Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
control rules scopethis section specifies air dryer
DL/T 1819-2018 in English

DL/T 1819-2018 in English

VALID

Specification of static frequency converter for pumped storage power plant

  • Issued on:2018-04-03
  • Implemented on:2018-07-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $180.00
$175.00
Standard No: DL/T 1819-2018
Document status: VALID
Title in English: Specification of static frequency converter for pumped storage power plant
Title in Chinese: 抽水蓄能电站静止变频装置技术条件
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2018-04-03
Implemented on: 2018-07-01
Professional Classification: DL-Electricity
Related Topics: power station
Static Elimination Device
Denaturing conditions Non-denaturing conditions
Static setting 5sec
qPCR instrument installation conditions
Smart substation measurement device control technology
Completion acceptance of pumped storage power station
Acceptance of pumped storage power station
Construction supervision of pumped storage power station
Soil and Water Conservation Technology for Pumped Storage Power Station


Introduction

Analysis of the Standard Technical Framework

Core Module Technology from the 1990s DL/T1819-2018 Requirements Technological Evolution
Cooling System Single Air Cooling Method Air Cooling/Water Cooling Dual Modes, Water Cooling Conductivity <2μS/cm Thermal Management Accuracy Improved by 300%
Electromagnetic Compatibility No System-Level Standard Appendix A Clarifies the Immunity Levels for Category 4 Ports Establish a Complete EMC Protection System
Startup reliability Single startup success rate ≤95% Annual success rate ≥99%, availability ≥99.9% O&M costs reduced by 40%

Detailed explanation of key technical indicators

Environmental adaptability: The standard requires that the thyristor valve water-cooling temperature limit for static frequency converters at an altitude of ≤1000m must be +5°C for water cooling and -5°C for air cooling. A typical case study shows that the Zhanghewan Power Station, by adding a preheating module, ensures that the equipment still meets startup requirements in an environment of -15°C.

Dynamic performance: The output frequency is continuously adjustable from 0-52.5Hz, with a control accuracy of ±0.05Hz. Measured data from the Tongbai Power Station shows that this indicator can shorten the unit's grid connection time to 2.3 minutes (the standard requirement is ≤5 minutes).


Implementation Recommendations

  1. When selecting the input transformer, a 20% harmonic tolerance margin should be reserved, and temperature rise verification should be carried out in accordance with GB/T18494.
  2. It is recommended to adopt a 12-pulse structure to reduce input-side harmonics to below 60% of the GB/T14549 limit.
  3. Electromagnetic compatibility testing must include three mandatory inspection items: radio frequency field immunity (10V/m), electrostatic discharge (8kV), and surge impact (2kV).

Background of Standard Development

With the single-unit capacity of pumped-storage units exceeding 400MW, traditional frequency conversion devices have exposed obvious shortcomings in start-up success rate and electromagnetic interference. This standard unified for the first time: ① the n+1 redundancy principle for thyristor valves ② the dual cooling system configuration requirements ③ the four-level power frequency magnetic field immunity standard (300A/m), filling a gap in the industry.

Sample only — not a preview of DL/T 1819-2018
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • DL/T 790.12-2001 in English

    DL/T 790.12-2001 in English

    Distribution Automation Using Distribution Line Carrier Part 1: General Provisions Part 2: Guidelines for Formulation of Specifications

    2001-12-26
  • DL/T 681.1-2019 in English

    DL/T 681.1-2019 in English

    Specification for wear-rear-resistant parts of coal mill in coal-fired power plants-Part 1:Ball grinding mill,grinding balls and liner

    2019-06-04
  • DL 5073-1997 in English

    DL 5073-1997 in English

    Code for seismic design of hydraulic structures

    1997-08-04