Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
vacuum circuit-breakers hv vacuum circuit-breaker hv vacuum circuit-breakers fitted vacuum interrupters single-phase hv vacuum circuit-breakers clupehead bream fry non-radiolabeled immunoassay kits concrete construction control
DL/T 403-2000 in English

DL/T 403-2000 in English

ABOLISHED

HV vacuum circuit-breaker for rated voltage 12kv to 40.5kv

  • Issued on:2000-11-03
  • Implemented on:2001-01-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $170.00
$165.00
Standard No: DL/T 403-2000
Document status: ABOLISHED
Superseded by: DL/T 403-2017 High-voltage alternating-current vacuum circuit-breaker
Superseded on: 2018-03-01
Title in English: HV vacuum circuit-breaker for rated voltage 12kv to 40.5kv
Title in Chinese: 12kV-40.5kV高压真空断路器订货技术条件
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2000-11-03
Implemented on: 2001-01-01
Superseding: DL/T 403-1991 Indoor HV Vacuum Circuit-Breaker for Rated Voltage 10kv to 35kv
Chinese Classification: K43-High voltage switchgear
Professional Classification: DL-Electricity
Related Keywords: vacuum circuit-breakers
hv vacuum circuit-breaker
hv vacuum circuit-breakers
fitted vacuum interrupters
single-phase hv vacuum circuit-breakers
Related Topics: dl2000
dl-2000
Circuit breaker standard
dl 2000
dl+2000
vacuum
dl2000+
iec62271-100 high voltage circuit breaker
Technical conditions for ordering high-voltage AC circuit breakers
High pressure test technical conditions
vacuum
dl2000dl
dl/t403
dl2000 dl
dl/t 403
broken
Circuit breaker vacuum
vacuum circuit breaker
Vacuum circuit breaker test
breaker
vacuum circuit breaker sf6
Vacuum circuit breaker withstand voltage test
High voltage vacuum short circuit resistance
Vacuum circuit breaker power frequency withstand voltage test
Vacuum circuit breaker opening and closing speed
Foreign vacuum circuit breaker voltage resistance
Disassembly method of vacuum tube of vacuum circuit breaker
Vacuum circuit breaker bounce
High vacuum parts


1 Scope

This standard specifies the service conditions, parameters, structures, technical requirements and test items of HV vacuum circuit-breakers.
This standard is applicable to three-phase and single-phase HV vacuum circuit-breakers (hereinafter referred to as vacuum circuit-breakers) with rated voltage 12kV~40.5kV and frequency 50Hz and their fitted vacuum interrupters (hereinafter referred to as interrupters, also called switching tubes).This product is mainly used for the protection and control in the power plant, AC distribution system and transformer substation as well as such locations as transformer substations of industrial and mining enterprises.
Note: The generator circuit-breaker shall not be included.

2 Normative References

The following normative documents contain provisions which, through reference in this standard, constitute provisions of this standard. At time of publication, the editions indicated were valid. All the standards will be revised, all parties coming to an agreement according to this standard are encouraged to study whether the latest editions of the following standards are applicable.

Foreword I
1 Scope
2 Normative References
3 Normal and Particular Service Requirements
4 Rated Parameters
5 Structural and Technical Requirements
6 Type Tests
7 Delivery Tests
8 Marking, Packaging, Transport and Storage