DL/T 617-2019 in English
VALIDSpecifications for gas-insulated metal-enclosed switchgear
- Issued on:2019-11-04
- Implemented on:2020-05-01
- File Format:PDF
- Delivery:Via email within 10 business days
$1,499.00
| Standard No: | DL/T 617-2019 |
| Document status: | VALID |
| Title in English: | Specifications for gas-insulated metal-enclosed switchgear |
| Title in Chinese: | 气体绝缘金属封闭开关设备技术条件 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 10 business days |
| Issued on: | 2019-11-04 |
| Implemented on: | 2020-05-01 |
| ICS Classification: | 29.130.10-High voltage switchgear and controlgear |
| Chinese Classification: | K43-High voltage switchgear |
| Professional Classification: | DL-Electricity |
| Related Keywords: | special technical specifications
gas-insulated metal-enclosed switchgear introduction analysis special grade d/e technical requirements gas outdoor grade c |
Introduction
Analysis of the core content of the standard
| Technical dimension | DL/T 617-2019 | IEC 62271-203:2011 |
|---|---|---|
| Scope of application | 72.5kV and above | Above 52kV |
| Pollution level | Outdoor grade d (special grade e) | Outdoor grade c (special grade d/e) |
| Pressure system | Newly added locking pressure requirements | Lockout parameters are not specified |
Key technical requirements
Gas sealing system
The standard clearly requires that the annual leakage rate of SF6 gas equipment should be less than 0.5%, and fresh gas must be used for on-site installation. Compared with the 2010 version, the gas purity detection requirement (Clause 10.3.101.10) has been added.
Mechanical characteristics test
The factory test stipulates that the circuit breaker needs to undergo more than 200 mechanical operation tests (Clause 7.102), and measure the travel-time characteristic curve to ensure that the contacts are fully run-in.
Implementation recommendations
- 363kV and above GIS transportation should be equipped with vibration recorders (Clause 10.2)
- Temporary clean rooms are recommended for outdoor installation (Clause 10.3.1)
- Regular verification test cycle ≤ 8 years (Clause 6.1.1)
Technology evolution analysis
This standard incorporates special technical specifications for pot insulators (Appendix C) and insulating pull rods (Appendix E) for the first time, improving the quality control system of core components of GIS equipment. Compared with the IEC standard, 1100kV UHV equipment parameters (Clause 4.3) have been added.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

DL/T 2859-2024 in English
12kV primary and secondary fusion pole switch
2024-12-25 -

DL/T 2932-2025 in English
Guidelines for the Supervision of High Voltage Alternating Current Switchgear Manufacturing
2025-06-30