GA/T 1337-2016 in English
VALIDSecurity requirements for protecting cabins of bank self-service devices
- Issued on:2016-09-08
- Implemented on:2016-10-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
Price(USD):
$220.00
$214.00
$214.00
| Standard No: | GA/T 1337-2016 |
| Document status: | VALID |
| Title in English: | Security requirements for protecting cabins of bank self-service devices |
| Title in Chinese: | 银行自助设备防护舱安全性要求 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 1~3 business days |
| Issued on: | 2016-09-08 |
| Implemented on: | 2016-10-01 |
| ICS Classification: | 13.310-Protection against crime |
| Chinese Classification: | A90-Social and public safety in general |
| Professional Classification: | GA-Security |
| Related Topics: | Equipment Safety Requirements
security requirements equipment ga/t1318-2016 ga/t 2000.141-2016 Equipment Design Security Requirements Self-safety design Device Security Requirements bank equipment ga/t1335-2016 self help Other safety equipment Protective cabin equipment protection GA/T1337 What are the biosafety protection equipment? ga1337-2016 |
本标准规定了银行自助设备防护舱的术语和定义、分类和标记、技术要求、试验方法、检验规则、包装、运输和贮存。
本标准适用于银行自助设备防护舱的设计、制造、安装、检验和验收。
Introduction
Standard core framework
| Technical modules | Key indicators | Test methods |
|---|---|---|
| Cabin structure | Frame steel ≥1.2mm Transparent material transmittance ≥75% | Vernier caliper measurement Spectrophotometer detection |
| Lock system | Mechanical lock compression resistance ≥2500N Electromagnetic lock holding force ≥2500N | Pressure testing machine test Force gauge detection |
| Electrical safety | Insulation resistance ≥ 100MΩ Leakage current ≤ 5mA | Mgohmmeter detection Leakage current tester |
Analysis of key technologies
1. Physical protection system
The standard requires that the protection cabin adopts a double-layer protection structure:
- The frame is made of steel plate/stainless steel plate with a thickness of 1.2mm or above
- Transparent side panels must use laminated glass with a thickness of ≥5mm
- Cabin door gap control ≤5mm (fixed side)
2. Intelligent control system
The standard innovatively proposes the requirement of height sensing linkage:
- Detection of the presence of people with a height ≥1.1m
- Automatic door anti-pinch force 29.4-49N
- Locking response time ≤2s
Implementation Suggestions
1. Model Selection and Configuration Scheme
| Scenario | Recommended Model | Special Requirements |
|---|---|---|
| Outdoor Independent Deployment | FHC-FZ Type | Waterproof Cabin Top + Anti-Rust Treatment |
| Indoor Dense Deployment | FHC-HS Type | Shared Side Panel Translucent Treatment |
2. Acceptance Points
- Focus on checking the locks Key Quantity ≥ 6000
- Test the Concealment of the Emergency Unlocking Device
- Verify the detection accuracy of 1.1m height ±2cm