2011 Glass in building. Laminated glass and laminated safety glass. Laminated safety glass
  • BS 952-2:1980(1999) Glass for glazing — Part 2 : Terminology for work on glass
  • BS EN ISO 12543-2:2021 Glass in building. Laminated glass and laminated safety glass - Laminated safety glass
  • BS EN 1279-4:2018 Glass in Building. Insulating Glass Units. Methods of test for the physical attributes of edge seal components and inserts
  • BS EN 572-5:1995 Glass in building - Basic soda lime silicate glass products - Patterned glass
  • BS EN 1051-1:2003 Glass in building - Glass blocks and glass pavers - Definitions and description
  • BS EN 572-5:2012 Glass in building. Basic soda lime silicate glass products. Patterned glass
  • BS EN 572-2:2004 Glass in building - Basic soda lime silicate glass products - Float glass
  • BS EN 572-2:2012 Glass in building. Basic soda lime silicate glass products. Float glass
  • BS EN 572-5:2004 Glass in building - Basic soda lime silicate glass products - Patterned glass
  • BS EN ISO 12543-6:2021 Glass in building. Laminated glass and laminated safety glass. Appearance
  • BS EN 13022-1:2006 Glass in building - Structural sealant glazing - Glass products for structural sealant glazing systems for supported and unsupported monolithic and multiple glazing
  • BS EN 572-4:2004 Glass in building - Basic soda lime silicate glass products - Drawn sheet glass
  • BS EN 572-3:2012 Glass in building. Basic soda lime silicate glass products. Polished wired glass
  • BS EN 572-4:1995 Glass in building - Basic soda lime silicate glass products - Drawn sheet glass
  • BS EN ISO 12543-6:2011 Glass in building. Laminated glass and laminated safety glass. Appearance
  • BS EN 14178-1:2004 Glass in building - Basic alkaline earth silicate glass - Float glass
  • BS EN 572-6:2004 Glass in building - Basic soda lime silicate glass products - Wired patterned glass
  • BS EN 572-3:1995 Glass in building - Basic soda lime silicate glass products - Polished wired glass
  • BS EN 572-6:1995 Glass in building - Basic soda lime silicate glass products - Wired patterned glass
  • BS EN 1288-4:2000 Glass in building - Determination of the bending strength of glass - Testing of channel shaped glass
  • BS EN 572-3:2004 Glass in building - Basic soda lime silicate glass products - Polished wire glass
  • BS ISO 12818:2013 Glass packaging. Standard tolerances for flaconnage
  • BS EN 1051-2:2008 Glass in building - Glass blocks and glass pavers - Evaluation of conformity/Product standard
  • BS EN 13022-1:2014 Glass in building. Structural sealant glazing. Glass products for structural sealant glazing systems for supported and unsupported monolithic and multiple glazing
  • BS 952-1:1995(2008) Glass for glazing — Part 1 : Classification
  • 20/30402975 DC BS EN ISO 12543-3. Glass in building. Laminated glass and laminated safety glass. Part 3. Laminated glass
  • BS ISO 11485-2:2012 Glass in building. Curved glass. Quality requirements
  • BS EN 1051-2:2007 Glass in building — Glass blocks and glass pavers — Part 2: Evaluation of conformity/Product standard
  • BS EN 572-6:2012 Glass in building. Basic soda lime silicate glass products. Wired patterned glass

U.S. Air Force

Association Francaise de Normalisation

  • NF P78-302:1985 Glazing and mirrors. Polished plate glass for glazing for buildings.
  • NF P78-211-3*NF EN ISO 12543-3:2021 Glass in building - Laminated glass and laminated safety glass - Part 3 : laminated glass
  • NF P78-211-3:2011 Glass in building - Laminated glass and laminated safety glass - Part 3 : laminated glass.
  • NF EN ISO 12543-3:2021 Glass in construction - Laminated glass and laminated safety glass - Part 3: laminated glass
  • NF P78-301:1985 Glazing and mirrors. Sheet glass for glazing for buildings.
  • NF P78-211-2*NF EN ISO 12543-2:2021 Glass in building - Laminated glass and laminated safety glass - Part 2 : laminated safety glass
  • NF P78-212:1998 Glass in building. Laminated glass and laminated safety glass. Part 2 : laminated safety glass.
  • NF P78-212/A1:2005 Glass in building - Laminated glass and laminated safety glass - Part 2 : laminated safety glass.
  • NF P78-211-2:2011 Glass in building - Laminated glass and laminated safety glass - Part 2 : laminated safety glass.
  • NF EN ISO 12543-2:2021 Glass in construction - Laminated glass and laminated safety glass - Part 2: laminated safety glass
  • NF P78-474*NF EN 1279-4:2018 Glass in Building - Insulating glass units - Part 4 : methods of test for the physical attributes of edge seal components and inserts
  • NF EN 1051-1:2003 Glass in construction - Glass blocks and glass slabs - Part 1: definitions and descriptions
  • NF P78-211-6*NF EN ISO 12543-6:2021 Glass in building - Laminated glass and laminated safety glass - Part 6 : appearance
  • NF P78-701-1*NF EN 13022-1:2014 Glass in building - Structural sealant glazing - Part 1 : Glass products for structural sealant glazing systems for supported and unsupported monolithic and multiple glazing
  • NF P78-211-6:2011 Glass in building - Laminated glass and laminated safety glass - Part 6 : appearance.
  • NF P78-303:1980 Laminated glass for building glazing.
  • NF P78-341*NF EN 1288-1:2000 Glass in building - Determination of the bending strength of glass - Part 1 : fundamentals of testing glass.
  • NF P78-701-1/IN1:2010 Glass in building - Structural sealant glazing - Part 1 : glass products for structural sealant glazing systems for supported and unsupported monolithic and multiple glazing.
  • NF P78-701-1:2010 Glass in building - Structural sealant glazing - Part 1 : glass products for structural sealant glazing systems for supported and unsupported monolithic and multiple glazing.
  • NF P78-304:1980 TOUGHENED GLASS FOR BUILDING GLAZING.
  • NF P78-213:1998 Glass in building. Laminated glass and laminated safety glass. Part 3 : laminated glass.
  • NF EN 572-4:2013 Glass in construction - Commodities: soda-lime silicate glass - Part 4: drawn glass
  • NF EN ISO 12543-6:2021 Glass in construction - Laminated glass and laminated safety glass - Part 6: appearance
  • NF P78-104:1995 Glass in building. Basic soda lime silicate glass products. Part 3 : polisched wired glass.
  • NF EN 14178-1:2005 Glass in Construction - Basic Alkaline Earth Silicate Glass - Part 1: Float Ice
  • NF EN 572-5:2013 Glass in construction - Commodities: soda-lime silicate glass - Part 5: printed glass
  • NF H35-096:1991 Bottling industry. Glass bottles. Glass finishes, low form.

GM Europe

  • GME STD 518364-1995 Glass 8364 Laminated glass. Float and mirror glass Glas 8364 Lamellglas. Float- och spegelglas English/Swedish
  • GME STD 518365-1995 Glass 8365 Toughened glass. Float and mirror glass Glas 8365 F鰎sp鋘t glas (h鋜dat). Float- och spegelglas English/Swedish
  • GME STD 518858-2002 Glass 8858 Heat absorbing laminated/toughened float glass Glas 8858 V鋜meabsorberande laminerat/h鋜dat floatglas English/Swedish
  • GME STD 518785-1996 Glass 8785 Mirror glass Glas 8785 Spegelglas English/Swedish

RO-ASRO

IT-UNI

AT-ON

GSO

  • GSO ISO 12543-3:2024 Glass in building — Laminated glass and laminated safety glass — Part 3: Laminated glass
  • BH GSO ISO 12543-3:2013 Glass in building- Laminated glass and laminated safety glass – Part 3: Laminated glass.
  • OS GSO ISO 12543-3:2012 Glass in building- Laminated glass and laminated safety glass – Part 3: Laminated glass.
  • GSO ISO 12543-2:2024 Glass in building — Laminated glass and laminated safety glass — Part 2: Laminated safety glass
  • OS GSO ISO 12543-2:2012 Glass in building- Laminated glass and laminated safety glass – Part 2: Laminated safety glass
  • GSO ISO 12543-3:2012 Glass in building- Laminated glass and laminated safety glass – Part 3: Laminated glass.
  • BH GSO ISO 12543-2:2013 Glass in building- Laminated glass and laminated safety glass – Part 2: Laminated safety glass
  • GSO ISO 4790:2010 Glass-to-glass sealings -- Determination of stresses
  • GSO ISO 12543-2:2012 Glass in building- Laminated glass and laminated safety glass – Part 2: Laminated safety glass
  • GSO EN 1279-4:2021 Glass in Building - Insulating Glass Units – Part 4: Methods of test for the physical attributes of edge seal components and inserts
  • BH GSO EN 1279-4:2022 Glass in Building - Insulating Glass Units – Part 4: Methods of test for the physical attributes of edge seal components and inserts
  • GSO ISO 12543-6:2024 Glass in building — Laminated glass and laminated safety glass — Part 6: Appearance
  • BH GSO ISO 12543-6:2013 Glass in building - Laminated glass and laminated safety glass – Part 6: Appearance.
  • OS GSO ISO 12543-6:2012 Glass in building - Laminated glass and laminated safety glass – Part 6: Appearance.

European Committee for Standardization (CEN)

  • EN ISO 12543-3:2011 Glass in building - Laminated glass and laminated safety glass - Part 3: Laminated glass (ISO 12543-3:2011)
  • EN ISO 12543-3:2021 Glass in building - Laminated glass and laminated safety glass - Part 3: Laminated glass (ISO 12543-3:2021)
  • EN 572-2:2012 Glass in building - Basic soda lime silicate glass products - Part 2: Float glass
  • EN 572-2:1994 Glass in Building - Basic Soda Lime Silicate Glass Products - Part 2: Float Glass
  • EN ISO 12543-2:2011 Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO 12543-2:2011)
  • EN ISO 12543-2:2021 Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO 12543-2:2021)
  • EN ISO 12543-3:1998 Glass in Building - Laminated Glass and Laminated Safety Glass - Part 3: Laminated Glass ISO 12543-3:1998
  • EN ISO 12543-6:2011 Glass in building - Laminated glass and laminated safety glass - Part 6: Appearance (Incorporating corrigendum May 2012)
  • EN ISO 12543-6:2021 Glass in building - Laminated glass and laminated safety glass - Part 6: Appearance (ISO 12543-6:2021)
  • FprEN ISO 12543-3:2021 Glass in building - Laminated glass and laminated safety glass - Part 3: Laminated glass (ISO/FDIS 12543-3:2021)
  • EN 572-3:2012 Glass in building - Basic soda lime silicate glass products - Part 3: Polished wired glass
  • EN 572-6:1994 Glass in Building - Basic Soda Lime Silicate Glass Products - Part 6: Wired Patterned Glass
  • EN 572-6:2012 Glass in building - Basic soda lime silicate glass products - Part 6: Wired patterned glass
  • EN 572-3:1994 Glass in Building - Basic Soda Lime Silicate Glass Products - Part 3: Polished Wire Glass
  • EN 12488:2016 Glass in building - Glazing recommendations - Assembly principles for vertical and sloping glazing
  • EN 572-2:2004 Glass in Building - Basic soda lime silicate glass products - Part 2: Float glass
  • FprEN ISO 12543-2:2021 Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO/FDIS 12543-2:2021)
  • EN 572-5:1994 Glass in Building - Basic Soda Lime Silicate Glass Products - Part 5: Patterned Glass
  • EN 572-5:2012 Glass in building - Basic soda lime silicate glass products - Part 5: Patterned glass

Society of Automotive Engineers (SAE)

Indonesia Standards

  • SNI ISO 12543-3:2011 Glass in building - Laminated glass and laminated safety glass - Part 3: Laminated glass
  • SNI ISO 12543-2:2011 Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass

VN-TCVN

DIN

Danish Standards Foundation

TH-TISI

SAE - SAE International

ES-UNE

  • UNE-EN ISO 12543-3:2022 Glass in building - Laminated glass and laminated safety glass - Part 3: Laminated glass (ISO 12543-3:2021)
  • UNE-EN 1279-4:2019 Glass in Building - Insulating Glass Units - Part 4: Methods of test for the physical attributes of edge seal components and inserts
  • UNE-EN ISO 12543-2:2022 Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO 12543-2:2021)
  • UNE-EN ISO 12543-6:2022 Glass in building - Laminated glass and laminated safety glass - Part 6: Appearance (ISO 12543-6:2021)

BE-NBN

CEN - European Committee for Standardization

  • EN ISO 12543-2:1998 Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass
  • PREN 14449-2017 Glass in building - Laminated glass and laminated safety glass - Product standard
  • EN 572-5:2004 Glass in Building - Basic Soda Lime Silicate Glass Products - Part 5: Patterned Glass
  • EN 572-3:2004 Glass in Building - Basic Soda Lime Silicate Glass Products - Part 3: Polished Wire Glass
  • EN 572-6:2004 Glass in Building - Basic Soda Lime Silicate Glass Products - Part 6: Wired Patterned Glass

ES-AENOR

  • UNE 43 023 Glass. Safety glass, effect of humidity on pressed glass
  • UNE 43 024 Glass. Safety glass, pressed glass resistance to boiling water
  • UNE 43-404-1986 Glass tube. Glass bubble definition and specifications
  • UNE 43-508-1985 glass fiber. Textile glass, determination of tensile rupture force of textile glass mats
  • UNE 43 021 Glass. Safety glass, armored glass broken by impact of a ball
  • UNE 43-401-1985 Glass tube. Glass fittings, pipes and connections, glass properties of borosilicate 3.3
  • UNE 43 019 Glass. Safety glass, impact resistance of a ballast bag on armored glass
  • UNE 43 009 Glass. Flat glass, safety test of flat glass, flatness test

SE-SIS

NL-NEN

HU-MSZT

AENOR

  • UNE-EN ISO 12543-3:2011 Glass in building - Laminated glass and laminated safety glass - Part 3: Laminated glass (ISO 12543-3:2011)
  • UNE 43404:1997 GLASS TUBING. GLASS-BUBBLES. DIMENSIONS AND DEFINITIONS.
  • UNE 126101:2011 Glass containers. Glass terminology. General.
  • UNE-EN ISO 12543-2:2011 Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO 12543-2:2011)
  • UNE-EN 1051-1:2003 Glass in building - Glass blocks and glass pavers - Part 1: Definitions and description

PT-IPQ

  • NP 1904-1986 Glass. Crystal glass and bright glass classification, characteristics, labeling

Japanese Industrial Standards Committee (JISC)

Institute of Interconnecting and Packaging Electronic Circuits (IPC)

U.S. Military Regulations and Norms

Lithuanian Standards Office

  • LST EN ISO 12543-3:2011 Glass in building - Laminated glass and laminated safety glass - Part 3: Laminated glass (ISO 12543-3:2011)
  • LST EN ISO 12543-2:2011 Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO 12543-2:2011)

CU-NC

  • NC 46-05-1986 Glass. Glass Bottle for Lactation Quality Specifications